PF3A7*H digital flow sensors with modular connection provides simple integration with SMC's AC30 and AC40 air preparation units.  The flow sensor provides instantaneous flow data as well as cumulative air consumption values.  These units are available with digital and analog outputs.

Rated flow range: PF3A701H: 10 TO 1000 lpm; PF3A702H: 20 to 2000 lpm; Large 2 screen, 3 color display to show both instantaneous and cumulative flow or set value at the same time; Can be converted to threaded model using modular connectors and piping adapters ; Accuracy: +/-3.0% F.S.

PF3A7*H digital flow sensors with modular connection provides simple integration with SMC's AC30 and AC40 air preparation units.  The flow sensor provides instantaneous flow data as well as cumulative air consumption values.  These units are available with digital and analog outputs.

Rated flow range: PF3A701H: 10 TO 1000 lpm; PF3A702H: 20 to 2000 lpm; Large 2 screen, 3 color display to show both instantaneous and cumulative flow or set value at the same time; Can be converted to threaded model using modular connectors and piping adapters ; Accuracy: +/-3.0% F.S.

Body sizes: 16, 25, 32, 40; Stroke range: 50 to 1200mmin 50mm increments; Maximum work load: 75 kg (horizontal); 25 kg (vertical); Maximum speed: 1500 mm/s (H lead, size 25); Maximum acceleration: 10, 000 mm/s² (horizonal); 5,000mm/s² (vertical); Positioning repeatability: ±0.02mm (±0.015mm high precision type); Motor type: 24 VDC step motor with battery-less absolute encoder

A new high performance step motor controller, the JXC*H, pairs with the LEY*F actuator.  The machine's PLC can access the controller's operational and positional step data through several fieldbus protocols, IO-Link, or parallel I/O.  Actuator dimensions and mounting are identical to the standard LEY, allowing an upgrade for existing equipment. 

Motor operation is provided by the JXC*H High Performance controller line, with PLC, IO-Link or Ethernet fieldbus protocol interfaces.  Actuator dimensions and mounting are identical to the standard LEY, alowing an upgrade for existing equipment.  I/O and actuator cables are also identical to the standard LEY.

Motor operation is provided by the JXC*H High Performance controller line, with PLC, IO-Link or Ethernet fieldbus protocol interfaces.  Actuator dimensions and mounting are identical to the standard LEY, alowing an upgrade for existing equipment.  I/O and actuator cables are also identical to the standard LEY.

Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder

Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder

The ASB-H all-metal construction provides superior environmental resistance, making it ideal for use in environments with welding spatter.  The indicator allows the user to easily adjust the flow rate before mounting and operating the cylinder, which helps to reduce setting time and errors. 

Bore sizes: 20, 25, 32, 40, 50, 63, 80, 100 mm; Available in basic or front flange mounting; Adjustable stroke range: 10 mm (20 mm bore); Adjustable stroke range: 15 mm (25 - 100 mm bore); External shock absorbers as standard; Auto switch capable

Size: 32, Motor Mounting Position: R (Right Side Parallel), Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: A (Size 16: 10; Size 25: 12; Size 32: 16), Stroke: 50mm, Motor Option: B (with Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: D (Double Clevis), Controller Position: B (Integrated Controller), Parallel Input: 6 (PNP)

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/

Body/Exhaust Type: F (For Manifold - Individual Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: J (N.C. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum

Nominal Nozzle Size: 10 (ø1.0), Vacuum Port, Supply Port: C6U (Metric; Vacuum Port: ø6; Supply Port: ø6), Exhaust: H (High-noise Reduction Silencer Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor

Nominal Nozzle Size: 10 (ø1.0), Vacuum Port, Supply Port: C6 (Metric; Vacuum Port: ø6; Supply Port: Plug), Exhaust: H (High-noise Reduction Silencer Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor

Size: 16, Motor Mounting Position: Top Side Parallel, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: A (Size 16: 10; Size 25: 12; Size 32: 16), Stroke: 100mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Controller Position: B (Integrated Controller), Parallel Input: 6 (PNP)