For 200 VAC: SY100 30 2A For other voltages of AC: SY100 30 3A To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out.
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 Material Part no.
Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Electrical entry G C T TL Grommet Conduit Conduit terminal Conduit terminal with indicator light Clip part no. Note) Indicate the valve model no. as a label will be attached to the clip.
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
I direction \ j '--r:_ _ _ System diagram Supply by Lrser comFcrnecFic rouilo|'s $.0nie$ ll( Proilrd tooumr 30 :t0.03. 08; 2mm lead o5 stepping a a a a 80 08; 5mm lead 100 08; 6mm lead t0.05 200 @8; 12mm lead :a]8:?lrrin:Faq l: ':l ' :S? sleptrr.lS 19!1{11n]!
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Rc 1/2 Rc 11/2 Rc 2 3B flange Rc 11/4 Rc 1 32 67 78 Rc 1/2 Rc 1/2 Rc 3/4 Rc 3/4 Rc 1 Rc 3/4 Weight (kg) Coating color Drain valve (1 pc.) 9.7 11.5 59 95 High efficiency drain Drainage is efficiently removed by built-in drain separator. Visible outlet air temperature Outlet air temperature is easily checked by thermometer, resulting in easy maintenance.
For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500
Manifold base recommended dimensions Lead wire Base mounting hole 1 (IN) 2 (OUT) 1 (IN) 9.5 or more Valve mounting pitch 2 (OUT) A A M3 x 0.5 Thread depth 5 2 (OUT) port 1 (IN) port 3 M3 x 0.5 Thread depth 5 Electrical entry can be on the either side, right or left. 2 (OUT) port 3 11 11 40 Sectional view A-A (2:1) 4 4 46 or more RZ12.5 1 (IN) port 510 High Speed 2 Port Valve SX10 Series Control
Switch fastening position Light illuminating position 0.3 to 0.5mm Switch fastening position 2.10-11 Corporation of America The worlds leader in pneumatics A New Solution for High Temperature Applications with SMCs Series CQ2...
JIS Symbol How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body JIS Symbol Body size Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.
Content 0 10 1 11 2 12 3 13 4 14 5 15 6 16 7 17 Unit diagnostic status 1 7 6 5 4 3 2 1 0 Byte 3 Bit No.
JIS Symbol How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body JIS Symbol Body size Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 1.5
Count Pressure characteristics Flow characteristics Supply pressure: 0.2MPa Set pressure: 0.05MPa Relief flow characteristics Supply pressure: 0.2MPa 0.15 1.0 0.25 Output deviation factor (%F.S.) 0.20 0.5 Set pressure (MPa) Set pressure (MPa) 0.10 Set point 0.15 0.0 0.10 0.05 0.5 0.05 1.0 0 200 400 600 0.00 0.0 0.1 0.2 0.3 0 200 400 800 600 Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
equivalent (130C) (6) 51 45 17 (5.3) 11 (2.9) 5.5 50 Hz 60 Hz 50 Hz 60 Hz Inrush Apparent power (VA) (Power consumption (W)) VP AC Holding S070 Power consumption (W) DC Bracket (AXT338-11)/For body ported type VQ Accessory (Option) Indicator light Body ported Manual override VKF Note 1) Based on JIS B 8375-1981.
Series CBQ2 Allowable Kinetic Energy Allowable Rod End Lateral Load 0.5MPa 0.4MPa With rubber bumper With auto switch (lateral resistance) 200 100 100 50 50 40 30 Allowable lateral load W (N) 63 20 Load weight kg 50 10 63 40 32 10 5 4 3 50 5 2 40 1 0 10 20 30 40 50 60 70 80 90 100 32 Stroke St (mm) 1 50 100 200 500 300 Maximum speed mm/s (Mounting orientation: Horizontal) W
Refer to LECYU Operation Manual,section 3.3.1. and 3.3.2. 11 - 2.3.1 I/O Signal (CN1) Names and Functions The following table shows the names and functions of I/O signals (CN1). (1) Input Signals Signal Pin No.
. %% 11 11 0/ 1 1 01 Model # % " . " " " 0 %% VVX311-stations VVX312-stations VVX321-stations VVX322-stations VVX331-stations VVX332-stations / 0 Manifold / 0 / 0 0 0 % ( 1 17-3-87 2 The models VX31/32/33 have been revised. For details, please refer to catalog no. ES70-26A. Similar updating for other VX series are scheduled to follow shortly.