SMC Corporation of America
Elite Part Number Search
Search Results "CLA2B63-100-P"

Magnet: None, Mounting: Axial Foot, Stroke: 100mm, Port Location: 90° to Axis, Lock Style: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

V: Power supply voltage HRSH 090 HRSH 090 Power consumption P: 7 [kW] Q = P = 7 [kW] P HRSH Cooling capacity = Considering a safety factor of 20%, 7 [kW] x 1.2 = 8.4 [kW] Power consumption HRSE w Derive the heat generation amount from the power e Derive the heat generation amount from the output. HRZ supply output. Output (shaft power etc.)

100 80 80 Holding force (N) Holding force (N) Pressure 0.6MPa L Pressure 0.6MPa 60 60 0.5MPa 0.5MPa 0.4MPa 40 40 0.4MPa 0.3MPa 0.3MPa 20 20 0 0 20 40 60 80 100 20 40 60 80 100 Holding point L(mm) Holding point L(mm) 2.4-10 Series MHK2 Wedge Cam Operation Slide Guide Air Gripper (2 Finger) Effective Holding Force: Series MHKL2 Single acting Indication of effective holding force The holding

Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2.

Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur . 2.

Grease pack part no.: GR-S-010 (10 g) 80 Compact Cylinder/Water Resistant: Double Acting, Single Rod Series CQ2 Replacement Procedure is 20, 25, 32, 40 50, 63, 80, 100 P.290 Construction Standard (40 to 100) !2 !3 !1 !0 !3 !3 !2 !1 Without Auto Switch With Auto Switch The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205).

temperature: 113F (45C) RoHS How to Order IDF 30 100 FS Nil C K P R V Nil 1 2 3 Size Size Air compressor size Note) 100 100 kW 125 125 kW 150 150 kW Note) Note that the above values are for reference only.

0.15 mm 0.3 mm 0.03 mm 0.30 0.03 0.15 0.20 0.02 0.10 0.01 mm 0.10 0.01 0.05 0.05 mm 0.02 mm 0 0 0 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Piping length: 5 m Piping length: 5 m Piping length: 5 m Reference pressure 0.06 Reference pressure 0.30 Reference pressure 0.60 The distance of

V: Power supply voltage Power consumption P: 7 [kW] Q = P = 7 [kW] P Cooling capacity = Considering a safety factor of 20%, 7 [kW] x 1.2 = 8.4 [kW] Power consumption w Derive the heat generation amount from the power e Derive the heat generation amount from the output. supply output. Output (shaft power etc.)

Note 1) Consult P/A if other specifications for surface treatment are required.

= 0.5 MPa Bore size (mm) Effective cushion length (mm) Allowable kinetic energy (J) 70 50 100 50 100 40 20 R: 0.35, H: 0.42 R: 7, H: 7.5 25 R: 0.56, H: 0.65 R: 7, H: 7.5 100 32 Total load weight (kg) 32 0.91 7.5 100 25 40 1.8 8.7 10 50 3.4 11.8 100 20 High kinetic energy generated by large loads and high speed operations can be absorbed by compressing air at the stroke end thus preventing

Calculation Pad W P S t : Lifting force (N) : Vacuum pressure (kPa) : Pad area (cm 2) : Safety factor Horizontal lifting: 4 or more Vertical lifting: 8 or more Horizontal lifting Vertical lifting W = P x S x 0.1 x 1 t This type of application should basically be avoided.

Caution Check Safty Instructions on p.0-33 and common precautions on p.0-37 to 0-40. 4.0-14

Parenlneses CPA1 BN do Boot with Boot' BORE D E G'GB J K M MM N P H z.

S o.o t o.t 0.0 25 50 75 Inpul signal (%F.S.) o 25 50 75 100 InPUt signa ("/.F.S.)

Construction Symbol (B) 2 (A) 4 5 (R1) 1 (P) 3 (R2) Component Parts No.

Operating pressure P (MPa) P 0.7 MPa MTS 4.

100 kPa Operating pressure range and regulating pressure range Proof pressure 100 to 100 kPa 500 kPa 0.1 0.100 to 1.000 MPa 1.5 MPa kPa MPa kgf/cm2 s 0.001 0.01 0.01 0.1 0.001 0.001 0.02 1 0.1 Note 1) Setting/Display resolution ZSE ISE bar psi mmHg inHg PSE Z I SE3 Fluid that will not corrode stainless steel 630 and 304 12 to 24 VDC, Ripple (p-p) 10%or less 55 mA or less (With no load

V: Power supply voltage Power consumption P: 7 [kW] Q = P = 7 [kW] P Cooling capacity = Considering a safety factor of 20%, 7 [kW] x 1.2 = 8.4 [kW] Power consumption w Derive the heat generation amount from the power e Derive the heat generation amount from the output. supply output. Output (shaft power etc.)