SMC Corporation of America
Elite Part Number Search
Search Results "IDFA11E-23-AT"

Intermediate strokes For manufacture of strokes other than the standard strokes above, add "-X2" at the end of the part number.

P. 90 For polyurethane tube. 3.18/2 M3 Universal tee M5 male -M5 male M-5N Body rotates at 360 around the stud axis. M3 female -M3 female -M3 male For soft nylon and polyurethane tube. M-5ALU-4 4/2.5 M-3UT P. 92 Union nipple M-5ALU-6 6/4 Body rotates at 360 around the stud axis. P. 91 P.90 Nipple Barb elbow(H) Body rotates at 360 around the stud axis. M-5UN PAT.

While maintaining the upstream pressure at a fixed value above 0.3 MPa, measure the maximum flow to be saturated initially. Next, measure this flow rate at 80%, 60%, 40%, and 20%, as well as the upstream and downstream pressure. The sonic conductance C can be calculated based on this maximum flow rate.

Displacement exceeding the specified value is generated at the pushing start position. LEJ LEL 9. Return to origin 1) Do not apply a load, impact or resistance in addition to the transferred load during return to origin.

During the operating stroke at initial actuation, the cylinder moves at a slow speed from to due to the fixed throttle of the SSC valve. When it reaches , the head pressure (PH) rises quickly as indicated by the line from to .

applied to pneumatics only. 14-3-4 5 For details about certified products conforming to international standards, visit us at www.smcworld.com.

On RED LED at OFF ~ndicatorfAmp D-P70 Surge Suppressor i wire oil proof, flame retardant (VW-l). heavy insulated cable 06.8,0.75 mm2 , Reed Switch 2 wire (white and black), O.Sm* Impact proof, 300m/s~"* Insulation resistance SOmO or above (among lead wire and enclosure) at DC500V mega.

Do not weld an arm to the cylinder. 4) Always use a speed controller, and set it so that it takes at least 1 second from unclamped to clamped, and at least 1 second from clamped to unclamped. 5) This product is designed to be used after being adjusted using a shim.

Speed may be accurately controlled even at low speeds. Able to control and set a constant speed easily.

Connected to the fluid inlet at IN and to the fluid outlet at Bracket This is a mounting bracket used to install the product. -13No.LFE*-OMZ0012 Definition and terminology Term Meaning Outputs a value proportional to the flow rate. When the analogue output is in the range 1 to 5V, it will vary between 1 to 5V according to the rate of flow. The same for analogue output of 4 to -20 mA.

Low frequency operation Valves should be switched at least once every 30 days to prevent malfunction. (Use caution regarding the air supply.) 4. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating. Caution 1. Install air filters. Install air filters close to valves at their upstream side.

Green lights ON at optimum detecting position.

In addition, for the type with stoppers, confirm the lifting force at 1 mm. (For the type with a vibration suppression cover, confirm the lifting force at 1.5 mm.) For the ZNC40, as the lifting force is 5.5 N when the supply pressure is 0.4 MPa, the lifting force is greater than the required lifting force. Therefore, the product can be used.

Step 3 LEF * The duty ratio is a ratio at the time that can keep being pushed. LEJ Selection Example LEL Operating conditions Mounting condition: Horizontal (pushing) Duty ratio: 20 [%] Jig LEM Jig weight: 0.2 [kg] Speed: 100 [mm/s] Pushing force: 60 [N] Stroke: 200 [mm] LEY LEY LES Step 1 Check the duty ratio.

When more than 3 valves adjacent on the same manifold are energized at the same time, the valves will have a larger temperature rise on the coil and in such an application the use of the low wattage type (0.5W) will be recommended. 3 Energization time The double solenoid valve must be energized for at least 0.1 second to ensure proper operation.

Fluoropolymer Fittings Hyper Fitting/Flare type Series LQ3 Specifications LQ310 LQ320 LQ330 Model Material Max. operating pressure (at 20C) New PFA 1.0 MPa 0 to 150C 0 to 200C 3 to 25 1/8" to 1 1/4" Nut material: PVDF Operating temperature Nut material: PFA Metric Inch Applicable tube size Refer to Best Pneumatics No. 7 for further details.

2For DeviceNetTM Connects to the communication port of the communication unit connected at the end K !3 K !8 K !5For PROFIBUS DP K w For EtherNet/IPTM, PROFINET, EtherCAT, Ethernet POWERLINK K w and K e are used in combination with each other. K !

Applicable solenoid valves: Series SYJ314, SYJ314M, SYJ324, SYJ324M (SYJ300 3 port valve) (SYJ300 3 port valve) Plug (VJ3000-33-1) Plug (VJ3000-33-1) Seal the unused R port at the end the manifold. Seal the unused R port at the end the manifold.

the output number starts at the A side and then B side in that order as shown in the figure a.