An environment where food which will be sold as merchandize, directly touches the fitting components. Installable Splash zone An environment where food which will not be sold as merchandize, directly touches the fitting components. An environment where there is no contact with food.
VR VH VHS Construction VHS20/30 VHS40/40-06/50 6 8 7 2 2 5 5 1 4 IN OUT OUT IN 1 9 3 EXH. EXH. Component Parts No.
They do not guarantee an actual fixed range (expect approximately 30% dispersion).
port Nil TN 90 G 105 NPT 120 135 A015 C S CKZT Clamp Arm 40 Mounting hole Bore size 40 80 Equivalent Power clamp cylinder European type D1 H D2 D1 D2 H symbol S B 6 7 16 6 9 25 8 20 8 10.2 10.2 25 Bore size Only S type is available for A015 of 40. 40 80 40 Arm mounting position 80 Equivalent Right D1 D2 Offset H R A015 A045 Offset 15 Offset 45 Center D1 D2 C H Left D1 D2 L H Cylinder Specifications
AFF125A-30 IDF120D-3 AMD910-30 220 30.0 AT220C-40 AFF220A-40 IDF150D-3 50 Hz area 60 Hz area IDF1D-1 IDF2D-1 IDF3DIDF4DIDF6DIDF8DIDF11CIDF15CIDF22C1-3 IDF22C1-3 IDF37C1-3 IDF55C-3 IDF75C-3 IDF120D-3 IDF120D-3 IDF150D-3 AMD1010-40 AMH150-03 AMH150-03 AMH250-03 AMH250-03 AMH350-04 AMH350-04 AMH450-06 AMH450-06 AMH550-06 AMH550-10 AMH650-14 AMH850-20 AMH850-20 IDG10-03 IDG20-03 IDG30-03
200 to 230VAC B2 B1,B2 B1,B2 Without lock Nil Without lock Nil 400 400 40 40 S8 S8 Cable length With lock B With lock B Without cable Without cable Nil Nil Ball screw lead Stroke 2m 2 2m 2 Size Size 100mm 100 100mm 100 5m 5 5m 5 40 32 25 40 32 25 10m 10m A A 1000 1000mm 1000mm 1000 12mm 12mm 16mm 16mm 20mm 20mm A A The length of motor, encoder and lock cables are same.
Note 5) Air is normally being discharged to the atmosphere from a bleed hole or an exhaust port.
AS32l1F-U02-12A 12 18.5 29.7 40 34.5 17 42 AS32l1F-U03-06A 6 10.4 21.8 32.1 36.4 50 48.4 43.6 42 1/4 19 16.6 13.3 39 AS32l1F-U03-08A 8 13.2 22.7 33 14.2 AS32l1F-U03-10A 10 15.9 26.7 37 28 15.6 40 AS32l1F-U03-12A 12 18.5 29.7 40 26.8 17 42 AS42l1F-U04-10A 10 1/2 24 15.9 18.8 27.4 40.3 36.2 50.8 49.2 42.2 40.6 15.6 52 AS42l1F-U04-12A 12 18.5 30.8 43.7 35.1 17 54 AS42l1F-U04-16A 16 23.8 34.8
: 4-48 32 : 1-12 65 : M5 x 0.8 93 : M30 x 3.5 05 : 5-40 33 : 1 1/8-7 66 : M6 x 0.75 94 : M36 x 4.0 06 : 5-44 34 : 1 1/8-12 67 : M6 x 1.0 95 : M16 x 1.25 07 : 6-32 35 : 1 1/4-7 68 : M8 x 1.0 96 : M36 x 1.5 08 : 6-40 36 : 1 1/4-12 69 : M8 x 1.25 97 : M36 x 2.0 09 : 8-32 37 : 1 3/8-6 70 : M10 x 1.25 10 : 8-36 38 : 1 3/8-12 71 : M10 x 1.5 11 : 10-24 39 : 1-14 72 : M12 x 1.5 12 : 10-32 40 : 1
: 4-48 32 : 1-12 65 : M5 x 0.8 93 : M30 x 3.5 05 : 5-40 33 : 1 1/8-7 66 : M6 x 0.75 94 : M36 x 4.0 06 : 5-44 34 : 1 1/8-12 67 : M6 x 1.0 95 : M16 x 1.25 07 : 6-32 35 : 1 1/4-7 68 : M8 x 1.0 96 : M36 x 1.5 08 : 6-40 36 : 1 1/4-12 69 : M8 x 1.25 97 : M36 x 2.0 09 : 8-32 37 : 1 3/8-6 70 : M10 x 1.25 10 : 8-36 38 : 1 3/8-12 71 : M10 x 1.5 11 : 10-24 39 : 1-14 72 : M12 x 1.5 12 : 10-32 40 : 1
circuit 30 Nil E None With power-saving circuit 40 Electrical entry direction Orifice diameter Piping direction 45 left direction IN Symbol Series Orifice diameter (mm ) IN 1 3 4 6 1.0 3.0 4.5 6.0 30 L1 Nil 40 OUT OUT Quick Fastener Clip Part No. 90 left direction 45 right direction Series Size Quick fastener clip part no. (2 pcs.)
Switching valve kit KT-PAF3-37 Note) KT-PAF5-37 Note) Pilot valve kit KT-PAF3-38 KT-PAF5-38 Foot kit KT-PAF3-40 KT-PAF5-40 Leakage sensor KT-PAF3-47 KT-PAF5-47 606 Process Pump Automatically Operated Type/Air Operated Type PAF Series Piping and Operation: Automatically Operated Type (PAF3410, 5410) Piping diagram Reset button Air operated reset port PA Pilot air supply port AIR SUP Discharge
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident.
AS221FG-02 AS331FG-02 R(PT) 1/4 40, 50, 63 AS321FG-02 AS331FG-03 R(PT) 3/8 40, 50, 63 AS321FG-03 AS431FG-04 R(PT) 1/2 63, 80, 100 AS421FG-04 AS131FG-U10/32 10-32UNF 6, 10, 16, 20 AS121FG-U10/32 AS231FG-N01 NPT1/8 20, 25, 32 AS221FG-N01 Elbow type AS231FG-N02 NPT1/4 20, 25, 32, 40 AS221FG-N02 AS331FG-N02 NPT1/4 40, 50, 63 AS321FG-N02 AS331FG-N03 NPT3/8 40, 50, 63 AS321FG-N03 AS431FG-N04
oil odor. 3) Use the length of time calculated in step 2) as an approximate effective deodorization time.
Combination Spacer Select one of the spacers below when connecting to an F.R.L. combination unit (AC2000 to AC6000). (Spacers must be ordered separately.)
180 Angular Type Air Gripper Rack & Pinion Type MHW2 Series 20, 25, 32, 40, 50 How to Order M9BW 20 MHW2 D 1 Made to Order Refer to page 712 for details. 2 fingers Number of fingers 2 Number of auto switches Bore size 20 25 32 40 50 Nil 2 pcs. 20 mm 25 mm 32 mm 40 mm 50 mm S 1 pc. n n pc.
140.5 LVR50-V19 22 80 120 169 C F E Breathing port M5 x 0.8 J Tube extensions 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Breathing port M5 x 0.8 Model A B C D E LVR20-T07(06) 40 40 49.3 68 20.1 LVR40-T11(10) 82.5 82.5 89 115 33 IN C F Model F G H J K LVR20-T07(06) 8 27 56 33.5 126.2 LVR40-T11(10) 14 64.5 100 40 183.3 E K J J Breathing port M5 x 0.8 5 Applicable Fluids Regulator
For sonic range Where P1 = 0.10132 (P2 + 0.1013) Formula based on Cv factor Q = 98.9Cv (P1 + 0.1013) kg/h Formula based on effective area Q = 5.5S (P1 + 0.1013) kg/h 1 5 20 3 4 20 1 0 30 40 30 20 40 20 30 30 40 20 50 60 60 50 40 30 20 3 4 30 40 50 Figures inside [ ] indicate the saturated steam holding heat (kcal/kg). Figures inside ( ) indicate the saturation temperature (C).
If foreign matter is adhering to the parts, perform an appropriate procedure, such as blowing with air or cleaning with neutral detergent. Closing the valve: Turn 90 counterclockwise from the open state to the original state to close the valve. Perform an eletrical operation at the position where the valve is closed.