Description Material Note Body Finger Piston rod Rack Pinion Pinion cover Pinion axis Piston Piston A Piston B Piston A Rod cover Bumper Clip Rubber magnet No.
51 (2.8) A, BEA, EB: 57.6 (3.2) [A, BEA, EB: 45 (2.5)] VFRA4311-04 3 8 VFRA4411-03 3 position exhaust center 1.2 1 8 PA, B: 51 (2.8) A, BEA, EB: 57.6 (3.2) [A, BEA, EB: 45 (2.5)] 1 2 VFRA4411-04 3 8 65 (3.6) [PA, B: 30.6 (1.7)] VFRA4511-03 3 position pressure center 1.2 1 8 VFRA4511-04 1 2 67 (3.7) [PA, B: 30.6 (1.7)] ( ): in case of normal position.
Description AQ2000 AQ3000 AQ5000 AQ1500 AQ1510 Valve 30093 NBR 30073 30053 30063 30083 r O-ring 9 x 7 x 1 JIS B 2401P-7 NBR CA40-1601 CA50-1602 30066 t Dimensions AQ1500/1510 AQ2000/3000/5000 3-port size (Mounting hole) 3-port size L1 L2 L3 L4 L5 L6 L7 L8 L9 D L1 L2 L3 L4 Model Port size AQ2000 Model Port size 1 8 1 4 M5 x 0.8 AQ1500 23 20 14 3 12.5 12 15 5.5 6.5 3.1 45 40 10 45 , 3 8 1 4
Inch Size Model Applicable tubing O.D. d T H D1 D2 D3 L1 L2 L3 A1 A2 Max. Max. Min. Min. Max. Min.
Description Body A Handle Body B Needle Seat ring Needle guide Material Note No.
(Values at the initial period) VQZ VZ VS VFN Base mounted Flow Characteristics/Weight Weight (kg) Flow characteristics P A Port size Rc C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv A E AC 0.34 0.34 0.40 0.40 0.32 Body type Valve model DC 0.46 0.46 0.52 0.52 0.44 VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00 1 8 1 4 1 4 3 8 2.5 3.6 3.2 3.6 0.39 0.34 0.31 0.18 0.86 0.86 0.93 0.94 0.66 0.88
L1 L2 VVX31 LQ VVX32 VVX33 LVN Z 59 62 64 W 83 99 106 X 47 48 51 Y 47 58 67 V 102 114 123 S 39 41 44 T 59 62 64 U 92 95 97 Q 23 25 28 L 6 9 9 M 45.5 50.5 50.5 N 20 23 25.5 K 36 46 46 F 33 34 34 H 24 25 25 J 30 40 40 D 22 24 24 A 40 44 44 B 20 22 22 C 9 10 10 Model VVX31 VVX32 VVX33 TI/ TIL PA PAX PB 17-3-91
B 0.2 A 0.2 Bore size A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 8.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
EX) Base: 6 stations, common EXH, A & B port Rc 1/2 VVPA450-061-04 1 pc. VPA4154-00 3 pcs. VPA4254-00 2 pcs. XT038N-4A 1 pc.
Part A Part B 5. Avoid using in a place where noise (electromagnetic wave and surge) is generated. Please take into consideration that the One-touch fittings for supplying air, need enough space for the air tubing to be easily attached/detached.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
The output number starts at the A side and then B side in that order as shown in figure a. If a single-solenoid valve is mounted on the standard wiring manifold, the output number for the B side solenoid valve is skipped. Custom wiring for the mixed mounting single-solenoid valves and the double-solenoid-valves can be specified with a Wiring Specification Sheet.
(Refer to fig. b) : Each bit of data sent from master (4 bytes) shows ON/OFF (0: OFF, 1: ON) of solenoid valve.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.
(Full span) Indication precision G46-10-02-SR A, B Fluid contact part cleaning (Wetted part) Precision cleaning General degreasing Be sure to read the precautions on page 14-11-15 for selection and installation.