Magnet: None, Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 150 (1 1/2"), Body Option: M (Male Rod End)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 075 (3/4"), Stroke: 150 (1 1/2"), Body Option: M (Male Rod End)
Magnet: None, Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 150 (1 1/2"), Body Option: M (Male Rod End)
Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 150 (1 1/2"), Stroke: 150 (1 1/2"), Body Option: M (Male Rod End)
Built-in Magnet: D (With Magnet), Mounting Style: B (Standard), Bore Size: 63mm, Stroke: 150mm, Rod End Thread: M (Rod End Male Thread)
Magnet: None, Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 400 (4"), Stroke: 150 (1 1/2"), Body Option: M (Male Rod End)
Accuracy: Basic Type, Size: 25, Motor Mounting Position: D (In-line), Motor Type: NM1 (Mounting Type M1), Lead Screw: B [LEY25, 6mm; LEY32, 8mm, (10); LEY63, 10mm], Stroke: 150mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included)
Accuracy: Basic Type, Size: 32, Motor Mounting Position: D (In-line), Motor Type: NM1 (Mounting Type M1), Lead Screw: B [LEY25, 6mm; LEY32, 8mm, (10); LEY63, 10mm], Stroke: 150mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included)
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type),
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: w/o Cable, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: Top Mounting Type, Lead: Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Stroke: 500mm
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: 1.5, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: Top Mounting Type, Lead: Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Stroke: 500mm
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: w/o Cable, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: Top Mounting Type, Lead: Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Stroke: 100mm
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: w/o Cable, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: Top Mounting Type, Lead: Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Stroke: 30mm
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: w/o Cable, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: Top Mounting Type, Lead: Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Stroke: 150mm
Controller Series: Programless Controller, Parallel I/O Type: NPN, I/O Cable Length, m: 3, Actuator Series: Rod Type, Size: 40, Motor Mounting Position: Top Mounting Type, Lead: Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Stroke: 150mm
Communication Plug Connector: Straight, Controller Mounting: Screw, Size: 40, Motor Mounting Position: Top, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke, mm: 250
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: A (10m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator