Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: With auto switch mounting bracket, Auto
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 20mm, Stroke: 50mm, Rod End Thread: Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 20mm, Stroke: 50mm, Rod End Thread: Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 32mm, Stroke: 100mm, Rod End Thread: Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: Built-in, Mounting: Basic, Bore Size: 32mm, Stroke: 100mm, Rod End Thread: Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Magnet: D (Built-in), Mounting: U (Rod Trunnion), Bore Size: 20mm, Stroke: 50mm, Rod End Thread: Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 32mm, Stroke: 125mm, Rod End Thread: Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: UZ (Boss-cut/Rod Trunnion), Bore Size: 25mm, Stroke: 50mm, Rod End Thread: Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: With auto switch mounting bracket, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: With auto switch mounting bracket, Auto
Magnet: Built-in, Mounting: Front Flange, Bore Size: 32mm, Stroke: 125mm, Rod End Thread: Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: M9BW (with mounting bracket), Lead Wire
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: M9BW (with mounting bracket), Lead Wire
(One station of programmable driver remote device station) (c) Max. number of connected units: 42 Note that the following conditions must be satisfied. {(1 a) (2 b) (3 c) (4 d)} 64 a: Number of 1-station occupying units b: Number of 2-station occupying units c: Number of 3-station occupying units (not available for LECSC2-T) d: Number of 4-station occupying units (not available for LECSC2
11(11.5) 11.5 11.5 D-A7A8 D-F77979W 32 55 28 [deg] 40 46 27 32 10 4 [deg] 40 7 3 80100 24.5(25) 25 32 170190 32(32.5) 32.5 B [mm] 40 170190 41(41.5) 41.5 80190 31.5(32) 32 ( ) : D-A72A7HA80H 25 7. 7. 7. 7. 7.1 7.2 (7.1)A A ON A B A OFFB ON (7.2)A A ON A B A OFFB ON 26 8. 8. 8. 8. 8-1
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
For actuators with external stopper, the rotation end can be set within the ranges shown in the drawing by adjusting the stopper bolt. c l o r e c t k n w u o i s C e CRB2 CRBU2 CRB1 MSU B port A port C e l o s c i w k CRJ Basic type For 90 and 100 For 180 and 190 CRA1 Single flat Single flat CRQ2 MSQ MRQ D+10 0 B port A port B port A port +8 0 00 20t 1 0 t 9 fla la gle e f gl sin sin of
35) 10 (10) 16.5 19.2 18.4 21.6 20.5 23.2 22.4 25.6 05 20 10 A A 30 (25) 10 (10) 1 15 10 For D-F9, D-M9 Operating angle m: Value of the operating range Lm of a single auto switch converted to an axial rotating angle.
A,B),20(A,B),25(A)) (MXQ16(A,B),20(A,B),25(A)) 12 13 A 14 15 16 17 18 19 (MXQ6A,8A,12A, MXQ16(A,B),20(A,B),25(A)) 20 21 22 O 19 / 23 24 25 26 27 28 / 29 30 31 32 33 34 35 36 NBR 37 NBR 38 NBR 39 (MXQ6,8(C),12(C)) / 40 (MXQ6,MXQ8(C),MXQ12(C)) 41 NBR (MXQ6,MXQ8(C),MXQ12(C)) 42 (MXQ6,MXQ8(C),MXQ12(C)) 43 20 Revision history 4-14-1, Sotokanda,
(One station of programmable driver remote device station) (c) Max. number of connected units: 42 Note that the following conditions must be satisfied. {(1 a) (2 b) (3 c) (4 d)} 64 a: Number of 1-station occupying units b: Number of 2-station occupying units c: Number of 3-station occupying units (not available for LECSC-) d: Number of 4-station occupying units (not available for LECSC-)