Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, RG, VFS5000 BASE MT 1/2, 4.66645 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, SG, VFS5000 BASE MT 3/4, 4.88008 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE, DBL SOL, PLUG-IN, VALVE, VFS5000 SOL VALVE 4/5 PORT, SI, VFS5000 BASE MT 3/4, 5.25152 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2I, VFS5000, 1.606 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, RI, VFS5000 BASE MT 1/2, 4.29901 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, SI, VFS5000 BASE MT 3/4, 5.07063 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2I, VFS5000, 2.85344 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, RI, VFS5000 BASE MT 1/2, 4.32445 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, SI, VFS5000 BASE MT 3/4, 6.44483 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, RI, VFS5000 BASE MT 1/2, 5.71312 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60C, VALVE SGL NON-PLUG-IN BASE MT, VALVE, VFS6000 SOL VALVE 4/5 PORT, SD, VFS6000 BASE MT 3/4, 7.64269 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, 100 VAC, VALVE, VT3/VO3 SOL VALVE 3-PORT, QA, VT3 BASE MT 3/8, 1.32636 lb

Ball joint, heavy duty bellows type pad with buffer, Vertical vacuum inlet direction, Pad diameter: 40, 50, 63, 80, 100, 125, Buffer stroke: 25, 50, 75, 100, H/D BALL JOINT W/BUFFR VAC PAD, VACUUM SERIES, OTHER OTHER MISC., 1M, OTHER OTHER SIZE RATING, 1.04720 lb

Ball joint, heavy duty bellows type pad with buffer, Vertical vacuum inlet direction, Pad diameter: 40, 50, 63, 80, 100, 125, Buffer stroke: 25, 50, 75, 100, H/D BALL JOINT W/BUFFR VAC PAD, VACUUM SERIES, OTHER OTHER MISC., 1M, OTHER OTHER SIZE RATING, 1.43302 lb

Please contact us for the latest version.sales@ocaire.com, H/D BALL JOINT W/BUFFR VAC PAD, VACUUM SERIES, OTHER OTHER MISC., 1M, OTHER OTHER SIZE RATING, 1.54323 lb

Please contact us for the latest version.sales@ocaire.com, H/D BALL JOINT W/BUFFR VAC PAD, VACUUM SERIES, OTHER OTHER MISC., 1M, OTHER OTHER SIZE RATING, 1.37788 lb

3C)Lights when ON, OUT1: Green, OUT2: RedIP40Operating/Stored: 35 to 85% RH (with no condensation)1000 VAC for 1 min. between live parts and case50 M or more (at 500 VDC) between live parts and case10 to 150 Hz at the smaller of amplitude 1.5 mm or acceleration 20 m/s2 in X, Y, Z directions for 2 hrs. each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.

3C)Lights when ON, OUT1: Green, OUT2: RedIP40Operating/Stored: 35 to 85% RH (with no condensation)1000 VAC for 1 min. between live parts and case50 M or more (at 500 VDC) between live parts and case10 to 150 Hz at the smaller of amplitude 1.5 mm or acceleration 20 m/s2 in X, Y, Z directions for 2 hrs. each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized