Body Size: 30, Thread: Rc, Port Size: 03 (3/8), Option: BC (B + C), Semi-Standard 1: R (Flow Direction Right to Left), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 40, Thread: Rc, Port Size: 03 (3/8), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 6R (6 + R), Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard, Made to Order: X2141 (w/Element Service Indicator)
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: Standard, Semi-Standard 2: Standard, Made to Order: X2141 (w/Element Service Indicator)
Body Size: 30, Thread: Rc, Port Size: 03 (3/8), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: Standard, Semi-Standard 2: Standard, Made to Order: X2141 (w/Element Service Indicator)
Body Size: 40, Thread: N (NPT), Port Size: 03 (3/8), Option: Standard, Semi-Standard 1: J (Drain Guide: 1/8 for Body Size 20; 1/4 for Body Size 30 & 40), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 30, Thread: Rc, Port Size: 03 (3/8), Option: BD (B + D), Semi-Standard 1: R (Flow Direction Right to Left), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: Standard, Semi-Standard 1: 6R (6 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: F (G), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: Flow Adj.
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.:
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link