Since this will make it impossible to satisfy the specifications, operate with adjustment within the range of maximum values. 11-5-20 20 Rotary Table: Basic Type Vane Style Series MSUB These drawings indicate the condition when the B port is pressurized.

5, 10, 15, 20 5, 10, 15, 20 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27 BY 7 8 9 9 12 B 24 28 32 39 50 BX 9 6.5 8 10 11 ET M5 X 0.8 Depth 11 AL 19.5 23.5 27 32 32 BS 42 50 54 64 63 K 5.5 5.5 6 7 7 A 22 26 30 35 35 BT M5 X 0.8 Depth 7.5 M6 X 1 Depth 12 M6 X 1 Depth 11 M8 X 1.25 Depth 13 M8 X 1.25 Depth 11 M10 X 1.5 Depth 15 M10 X 1.5 Depth 14.5 M12 X 1.75 Depth 18 M12 X 1.75 Depth

20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 , , 1 4 3 8 40 40 50 50 55 55 65 85 , Misc.

20 stations P, R Port size 1/8 1/4 3/8 1/2 VFA1000 VFA3000 VFA5000 Symbol Up to 10 stations for VV5FA5-20, and up to 15 stations for VV5FA5-21. 30 20 21 The A and B ports are made on the top.

H L2 L1 M A E M LQ1L12-M LQ1L11-M 3 4 1/8 11.5 11.5 10 15 18 1/8" R (NPT) Port size Class 1 LQ1L43-M LQ1L42-M LQ1L41-M LQ1L36-M LQ1L35-M LQ1L34-M LQ1L33-M LQ1L32-M LQ1L31-M LQ1L24-M LQ1L23-M LQ1L22-M LQ1L21-M 12 10 12 6 8 10 6 8 10 4 6 4 6 1/8" L1 16.5 14.5 14 15 20.5 27 1/4" L2 (A) M 1/4" 23 1/4 20 17 20 26.5 35 H (E) 3/8" Class 2 to 5 Courtesy of Steven Engineering, Inc.-230 Ryan Way,

at 40 mA) Current leakage 100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.

<-III o ~ \ ~ r c-~~ ~ d" -, Rod end without L --' thread r~ \ A~OSW'tCh MM 8 NN LZ --' l S (Across H at) .. s .I w J 2051 3Gst 1561 I (mm) ,5 st lost ~ 1551 sst l. l0S" 20" 1.30>1. P .

Note 5) The analog output operates only for real-time flow rate, and does not operate for accumulated flow. 11 Digital Flow Switch Series PF2A For Air Flow Characteristics (Pressure Loss) PF2A703H PF2A706H PF2A712H 20 20 20 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 10 10 10 600 0 2400 4800 7200 9600 12000 150 0 600 1200 1800 2400 3000 300 0 1200 2400 3600 4800 6000 Flow

URL http://www.smcworld.com -10 V to 10 V -20 mA to 20 mA for 2 hours each in direction X, Y and Z respectively (De-energized) 24 VDC Class2, 2 A 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 0 V to 10 V 0 mA to 20 mA Content Content Content 0 V to 10 V 0 mA to 20 mA 0 V to 10 V 0 mA to 20 mA

P2 Time (Operating principle) At the point when the primary pressure fluctuates, the set pressure value is compensated by setting the auto shift input (external input) to low (no-voltage) input, using the pressure measured at that point as a standard.

P2 Time (Operating principle) At the point when the primary pressure fluctuates, the set pressure value is compensated by setting the auto shift input (external input) to low (no-voltage) input, using the pressure measured at that point as a standard.

110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 5.5 6 6 7 7 9 9 9 11 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 10 10 10 10 10 10 10 10 10 1 8 1 4 3 8 AMG150 , , 1 4 3 8 , AMG250 1 2 3 8

x 0.8 Vacuum port 28 27 10 4.5 J depth 1.5 3 6 +0.030 0 10 9.5 4 Section AA B D Mounting base side +0.030 0 Q QL depth 1.5 3 11-/22-MXP10-20 Without magnet and switch rail Max. 2.5 2 x M2 x 0.4 depth 3 8 2.5 4.7 15 15 L 6 x M3 x 0.5 depth 4 2 x M3 x 0.5 depth 3.5 (mm) G H J K L M N Q QL S V W Z Model 11-/22-MXP10-10 8 32 52.4 20 20 21 6.5 32 14 10 44 40 60 11-/22-MXP10-20 20 50 82.4 36

Refer to Flow Characteristics (page 14-20-44) and figure of Max. Air Flow (page 14-20-45).

stattons : l : 20 | 20 staitons Type /rc Nvv5z3-4o-@2g|5 Stations I asize of A, B port lils | 10.32 Nom.

For details about the Specific Product Precautions, refer to the Operation Manual at SMC website.

(coil temperature 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30msec occurs in the OFF response time.

Note 3) The maximum dimensions that appear are those measured at the maximum rotating angle. settings: 100 and 190.