Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS 2 0 F A 1 1 M5 06 G Body size 1 AS 2 0 S F A 1 2 01 06 G Body size 2/3/4 Body size Made to Order Refer to page 678 for details. 2 1/8, 1/4 3 3/8 4 1/2 Push-lock type Type 2 Elbow 3 Universal Seal method Nil Without sealant S With sealant Note) Face seal method is used for the G thread type.
Dimensions 4 EXH port 1/8 Input signal port( PIL ) R port Supply pressure exhaust port 2 x 1/8 Output port 2( A ) Supply port on the other side 1( P ) 2 x M6 x 1 thread depth 8 (Panel mounting screw) Panel mounted Bracket mounted 2 x 6.5 hole (Mounting screw M6 x 1 x 12) Handle side 4 x M6 screw 4 x 7 hole on the bracket side Bracket plate thickness t = 2 Panel plate thickness t = 3 or less
Dimensions IC PVQ VEF VEP DXT334-X72-04R-04U VER Mounting section (For M8) L side VEA VY2 VBA VBAT U side D side AP100 1 2 2 x Rc Exhaust port R side Rc 1/2 supply port (L side) 2 x Rc 1/2, Output port 709
60 x 41 (mm), 170g (2.4" x 2.4" x 1.6", 6.0 oz) Piping and wiring centralized on one side Air supply port Air exhaust port Switching valve Discharge port Built-in solenoid valve (3 port valve) PB1013 air operated type does not have built-in solenoid valve.
SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70
Alarm_Co mment_1 11 (01-111) 6F C RESET Input
Description Part number Remarks Bracket A ZS-38-A1 Mounting screw (M3 x 5L, 2 pcs.) Bracket B ZS-38-A2 Mounting screw (M3 x 5L, 2 pcs.) Bracket C ZS-38-A3 Mounting screw (M3 x 5L, 2 pcs.) Panel mount adapter ZS-27-C Mounting screw (M3 x 8L, 2 pcs.) Panel mount adapter + Front protective cover ZS-27-D Mounting screw (M3 x 8L, 2 pcs.)
ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Standard pressure: 100 kPa Standard pressure: 100 kPa Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.4 0.6 Standard pressure Standard pressure 0.5 mm 0.25 mm Detection distance (mm) Detection distance (mm) 0.5 0.3 0.4 0.2 0.3 0.15 mm 0.15 mm 0.2 0.1 0.1 0.03 mm 0.01 mm 0 0 50 0 250 200 150 100 250
Setting range: MT.01 to MT.05 (Initial value: MT.01) Contact output signal 3 Select function 16. Press the [] key.
If the product is operated 24 hours per day, the product life will be as follows: Data memorized every 5 minutes --5 minutes x 1 million cycles = 5 million minutes = 9.5 years Data memorized every 2 minutes --2 minutes x 1 million cycles = 2 million minutes = 3.8 years
Panel mount adapter ZS-26-B With set screw M3 x 8L (2 pcs.) and waterproof seal Panel mount adapter + Front protective cover ZS-26-C With set screw M3 x 8L (2 pcs.) and waterproof seal Front protective cover ZS-26-01 48 conversion adapter ZS-26-D It is an adapter for attaching PSE200A series in the panel cut size of PSE100 series. -8No.PS-OMW0005-C Summary of Product parts Names of individual
Orange mark X 2. Removing the handle To remove the handle, align the mark on the handle and the mark on the bonnet and then pull the handle. Table 1. Clearance Dimensions Orange mark ARG30 AWG30 ARG40 AWG40 ARG20 AWG20 mark mark X dimension (reference value) Bonnet 3.3 mm 3.3 mm 2.6 mm 3.
Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 1 3 5 VX31 -00n x 100 + 50 Solenoid Specifications VX325-00n x 160 + 60 Temperature rise (C ) (Rated voltage) Power consumption (W) (Holding) Apparent power (VA) Frequency Power source Model VX335-00n x 160 + 60 (Hz) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area
Dimensions 2 x 5 machined for bar ring Mounting hole 4 x M3 x 0.5 5 1010 55 55 1.2 Alphabetical Index Length Measuring/ Counter 6 (3.7) 67.4 59 55 65 CH IN OUT (3) 33.5 139 8 40 158 41.2 (2) 55 55 2 x 8 6 x 4 16 14 16 16 14 16 14 10 25 25 597 Series PCW 16 Point Output Reduced Common Unit Specifications Model Output PCW-993195 Weight 80 g Refer to page 43 in CAT.E02-20 about the circuit
10-2 l/min, CFM x 10-1 Real-time flow rate Accumulated flow Display units Note 1, 2) l, ft3 x 10-1 Operating fluid temperature Linearity Repeatability Temperature characteristics Current consumption (No load) Weight Note 3) Port size (Rc, NPT, G) Detection type Indicator light Operating pressure range Proof pressure Accumulated flow range Note 4) 0 to 50C 5% F.S. or less 1% F.S. or less 2%
0.7 Female mounting threads Thread depth 6 Silencer (AN120-M5) Option (PB1011 built-in solenoid valve type only) AIR SUP (pilot air supply port) Rc 1/8 FLUID IN Rc 1/8 9 11 22 13 SUP IN 11 18.5 32 EXH Foot bracket Option 45 AIR EXH (pilot air exhaust port) 2-M4 x 0.7 Female mounting threads Thread depth 6 M5 x 0.8 Thread depth 10 The PB1013 air operated type has a plug. 20 Related Products
IP address setting The IP address is set either using the manual setting of the IP address X/Y switch, or by remote control (with the IP address X switch set to "000"). When setting the IP address by remote control, first obtain the IP address through the BOOTP/DHCP Server, then select the Disable DHCP button to hold the IP address. 2.
If the product is operated 24 hours per day, the maximum writable limit will be as follows: Data memorized every 5 minutes --5 minutes x 1 million cycles = 5 million minutes = 9.5 years Data memorized every 2 minutes --2 minutes x 1 million cycles = 2 million minutes = 3.8 years
M3 x 30 screw for connection to the valve manifold.
Description Material 1 5 SCS13 Cover O-ring 2 6 SCS13 Bowl Seal NBR 7 O-ring 65 x 250mm 3 SUS304 Element FPM 8 Scraper 65 x 500mm FN111 FN112 9 O-ring CDLQB63-30D-F Compact cylinder with lock 4 CDLQB63-50D-F Replacement parts: Seal kit Note Model Order no. Material FN11N NBR KT-FN11N Items 5 through 9 from the above chart.