(Normally open) 1 2 Note) B Option Note) Latching manual override: push-locking type only.
Possible to use as a 2-port valve by plugging the 3(B) port.
Note) O-rings cannot be shipped as a single unit. 4 1 PVQ 8 3 3 A B 2 1 Body ported Base mounted 2 1 VY1 4 3 5 VBA VBAT 1 1 2 1 1 4 1 7 1 4 1 AP100 1 2 9 2 Without sub-plate 8 1 2 4 1 Option (2) Part no.
0.8 22.5 2.5 Finger opening port 4.5 11.5 23 11 2 18 25 15.5 41.5 5 33 Angle adjustment bolt 63 11 2 x 4.5 through 2 depth 4 +0.025 0 3 x 3H9 (one each on three sides) 2 x 8 depth of counter bore 2.5 10 long groove depth 3 +0.025 0 3 x 3H9 (one each on three sides) 0 -0.062 37h9 M5 x 0.8 M5 x 0.8 Port A Port B 4 x M4 x 0.7 depth 6 N J I E A D P A A M N 2 C M S R R E O P T 6 P A R I R Y G
Note 2) The figure shows an extended piston rod. 10-9-10 10 Heavy Duty Stopper Cylinder Series RSH/RS1H Proper Auto Switch Mounting Position Auto switch B A RE A B REC CX CY Proper Auto Switch Mounting Position D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W Auto switch models MQQ M D-Y69 D-Y7PV D-Y7WV D-Y7BAL RHC Bore size (mm) A B A B A B MK(2) 20 8(6.5) 18 18 9.5 18 2 32 10.5(9) 13.5 13.5 12 13.5 4.5 RS
(650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RHC Bore size (mm) A B A B A B MK(2) 20 8(6.5) 18 18 9.5 18 2 32 10.5(9) 13.5 13.5 12 13.5 4.5 RS Q G 50 12(10.5) 22 22 13.5 22 6 63 15.5(14) 24.5 24.5 17 24.5 9.5 RS H A 80 22(20.5) 37 37 23.5 37 16 The values inside ( ) are for D-Z73.
B (9.5) B (12.7) B (19.1) B (25.4) B (31.8) B (38.1) B (50.8) VNA 111 211 311 411 511 611 711 AS 420-03 420-04 500-06 600-10 800-12 900-14 900-20 3 8 1 2 3 4 10A 15A 20A 25A 32A 40A 50A 1 2 VNA01 VNA02 VNA03 VNA1 Port 12 (P1) 1 1 1 2 External pilot External pilot External pilot External pilot External pilot Pilot exhaust Bleed port Bleed port 1 4 1 2 10 (P2) Installing a silencer to the
) Main port 1(A) (Back side 2(B)) Port size: refer to table below 65 (Grommet terminal: E) 70 (Conduit terminal: T) 74.5 (DIN terminal: D) Bracket 2 x M4 x 0.7 depth 7 2 x 4.5 Main port 1(A), 2(B) Model VNA1-6A VNA1-8A VNA1-10A 1 8 1 4 3 8 In the case of EZ or TZ, the length is longer by 10 mm.
ZPX40HBN-B01-B8 -B10 ZPX50HBN-B01-B8 -B10 ZPX63HBN-B01-B10 -B12 ZPX 80HBN-B01-B10 -B12 ZPX100HBN-B01-B10 -B12 ZPX125HBN-B01-B10 -B12 150 275 40 50 63 80 100 125 +1 0 +10 152 271 1 +1 0 +19 166 464 2 +2 0 +37 164 460 3 +2 0 +61 235 648 6 +4 +1 +121 225 644 12 +7 +3 +228 22 How to Order ZPX 40 HB N B01 B10 Pad diameter (mm) Mounting thread 40, 50 63, 80 100, , 125 40 40 50 B 8 50 M8 x 1.25
L1 M2 = m g (L1 + B) 103 2. Static moment m x g = 1 9.8 (50 + 48) 103 Review M2. Since M1 & M3 are not generated, review is unnecessary. = 0.96 [Nm] 2 = M2/M2 max = 0.96/4 = 0.24 M Guide shaft mounting surface L1 B We = 5 x 103 m g U = 5 x 103 1 9.8 300 = 14.7 [N] Me3 = 1/3 We (L2 + A) 103 3.
. 2-2 Names of each part Table 2-1 Accessory list 2pcs. 1 Alarm cord list label (English 1pc.
(Refer to Figure 1 or Figure 2.) 2) A meter-out-type speed controller is used for ports A and B and a meter-in speed controller is used for ports C and D. (Figures 1 and 2 show the state at which pressure is applied to ports B and D.) 3-position pressure center solenoid valve: 1 pc. Figure 1 3-position solenoid valve: 2 pcs.
4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: (1 : ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
AW-OMZ0062 PRODUCT NAME icro Mist Separator Regulator MODEL / Series / Product Number AWD20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWD30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWD40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3.
AW-OMZ0061 PRODUCT NAME Mist Separator Regulator MODEL / Series / Product Number AWM20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWM30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWM40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3. Standard Specifications 9 4.
OUT2 17 OUT output bit Accumulated 1 32 Accumulated 2 33 Flow rate 1 34 Flow rate 2 35 Connected with hardware output SW output bit (Not connected as OUT2 does not have the hardware) Temperature 1 36 Temperature 2 37 Pressure 1 38 Pressure 2 39 Pulse output 2 65 This is valid only when the output object of OUT2 is pulse output.
4 0.1 [MPa] 2 1 2 0 0 0 0 3 2.5 2 1.5 1 0.5 Distance from the workpiece [mm] 0 3 2.5 2 1.5 1 0.5 Distance from the workpiece [mm] 0 1 1.5 0.5 2 2.5 3 Distance from the workpiece [mm] ZNC60m ZNC80m 30 70 0.5 [MPa] 0.5 [MPa] 60 25 0.4 [MPa] 0.4 [MPa] 50 Lifting force [N] Lifting force [N] 20 0.3 [MPa] 0.3 [MPa] 40 15 0.2 [MPa] 0.2 [MPa] 30 0.1 [MPa] 0.1 [MPa] 10 20 5 10 0 0 0 3 2.5 2 1.5 1
2-Color Display Solid State Auto Switch D-M9BW(V), D-M9NW(V), D-M9PW MXY (mm) B A Model Mounting Auto switch operating range MTS A B A B A B 50 3 MXY6 38 55 MXY8 3.5 43 63 MXY12 3 51 Adjust the auto switch after confirming the operating conditions in the actual setting.
L1 M2 = m g (L1 + B) 103 2. Static moment m x g = 1 9.8 (50 + 48) 103 Review M2. Since M1 & M3 are not generated, review is unnecessary. = 0.96 [Nm] 2 = M2/M2 max = 0.96/4 = 0.24 M Guide shaft mounting surface L1 B We = 5 x 103 m g U = 5 x 103 1 9.8 300 = 14.7 [N] Me3 = 1/3 We (L2 + A) 103 3.
B Through hole/ Double end tap common (standard) Number of auto switches Bore size 12 16 20 25 2 pcs. 1 pc.