switch 5 to 50C (No freezing) (Ex.)10-ARP30-02BE1 Bleed type Construction 0.2 0.5 Weight (kg) Note 3) 0.3 Note 1) When a product with backflow function (10-ARP20K to 40K) is chosen, set the inlet pressure 0.05 MPa or higher than the set pressure.
[When used for water] 10. Never mount a switch in a place that will be used as a scaffold during piping work. Damage may occur if subjected to an excessive load. Especially when the switch supports piping, do not apply a load of 15Nm or more to the metal part of the switch. 11.
Seal kit includes a grease pack (10 g). When !5 or !6 is shipped independently, a grease pack (20 g) is included. Order with the following part number when only the grease pack is needed. Grease pack part number: GR-S-010 (10 g), GR-S-020 (20 g) D-X Technical Data 1213 A MY1H Series Construction End lock !9 @2 @0 @1 e w !5 !6 !3 !2 !1 !0 q t r i S u y o !4 !8 !
) 14 (10) 32 (0) 50 (10) 68 (20) 86 (30) Atmospheric pressure dew point F (C) How to read the dew point conversion chart Example) To obtain the atmospheric pressure dew point at a pressure dew point 50F (10C) and a pressure 102 psi (0.7 MPa). 1.
For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3
3 I.D. 10.8 x 2.4 O-ring JIS B2401-4D-P11 FPM 4 Series FQ1 Dimensions Bracket 32 V-band support 2.3 75 (25) 50 100 (80) 75 70 70 30 50 10 92 7 2-A 10 108 R3.5 R8 127 (60) R25 120 109 Part number A Applicable bore size Rc 1 Rc 3/4 Rc 1/2 BP-13S BP-14S BP-15S 34.5 27.5 22 120 50 AIR VENT 10 G1/4 10 92 7 R3.5 2-Rc P 102 (43) A I N INLET OUTLET B (108) Intermediate holder Note) Installed only
Configure a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the driver 9. When not using the STO function, attach the short-circuit connector came with a driver. 10. When wires used for L11 and L21 are thinner than wires used for L1, and L3, use a molded-case circuit breaker. 11.
model that can provide a gripping force of 10 to 20 times the workpiece weight, or more.
Class22 A DC24 V 108 A () DC24 V +10/-5 Class22 A DC24 V +10/-58 A 1 IP67() -1050 -2060 3585%RH() AC500 V1 FE DC500 V10 M FE 3(UL508) CE UL(CSA)RoHS 170 g 175 g 1 EX600-ED2-31No.EX-OMN0029CN-D EX600-ED3-32No.EX-OMN0029CN-D (DC24 V10%) -33No.EX-OMN0029CN-D LED 0 1 LED Yes No SI 2 3 4 SI ST(M) 5 6 7 SI . -34No.EX-OMN0029CN-D SI 8 ST(M) ST(M) 9 / PWR PWR(V) 10
VQ4 VQ5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Connector wiring diagram (mixed wiring) VQZ 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 VQD 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2
3 I.D. 10.8 x 2.4 O-ring JIS B2401-4D-P11 FPM 4 Series FQ1 Dimensions Bracket 32 V-band support 2.3 75 (25) 50 100 (80) 75 70 70 30 50 10 92 7 2-A 10 108 R3.5 R8 127 (60) R25 120 109 Part number A Applicable bore size Rc 1 Rc 3/4 Rc 1/2 BP-13S BP-14S BP-15S 34.5 27.5 22 120 50 AIR VENT 10 G1/4 10 92 7 R3.5 2-Rc P 102 (43) A I N INLET OUTLET B (108) Intermediate holder Note) Installed only
Cylinder tube shape for 0.75, 106 K M1 O-counter bore R depth A + Stroke E 0.13 [0.16] Note 1) 2 sides x 4 places (Inch) C Symbol Bore 1/8"st 1/4"st 3/8" to 4"st A Z W R Q P O N M2 M1 K J I H E D 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.31 0.36 0.46 1.25 0.56 #10-32UNF 1.56 0.06 0.25 0.86 1.22 0.15 0.25 0.19 0.15 1.31 0.38 #10-32UNF 0.50 0.70 0.52 1.56 0.88 5/16-24UNF
A Note 1) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
type (D)/CJ5DS CDH9 +0.030 0 Cdd9 0.030 0.060 NB GA GB Piping port 2-M5 x 0.8 Clevis pin ( ) MM CA CB D NA A CX + 0.2 + 0.1 U BA S + Stroke Z + Stroke ZZ + Stroke BB H R (mm) CD (Cd) A BA BB CA CB CX D GA GB H MM NA NB R S U Z ZZ Bore size (mm) 10 15 15 12 17 14 3.3 3.2 4 8 18 28 M4 x 0.7 12.5 22.5 5 46 8 82 87 16 15 18 18 20 20 5 6.5 5 8 23 28 M5 x 0.8 12.5 27.5 8 47 10 85 93 Clevis pin
Thermo-chiller, Rack Mount, air cooled, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40 lb
Connector C Actuator side (Terminal no.) 1 2 5 6 (8) (14) (18) A1 B1 (13.5) (17.7) (17.7) Cable length (L) [m] 1 3 5 8 A B C 1 2 1.5 3 5 8 A6 B6 (30.7) Connector A 15 16 (14.7) Connector D L (11) (10) LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) 8 A B C Controller side 10 (14.2) Connector C (Terminal no.) 1 2 5 6 Step Motor (Servo/24 VDC) 15 (5.5) (6.3) Actuator
B Auto switch a b d c Proper mounting positions (mm) A B Bore size (mm) 63 80 100 10 13 17.5 14 18.5 23.5 Proper mounting positions (mm) a b 14 18 17 c 20 24 23 d D-A9 type D-F9 type D-F9 W type 2 6 5 8 12 11 In order that adjacent switches do not misoperate, they should be set within 1mm of the proper mounting positions indicated in the table above.
If an instantaneous flow of 10 L/min lasts for 5 minutes, the accumulated flow will be 10 x 5=50 L. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes.It is possible to calculate the total accumulated flow by counting the pulses.
6 to 8 (D, DL) Pg9 Pilot port 12 (P1), 10 (P2) Port size: refer to table below G (Air operated) H (Grommet: G) I (DIN terminal: D, DZ) Manual override (Non-locking push type) P2 P1 F E D B A A J B C Main port 1(A) (Back side 2 (B)) Port size: refer to table below Main port 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H I J Model VNB5-32A VNB6-40A VNB7-50A 1 8 1 4 1 4 1 4 1 2 1 1 2
From the point just found, draw a line to the Y-axis to find the air consumption. The result is approximately 10 L/min (ANR). Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.