SMC Corporation of America
Elite Part Number Search
Search Results "VXA3224-03N"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, STEAM, VALVE, VX2 2-WAY MEDIA VALVE, EA, VX2 BODY PT 1/4 NPT, 1.22933 lb

Direct air operated, 2 and 3 port valve series VXA can be used with a wide variety of fluids. The manifold for the VXA21/22 series is available in a common SUP style or individual SUP style (for vacuum use). The VXA31/32 series manifold is individual ported. Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style

SMC has developed the VXE series energy saving type, 2 port solenoid valve?to help with environmental issues.? The PWM (Pulse Width Modulation) method was used to allow for less power consumption.? By reducing the energy consumption we have also reduced the heat produced by the coil. This series is available in three styles VXE directed operated, VXED pilot operated, and VXEZ?zero differential

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX2 2-WAY MEDIA VALVE, 2A, VX2, 1.81789 lb, Port sizeOrifice size (mm?)ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) C[dm3/(s?bar)]bCv3/8 (10A)8VXK2350-030.24.90.291.201.0790

Direct air operated, 2 and 3 port valve series VXA can be used with a wide variety of fluids. The manifold for the VXA21/22 series is available in a common SUP style or individual SUP style (for vacuum use). The VXA31/32 series manifold is individual ported. Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style

Direct air operated, 2 and 3 port valve series VXA can be used with a wide variety of fluids. The manifold for the VXA21/22 series is available in a common SUP style or individual SUP style (for vacuum use). The VXA31/32 series manifold is individual ported. Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, GA, VX3 BODY PT 3/8NPT, 1.31722 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX32?------1/43/8

The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure

The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, GC, VX3 BODY PT 3/8NPT, 1.88967 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX33?------1/43/8

The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, GA, VX3 BODY PT 3/8NPT, 1.76369 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX33?------1/43/8

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, GB, VX3 BODY PT 3/8NPT, .00000 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?4 mm?VX33?------1/43/8

The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure

The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding

The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding

The SV series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations are greatly simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also available

Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa

The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure