Series: KQ2, Model: ZT (Universal Triple Branch Male Elbow), Applicable Tubing O.D.: Ø10, Port Size/Applicable Tubing O.D.: 02 (Screw Connection R1/4, Rc1/4), Thread Material/Surface Treatment: N (Brass + Electroless Nickel Plated)
Size: 3 (Body Ported), Operation: 0 (Air Operated Style), Sealant: Nitrile Rubber, Port Size: 02 (1/4), Thread: N (NPT)
The SV series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations are greatly simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also available
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Series AF modular style air filter is a cost effective, clean looking solution to your filtration needs. Its' modular design allows connection with other SMC air preparation equipment. The series is available in six size options with a wide range of accessories.Modular air filter , Prevents contamination , Lighter weight than old style modular AF , Thickness reduction of resin case provides
Series AMC exhaust cleaners insure clean plant air and reduce noise pollution over 35dB. The AMC series also removes over 99.9% of oil mist. Choose from R(PT), NPT or G(PF) thread styles.Fluid: compressed air, Effective area mm 2 (Cv): male thread style 16 (0.88) - 550 (31); female thread style 12 (0.66) - 55 (3.1), Noise reduction: 35db or more, Oil mist removal: 99.9% or more, Element
SMCs VQ7-6/7-8 series valve conforms to ISO standard 5591/I. A choice of metal or rubber seal increases compatibility with various operating and environmental conditions. Manifolds are available with a wide range of interface options to meet a variety of application requirements. The VQ7-6/7-8 has a smaller, space-saving profile and is lighter in weight than the VS7/VP7 series. Manifold
The SV series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations are greatly simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also available
Solenoid: 1 (Single Solenoid), Voltage: B (24 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: None, Manual Override/Classification: B (Locking Slotted Style-Tool Required), Thread: N (NPT)
Solenoid: 2 (Double Solenoid), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: None, Manual Override/Classification: A (Non-locking Push Extended Style), Thread: N (NPT)
Model: 32, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: DO (DIN Terminal, w/o Connector, Gasket Included), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4), Thread: N (NPT)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: U (With light/surge voltage suppressor (Non-polar type)), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: N (NPT)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: N (NPT)
Series: 3 (VQZ3000), Configuration: 1 (2 Position Single), Seal Type: 0 (Metal Seal), Function: R (External Pilot), Coil Voltage: 3 [110VAC (115VAC) 50/60HZ], Lead Wire: YZ (DIN Terminal w/Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 02 (Rc1/4), Thread: N (NPT)
Model: LVH30 (Body Class 3, N.C.), Lever Operation: Non-locking, Self-reset, Port Size: 02 (1/4), Pilot Port Thread: N (NPT), Material: A (Body: SUS, Actuator Section: PP, Diaphragm: PTFE)