-A3 ZP3A-T1-B3 ZP3A-T1-A6-B3 ZP3A-T3-A5 ZP3A-T3-B5 Note 1) ; in the table indicates the pad material.
Note 2) Splash proof specification is not available for F and T1.
Time [s] LEC SS-T T1 T2 T3 T4 T1 = V/a1 [s] T3 = V/a2 [s] LEC Y T2: Constant speed time can be found from the following equation.
(For F, L, S, T & T1 kits) D-Side End Plate Assembly 2. U-side end plate assembly part no.
Calculation example) T1 to T4 can be calculated as follows. L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/10 = 0.03 [s], T3 = V/a2 = 300/10 = 0.03 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be found by the following equation.
Calculation example) T1 to T4 can be calculated as follows. L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time [s] T = T1 + T2 + T3 + T4 [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be obtained by the following equation.
01 T1 01 T1 Grommet style/ZSE2-15 Connector style/ZSE2-15C Pressure setting Pressure setting Indicator light Indicator light trimmer trimmer 15 Lead wire length 600 15 (3000) H H L L 20 20 Lead wire length 600 Lead wire length 600 Lead wire length 600 (3000) 9.5 39 8.5 39 8.5 3.5 3.5 3.5 Mounting hole 3.5 Mounting hole 2201: R(PT) 1/8 T1: NPTF1/8 01: R(PT) 1/8 T1: NPTF1/8 M5 X 0.8 Depth
,T2Inverter pump 6.3.1 Option T1, T2Inverter pump With option T1 or T2, the pump output set value can be changed.
Note 2) Splash proof specification is not available for F and T1.
Average suction flow rate V x 60 T1 V x 60 T1 Q = Q = + QL T2 = 3 x T1 T2 = 3 x T1 Q : Average suction flow rate /min (ANR) V : Piping capacity () T1 : Arrival time to stable Pv 63% after adsorption (sec.) T2 : Arrival time to stable Pv 95% after adsorption (sec.) QL : Leakage at work adsorption /min (ANR) 2.
Average suction flow rate V x 60 T1 V x 60 T1 Q = Q = + QL T2 = 3 x T1 T2 = 3 x T1 Q : Average suction flow rate /min (ANR) V : Piping capacity () T1 : Arrival time to stable Pv 63% after adsorption (sec.) T2 : Arrival time to stable Pv 95% after adsorption (sec.) QL : Leakage at work adsorption /min (ANR) 2.
Typ. 7/8 1 5/64 5 8 Hex 3/8 1 3/32 1 7/16 5/8 7/8 11/16 40 1/8 T2 1/2 1/8 T2 1/8 T4 1/8 T6 1/8 T3 1/8 T1 1/8 T5 1/8 T8 1/8 T4-90 1 1/16 Note: Reducing Tees available with other barb combinations #1 7/8 17 32 7 16 7 16 Hex Typ. 27 32 #3 1 3/32 3/4 3/8 Typ. 7/8 9 16 7 16 #2 #4 27/32 3/4 41 1/8 T2 x 3 1/8 RT3 x 1 1/8 T3 x 3 1/8 T1 x 3 1/8 T4 x 3 1/8 RT4 x 2 7/16 7/16 17/32 9/16 19/32
-25 NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ZSE401 T1-26 Vacuum Analog output 1~5V (+ 5%F.S.), load impedance : 1k ZSE401 T1-65 PNP output PNP open collector 80mA ISE4L01 T1-25 Positive Pressure NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ISE4L01 T1-26 100kPa Analog output 1~5V (+ 5%F.S.), load impedance: 1k ISE4L01 T1-65 (14.5PSI) Type
JOG and constant rate movement, return to origin, test drive and testing of forced output can be performed. 569 B LEC Series Teaching Box/LEC-T1 RoHS How to Order LEC T1 3 J G Enable switch (Option) Enable switch Teaching box Nil None S Equipped with enable switch Cable length [m] 3 3 Interlock switch for jog and test function Stop switch Initial language Stop switch J Japanese E English
Adsorption Response Time with the Formula Adsorption response times T1 and T2 can be obtained through the formulas given below.
Determine the mean suction flow: Q r = v x 6 o T1 9 9 0 . s : s : : P o o . g u o.z T 2 = 3 1 o 1 mean suction flow required from ejector (N/min), 0.1 0.2 0.3 0.5 0.7 1 2 3 | 5 7 10 20 30 50 70 100 O T1 i(sec) o1 adsorption response time to 63% to P, (sec), T1 adsorption response time to 95% of P" (sec), T2 1 l lncnnic System Specif ication (continued) 2.
-25 NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ZSE401 T1-26 Vacuum Analog output 1~5V (+ 5%F.S.), load impedance : 1k ZSE401 T1-65 PNP output PNP open collector 80mA ISE4L01 T1-25 Positive Pressure NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ISE4L01 T1-26 100kPa Analog output 1~5V (+ 5%F.S.), load impedance: 1k ISE4L01 T1-65 (14.5PSI) Type
: NPTF 1/8 01: R 1/8 T1: NPTF 1/8 IF Data 16-6-13
Determine the mean suction flow: Q r = v x 6 o T1 9 9 0 . s : s : : P o o . g u o.z T 2 = 3 1 o 1 mean suction flow required from ejector (N/min), 0.1 0.2 0.3 0.5 0.7 1 2 3 | 5 7 10 20 30 50 70 100 O T1 i(sec) o1 adsorption response time to 63% to P, (sec), T1 adsorption response time to 95% of P" (sec), T2 1 l lncnnica System Specif ication (continued) 2.
T1 = V/a1 = 1000/2500 = 0.4 [s], T1 T2 T3 T4 11LEJS T3 = V/a2 = 1000/2500 = 0.4 [s] L: Stroke [mm](Operating condition) V: Speed [mm/s](Operating condition) a1: Acceleration [mm/s2](Operating condition) a2: Deceleration [mm/s2](Operating condition) T = T1 + T2 + T3 + T4 [s] L 0.5V(T1 + T3) V 25AT2 = T1: Acceleration time and T3: Deceleration time can be obtained by the following equation