M5 type U10/32 type Applicable tubing O.D. d (Hexagon width across flats) Metric Size Inch Size Model d T Weight (g) H D1 D2 L1 L2 L3 L4 (1) A (2) Model d T Weight (g) H D1 D2 L1 L2 L3 L4 (1) A (2) Max.
DHCP TCP/IPIP DIN DIN() DLR DLR(devicelevelring D EX600 EX600 EDS ( FE Functional Earth H.T.
Printed in Japan. 1st printing June, 1999 D-SMC.L.A. P-100 (YG) 4th printing April, 2002 D-DN P-80 (DN)
[mm] Ionizer front back direction [mm] 150 100 50 0 50 100 150 150 100 50 0 50 100 150 250 200 150 100 50 0 50 100 150 200 250 0 0 50 50 100 100 1 s 0.5 s 150 150 0.5 s 200 200 2 s 1 s 2 s 250 250 5 s 5 s 300 300 3) With energy saving type de-ionizing cartridge, Supply pressure: 0.3 MPa Installation distance in height from ionizer to workpiece (Charged object location) [mm] Installation
BF SOL RUN Display Description NOTE When connecting manifold valve only without connecting Input unit manifold, LEDs of COM A D do not light. To make them light, connect a terminal plug to the unused connector of SI unit ( "C1" or "0" ). Settings for display Turns on: COM D is receiving data. Turns off: COM D has no received data. Turns on: COM C is receiving data.
Controller (VYU5-D) External appearance of exclusive controller RUN1 STOP START SEL. SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.
Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting + Semi-standard Nil R Flow direction d
Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting + Semi-standard Nil R Flow direction d
Applications) Direct Operated Precision Regulator with Backflow Function (For Special Applications) Series ARP20K to ARP40K 10 20 2110 20 21-ARP20/ARP20K 10 20 21 -ARP30/ARP30K 10 20 21 -ARP40/ARP40K 10 20 21 Description Symbol Body size 20 30 40 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting + Semi-standard Nil R Flow direction d
5 15-17-5 6 Series AS-FPQ/FPG Dimensions H (width across flats) Applicable tubing O.D. d A L4 D1 L3 D2 M1 L1 L2 T M5 type H (width across flats) Applicable tubing O.D. d A A4 D1 L3 D2 M1 L1 T L2 Model Weight (g) Note 2) Tubing O.D. d T H D1 D2 L1 L2 L3 M1 L4 Max. Min. Max. 1 2 Min.
e f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .
250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read the graph The sonic range pressure to generate a flow rate of 500 l/min (ANR) is P1 0.14 MPa for a 6 orifice (VX2 4), and P1 0.3 MPa for a 4.5 orifice (VX23). 3 2 For Saturated Steam [663] (179) Upstream
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification