: 80 Internal hold: 86 MHK2-16D 16 6 14.6 20.6 113 MHQ Double acting MHK2-20D 20 10 16 26 235 MHL2 MHK2-25D 25 14 19 33 440 MHK2-12S 120 76 13 9 4 12 9 MHR L1 Normally open Normally closed MHK2-16S 114 20.6 14.6 6 16 23 L2 MHK MHK2-20S 237 26 16 10 20 34 MHK2-25S 443 33 19 14 25 58 Single acting MHS MHK2-12C 76 13 9 4 12 12 MHK2-16C 115 20.6 14.6 6 16 25 MHK2-20C 237 26 16 10 20 44 MHK2-25C
20 10 16 26 8.3 O.D. holding:18.0 (80) I.D. holding :19.3 (86) MHK2-25D 25 14 19 33 15.5 MHK2-12S 120 12 2.0 (9) 4 9 13 2.7 Normally open Normally closed MHK2-16S 16 5.2 (23) 6 14.6 20.6 4.0 MHK2-20S 20 7.6 (34) 10 16 26 8.4 L1 MHK2-25S 25 13.0 (58) 14 19 33 15.6 Single acting L2 MHK2-12C 12 2.7 (12) 4 9 13 2.7 MHK2-16C 16 5.6 (25) 6 14.6 20.6 4.1 MHK2-20C 20 9.9 (44) 10 16 26 8.4 MHK2-25C
) Battery life Response speed 250 ms 2% F .S. or less (Temperatue conditions: at 25C) Display accuracy 1% F .S. or less (Temperatue conditions: at 25C) Repeatability 3% F .S. or less (0 to 50C with 25C standard) Temperature characteristics Piping port M5 x 0.8 0 to 50C (With no condensation) Ambient operating temperature Ambient operating humidity 35 to 85% RH (With no condensation) Shock
Item Unit Standard value Corrosion Scale generation pH (at 77F [25C]) 6.0 to 8.0 Tap Water (as Facility Water) Quality Standards Electric conductivity (25C) [S/cm] 100 to 300 The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water Standard item Chloride ion (Cl) [mg/L] 50 or less Sulfuric acid ion (SO42) [mg/L
) Battery life Response speed 250 ms 2% F .S. or less (Temperatue conditions: at 25C) Display accuracy 1% F .S. or less (Temperatue conditions: at 25C) Repeatability 3% F .S. or less (0 to 50C with 25C standard) Temperature characteristics Piping port M5 x 0.8 0 to 50C (With no condensation) Ambient operating temperature Ambient operating humidity 35 to 85% RH (With no condensation) Shock
Repeatability ISA2 Hysteresis mode Hysteresis Adjustable (can be set from 0) IS Window comparator mode Display 3 digit, 7-segment indicator, 2-color display (red and green) can be interlocked with the switch output, Sampling cycle: 5 times/s ZSM 2%F.S. 1 digit or less (at 25C 3C) Display accuracy Indication light Light up when output is ON (Green) PF2 Functions Anti-chattering function, Unit
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, GRIPPER PARALLEL W/DUST COVER, ACTUATOR, MHZ2 GRIPPER, PARALLEL, IC, 25MM MHZ2, 1.25514 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2)Mass(g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZJ2-25C25?831
. *2 Linearity 1% F.S. or less Current output Load impedance Maximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 Display 4-digit, 7-segment, 2-color LCD (Red/Green) Sampling cycle: 5 times/s Display accuracy 2% F.S. 1 digit (Ambient temperature of 25C) Indicator light Lights up when switch output is turned ON.
Temperature characteristics 2% F .S. (25C standard) Accuracy Output type Select from NPN or PNP open collector output.
25C 25C 1 Leakage: The value at a differential pressure of 0.01 MPa or higher and an ambient temperature of 20C 2 This product has an IP67 enclosure, but if water enters the product, it may result in malfunction or breakage.
2.5% F.S. or less (at 25C water)?1% F.S. or less (at 25C water)?5% F.S. or less (0 to 50C, based on 25C)Pulse outputAnalog outputAnalog output12 to 24 VDC (ripple ?
2.5% F.S. or less (at 25C water)?1% F.S. or less (at 25C water)?5% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2D 300/301(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output Note 5) 1 to 5 VLinearity: ?
2.5% F.S. or less (at 25C water)?1% F.S. or less (at 25C water)?5% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2D 300/301(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output Note 5) 1 to 5 VLinearity: ?
2.5% F.S. or less (at 25C water)?1% F.S. or less (at 25C water)?5% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2D 300/301(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output Note 5) 1 to 5 VLinearity: ?
Item CH1 CH2 Setting range 5 to 35 10 to 40 CH2 set temperature CH1set By default 20 25 temperature [Tips] Sample set temperature: To change from CH1SP: 25C and CH2SP: 30C status, to CH2SP: 15C, first set CH1SP to 15C and then CH2SP to 15C. If CH2SP is set to 15C before setting CH1SP to 15C, then the following message appears: Please set CH1SP first.
2.5% F.S. or less (at 25C water)?1% F.S. or less (at 25C water)?5% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2D 300/301(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output Note 5) 1 to 5 VLinearity: ?
acting 6 115 30 16 40 MHZ2-16D (N) 10 235 42 20 66 MHZ2-20D (N) Single acting type, normally open 14 430 65 25 104 MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S (N) 14 435 45 25 MHZ2-25S (N) 12 4 55 10 MHZ2-10C (N) 31 Single acting type, normally closed 6 115 16 MHZ2-16C (N) 56 10 240 20 MHZ2-20C (N) 83 14 430 25 MHZ2-25C
The suffix of the filter model part number is "X0". 5 Pressure loss: 0.01 to 0.02MPa Operating temperature: 0 to 70C Differential pressure resistance: 0.5MPa/25C Membrane CA element "ED111S ...
) 2% F.S. 1 digit (25C) Lights up when output is ON (Green) 2% F.S. or less (based on 25C) IP40 Operating: 0 to 50C; Stored: 10 to 60C (with no freezing or condensation) Display Display accuracy Indication light Temperature characteristics Enclosure Ambient temperature range Ambient humidity range Withstand voltage Insulation resistance Vibration resistance Impact resistance Port size Operating
The suffix of the filter model part number is "X0". 5 Pressure loss: 0.01 to 0.02MPa Operating temperature: 0 to 70C Differential pressure resistance: 0.5MPa/25C Membrane CA element "ED111S ...