Please contact us for the latest version.sales@ocaire.com, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, HE, 20MM MHZ2, .72571 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalDouble actingDouble actingMHZ2-20D(N)20426610235
Size, Body, Valve Type: 20D (Size: 2; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 4, N.C.), Voltage and Electrical Entry: A (24VDC; Grommet), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread), Bracket Interchangeable with Old Type: XB, Electrical Entry: C (270°)
Size, Body, Valve Type: 20D (Size: 2; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 4, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 1B (220VAC; Grommet w/Surge Voltage Suppressor), Other Options: A (G Thread)
Size, Body, Valve Type: 20D (Size: 2; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 4, N.C.), Voltage and Electrical Entry: C (110VAC; Grommet w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread), Bracket Interchangeable with Old Type: XB
Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 mm, Stroke: 20 mm, Rod End Thread: Without Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Option: -
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 mm, Stroke: 20 mm, Rod End Thread: B (Without Thread), Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 10 mm
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 5 mm
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 15 mm
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 25 mm
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 15 mm, Rod End Thread: With Thread, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, 0.5M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 15 mm, Rod End Thread: With Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)