SMC Corporation of America
Elite Part Number Search
Search Results "CDS2F160-300-M9NL"

Applicable for the hightemperature environments Increased air flow capacity IDFB60 IDFB70 IDFB90 IDFB80 50 10 New Current model IDFB Series 49 IDFB Series 9 48 IDFB75E IDFB55E 47 IDFB22E IDFB37E 8 46 Max. 113F (45C) Max. 104F (40C) Ambient temperature Dew point [C] Dew point [F] 45 7 44 43 6 42 41 5 Max. 149F (65C) Max. 122F (50C) 40 Inlet air temperature 39 4 38 3 37 0 200 100 400 500 300

Series 12-REA Sine rodless cylinder 25, 32, 40, 50, 63 How to Order Clean series 12 Special treatment on sliding part Bore size (mm) 12 REA 25 300 Cylinder stroke (mm) Type Port type Symbol Nil TN TF Rc NPT G Model Bore size (mm) Maximum manufacturable stroke (mm) Model Port size Standard stroke (mm) Lubrication Rc1/8 NPT1/8 G1/8 Rc1/4 NPT1/4 G1/4 12-REA25 12-REA32 25 32 40 200, 250, 300

Sensors (R) (P) 7.4 3 (13) M plug connector (M) L plug connector: 10-VQD1151-L-M5 M plug connector: 10-VQD1151-M-M5 5 5 5.5 2(B) 4(A) Direct manual override Lead wire length 300 mm 27 Indicator light 17.6 11.2 3 3(R) 9 0.3 3.8 10.9 3.5 5.5 9.1 2 x mounting hole 33.5 28.5 37 38 1(P) 1(P) 5.5 12 4-M5 x 0.8 13 L plug connector (L) (P, A, B, R port) 49 50.5 M plug connector (M) 598 4 Port Direct

400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) ARP Pressure Characteristics (Representative Values) IR-A IR Conditions: Inlet pressure 0.7 MPa Outlet pressure 0.2 MPa Flow rate Q = 20 L/min (ANR) 0.30 IRV Outlet pressure (MPa) 0.25 Set point VEX 0.20 SRH SRP 0.15 SRF 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8

20 40 60 80 100 0 50 100 150 Flow rate L/min (ANR) Flow rate L/min (ANR) Condition: Inlet pressure 0.7 MPa ARM11AA1-310-1 (One-touch fittings: IN 8, OUT 6) Condition: Inlet pressure 0.5 MPa ARM11AA1-310 (One-touch fittings: IN 8, OUT 6) 0.35 0.7 0.6 0.30 Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0.00 0 0 50 100 150 200 0 50 100 150 200 250 300

0 0 50 100 200 250 150 300 VBA VBAT Flow rate L/min (ANR) Flow rate L/min (ANR) AP100 Pressure Characteristics (Representative Value) Outlet pressure 0.2 MPa Flow rate 20 L/min (ANR) Condition: Inlet pressure 0.7 MPa Condition: Inlet pressure 0.5 MPa Outlet pressure 0.2 MPa Flow rate 20 L/min (ANR) ARM5BA-306 ARM5BA-306-1 0.30 0.30 Outlet pressure (MPa) Outlet pressure (MPa) 0.25 0.25 0.20

BUS IN side: No Link, No Activity Green ON BUS IN side: Link, No Activity L/A1 Green flashing BUS IN side: Link, Activity OFF BUS OUT side: No Link, No Activity Green ON BUS OUT side: Link, No Activity L/A2 Green flashing BUS OUT side: Link, Activity 21 EX## OMS1015-A Specification Specifications Model EX600-SPL1-X26 Enclosure IP67 (With manifold assembled) 1 Housing material PBT Weight 300

24 V 600 Max.28 V80 mA 1 V C15 V 1 k D420 mA 12 V 300 24 V 600 NPN PF3W7--GPNP PF3W7--HMax.28 V80 mA 1 V 30 ms Max.80 mA 1.5 V 30 ms -22No.PF-OMM0004-D NPN2 PF3W7--A(T)NPN PF3W7--C(T)PF3W7--D(T)NPN PF3W7--GPNP2 PF3W7--B(T)PNP PF3W7--E(T)PF3W7--F(T)PNP PF3W7--HOFF OUT2 OUT2 / -23No.PF-OMM0004-D 30() 3 ON OFF ON OFF [F 1]OUT1(60)[F 2]OUT2(36) -24No.PF-OMM0004-D 3 1 [P

24 V 600 Max.28 V80 mA 1 V C 15 V 1 k D420 mA 12 V 300 24 V 600 -18No.PF-OMN0011CN-C NPN PF3W30G PNP PF3W30H DC(+) DC(+) OUT1 OUT1 DC(-) DC(-) / / Max.80 mA 1.5 V 30 ms Max.28 V80 mA 1 V 30 ms 2 PF3W30J/PF3W30K DC(+) DC(-) / J15 V 1 k K420 mA 12 V 300 24 V 600 -19No.PF-OMN0011CN-C NPN2 PF3W30A NPN PF3W30C/PF3W30D NPN PF3W30G OUT1 OUT2(PF3W30A) DC(-) DC

Set range is 0 to 300 sec. to Contact input signal 2 OFF detection timer Setting and checking 43. Press the [SEL] key once. The set screen of contact input signal 2 OFF detection timer is displayed on the digital display. PV SV 44. Select contact input signal 2 OFF detection timer from the table below with [] key or [] key, and confirm by pressing SEL.

Set range is 0 to 300 sec. to Contact input signal 2 OFF detection timer Setting and checking 43. Press the [SEL] key once. The set screen of contact input signal 2 OFF detection timer is displayed on the digital display. PV SV 44. Select contact input signal 2 OFF detection timer from the table below with [] key or [] key, and confirm by pressing SEL.

Setting of the contact input signal 1 delay timer of reading Setting range: 0 to 300 seconds to Setting/Checking: Contact input signal 1 OFF detection timer 35. Press the [SEL] key once. Setting screen of contact input signal 1 OFF detection timer is displayed on the digital display. PV SV 36.

No.CE*-OMP0002-A 3 CEU1 SMC FG 0~50 35~85%RH 3 CEU1CE10.1mm 3 CE1-R** CE1** 3 CEU1** FG 3 DIN 3 2m/s 3 (100ms) 2 2 2 2-1 1 1 1 CEU1 4 2 2 2 2-2 2 2 2 3 3 3 3-1 1 1 1 : : 1 1 (mm) (mm) 25 25 25 25 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 125 150 150 150 150 175 175 175 175 200 200 200 200 250 250 250 250 300 300 300 300 400 400 400 400 500 500 500 500 12 12 12 12

*Refer to the table of Applicable stroke 6mm 6mm 8mm 8mm 10mm 10mm B B Cable type *Applicable stroke Standard produced upon receipt of order Without cable Nil Without cable Nil 100 100 200 200 300 300 400 400 500 500 600 600 700 700 800 800 900 900 1000 1000 Robotic type cable R Robotic type cable R 11-LEFS25 11-LEFS25 Standard cable S Standard cable S 11-LEFS32 11-LEFS32 Motor cable

MXH MXH Vertical Horizontal MXS L1: Load eccentricity MXQ m Mounting orientation m MXQ L H MXF L H MXW Maximum speed (mm/s) Up to 100 Up to 300 x Up to 500 Up to 100 100 b 50 v 200 n 50 m Up to 300 100 , 200 .

Delivery pressure (psig) 1.0 (25.4) 0.21 30 5 0.17 25 0.14 20 A Connections (mm) inch FV4 MV4 TW4 FV6 MV6 TW6 0.10 15 (70.6) 2.78 0.07 10 2.12 (53.8) 0.03 5 3.86 (98.0) 0.00 0 0 5 10 15 20 25 30 35 40 45 50 Flow rate (slpm, N2) 2.65 (67.3) SL5201A High flow option Inlet pressure: 2 psig (14 kPa) Standard 760 0 700 -8 Delivery pressure (Hg abs) 600 -21 Delivery pressure (kPa) 500 -35 400 -48 300

400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310-01 ARJF310F

Maintenance Caution Model Connection (Flange) 2B 8B C 2B/3B/4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 X l 400 Anchor bolt M20 X l 500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 q It is not possible to indicate a definite replacement interval for the element because it varies with the odor concentration of the compressed air.

100 300 500 300 500 700 1000 2000 2500 3000 4000 4000-06 5000 6000 1000 2000 3000 4000 4000-06 2550 3050 4050 4050-06 3050 4050 4050-06 2060 2560 3060 4060 4060-06 5060 6060 425 625 825 925 3000 210 1020 300 400 500 600 AWM Mist separator regulator VQZ AWD Micro mist separator regulator SQ AS Speed controller VQD SY Flow control valves SYJ SX 3-port solenoid valve (2) VQ VQ VQZ AS Speed

timer Grommet 3 wire(NPN) IC 5V, 12V G59F With diagnostic output (2 color) 4 wire(NPN) Latch with dianostic output (2 color) H7LF *Lead wire length 0.5m (Example) B80C 5m Z (Example) B80CZ 3m Z (Example) B80CL N (Example) B80CN * : Manufactured upon receipt of order Stroke Long stroke (mm) Standard stroke (mm) Model Bearing Bore size (mm) 20 25 32 40 50 75, 100, 125, 150, 200 250, 300