SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B100-15+0DCM-XC11"

MY50-16A-Stroke 14 Seal belt 1 MY50-16B-Stroke MY63-16B-Stroke MY80-16B-Stroke MY100-16B-Stroke Dust seal band 15 1 MYB50-15CA7165B MYB63-15CA7166B MYB80-15CK2470B MY100-15CK2471B Side scraper 27 2 14, 15, 27 and 34 are not included in the seal kit. Order them as required with by individual part numbers.

(Series MA3 only) (Series MA3 only) Rotary actuated type MHR2-10 15 Refer to AHC system Series MA. 12-12-17

Pressure Control Equipment Industrial Filters For 13 hole (Round/Without Shim) For 20 hole (Diamond/Without Shim) CKQG-R128 CKQG-D198 CKQG-D199 CKQG-R129 CKQG-R130 CKQG-D200 CKQG-D195S CKQG-R125S CKQG-D197S CKQG-R127S For 13 hole (Round/With Shim) For 20 hole (Diamond/With Shim) CKQG-R128S CKQG-D198S CKQG-D199S CKQG-R129S CKQG-D200S CKQG-R130S CKQG-R145 CKQG-R245 CKQG-R147 CKQG-R247 For 15

Sine Rodless Cylinder/Linear Guide Type Series REBH Single axis type: 15, 25 Construction Single axis type: 15, 25 #1 #2 #0 @9 #5 #4 #3 REBH15 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series REBH. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no.

Connection thread Recommended proper torque [Nm] M5 1.5 to 2 1/4 8 to 12 3/8 15 to 20 2. Do not allow twisting or bending moment to be applied other than the weight of the equipment. Provide separate support for external piping, as damage may otherwise occur. 3.

P D KG M KFG2 A L 8 4.2 MS D KKA H Connection threads KP KP Straight Union: KPQH, KPGH LQ Effective area mm2 D Model L Applicable tubing O.D. mm Note 1) 2 x Applicable tubing Weight g M MQR TPH TPS 4 KPQH04-00 KPGH04-00 10.4 35.4 17 4 4 4 D D T 6 KPQH06-00 KPGH06-00 12.8 18.5 10 10 6 37.6 M M L 8 KPQH08-00 KPGH08-00 15.2 26 18 10 42.4 20.5 IDK 10 KPQH10-00 KPGH10-00 18.5 29 15 46.6 23 41

Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications 6 10 Bore size (mm) Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Piston speed Cushion Stroke adjustable range Port size Air (Non-lube) Size Suction flow rate L/min (ANR) 6 10 1.05 MPa 7 15 0.7 MPa 0.15 MPa 0.1 MPa 10C to 60C (No freezing) 30 to 400 mm/s Rubber bumper

pressure 0.3 MPa 5.0 Inlet pressure 0.3 MPa 3.0 Pressure drop [kPa] Pressure drop [kPa] Pressure drop [kPa] 2.5 4.0 2.5 Inlet pressure 0.5 MPa Inlet pressure 0.5 MPa 2.0 Inlet pressure 0.5 MPa 2.0 3.0 1.5 1.5 2.0 1.0 1.0 1.0 0.5 0.5 Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa 0.0 Inlet pressure 0.7 MPa 0.0 0.0 0 5 6 7 8 1 2 3 4 2 1 3 4 5 6 7 8 9 10 11 12 0 2 4 6 8 1 3 5 7 9 10 12 14 11 13 15

VA, DC: 15 W Contact point construction: 1a, 1b Maintenance space Float switch Part no.

AMV 15 20 Creates a comfortable work-ing environment without greasy fumes. Port size Exhaust cleaner for vacuum pump 10 14 20 30 40 R1 R1 R2 80 (3B) JIS 10K FF flange 1 2 Captures and separates 99.5% of even low-flow and highly concentrated greasy fumes. Using the AMV series, greasy fumes cannot be visibly recognized in the exhaust from the vacuum pump.

1 VBA VBAT 7 9 AP100 Material Note Component Parts 14 4 Description Body Valve guide Bonnet Piston Valve Adjusting screw Panel nut Hexagon nut Adjusting spring Valve spring Spring holder Mini Y-seal O-ring Lock washer Bracket Pressure gauge Cassette No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Aluminum alloy Brass Brass POM Brass Iron Iron Iron Steel wire Stainless steel Steel band NBR

Flash Operating voltage 24 VDC +20%/-15%, Class 2 1 ON US2 [US3, US4 .. etc] is present (> approx. 22.8 VDC). Detected: < approx. 20.4 VDC Cancelled: > approx. 21.6 VDC 3 : If the US2 power supply is not present or below the dropout level, the SF LED will also flash and the error code "0x01F1" will be generated.

I/O monitor(I/O ) 15 2. Diagnosis Data() 24 3. Sys. Configuration() 27 4. Parameter Setting() 33 5.

Doc.No.LFE*-OMZ0012 Product Name Electromagnetic Digital Flow Switch Remote Type Model/ Series/ Product Number LFE#(Z) SMC Corporation Contents Safety Instructions 2 Model Indication and How to Order 11 Summary of Product Parts 13 Definition and Terminology 14 Mounting and Installation 15 Installation 17 Piping Method 18 Wiring 20 Maintenance and Inspection 22 Troubleshooting 23 Specifications

The maximum operating 0 5 10 15 20 25 30 ( temperature for the valve is 150oC. If the heater temperature is over 200oC or valve temperature is Time (sec.) Duration of the inrush current flow (as a guide) over 150oC, please use thermostat to control the heaters to prevent overheating.

40 800/50 XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 1 1 1 H5 AC100V 200/40 400/70 400/80 / AC200V 800/40 1600/80 1600/80 XLA-63-2 XLA-80-2 AC90240V XL1A25-60S-2 XL1A25-60S-3 1 1 H4 AC100V 400/100 600/150 / AC200V 1600/100 2400/150 XL1A25-60S-3 XL1A25-60S-2 1 2 H5 AC100V 600/130 800/180 / AC200V 2400/130 3200/180 1[W] 216 PTC 200V PTC 200 150 100V PTC 0 5 10 15

(9)(11)(12)(13) (14)(15)(16)(17) FGD-CA003 FGDT,F(L500) L500 (18) FGD-CA004 FGDC,E(L250) FGD-CA005 FGDC,E(L500) 7/11 FGX-OM-L007-C 2. 2.

(1) (2) (3) (4) (5) (6) OUT1 (1)OUT1OUT2 (2)+(3) (4)/ () (5)IP8000(2) (6)IP8100(3) 15 7-1 5 O K O O K K (1) 0% (4mAD (1) 0% (4mAD C) C) (2) 100%(20 (2) 100%(2 mADC) 0mADC) (3) 0%(1) (3) 0%(1) (4) (4) 16 7-2 / () mADC 17 18 18OUT1OUT2A 1718 ( 1/16-1 ) 11-1(/) 7-3 A 1M1/8OUT117 1/8 1/81/4 2A(17) SUPOUT1 A 17 8.

For detailed description of the signals, refer to the following pages. 15 (2) Internal circuit (Numbers in brackets indicates the pin numbers) (5) PWR_DC24V LF (6) PWR_GND Output signal GND (9) CTR (10) CYL (11) VAL (16) RF (17) PWR Max.

No.PS-OMS0004CN-D // PSE570/573/574 2 8 9 10 10 14 15 15 17 -1No.PS-OMS0004CN-D (ISO/IEC)(JIS) 1) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety