Cooling Capacity HRSE012-A-10-(T) [50 Hz] [60 Hz] 1600 1400 1600 Ambient temperature Ambient temperature 0 200 400 600 800 1000 1200 1400 25C Cooling capacity [W] Cooling capacity [W] 25C 600 800 1000 1200 HRS HRS 090 35C 35C 0 200 400 HRS 100/150 0 10 20 30 40 0 10 20 30 40 HRSH 090 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH HRSE018-A-10-(T) [50 Hz] [60 Hz]
1 8 0.33 0.19 1.4 0.28 0.12 1.2 VF VZS2250 13 or less 0.19 Double 1200 1 8 0.33 0.19 1.4 0.28 0.12 1.2 VFR Closed center VZS2350 22 or less 0.2 600 0.27 0.17 1.1 0.21 0.23 0.90 1 8 VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Exhaust center 3 position VZS2450
Unit: mm Maximum stroke Bore size (mm) Basic type, Rear flange type, Single clevis type, Double clevis type, Center trunnion type Foot type, Front flange type to 1400 (to 1600) to 1000 (to 1000) 125, 140 160 to 1400 (to 1600) to 1200 (to 1200) Auto switches are not available with steel tubing.
Magnet: Built-in Magnet, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: NPT, Stroke: 1200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Magnet: D (Built-in), Mounting: S (MS2, Side Lug), Bore Size: 150 (1 1/2"), Stroke: 1200 (12"), Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC22 (Viton Seals)
Magnet: Built-in, Mounting: Rear Flange, Bore Size: 2 1/2", Stroke: 12", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Detachable Rear Clevis, Bore Size: 2", Stroke: 12", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rear Flange, Bore Size: 1 1/2", Stroke: 12", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: None, Speed Control Type: Right Angle, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed
Magnet: Built-in, Mounting: Front Flange, Bore Size: 4", Stroke: 12", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 2", Stroke: 12", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 2 1/2", Stroke: 12", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Single Detachable Rear Clevis, Bore Size: 4", Stroke: 12", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: MS2, Side Lug, Bore Size: 1 1/2", Stroke: 12", Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 1200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Support brackets are not for mounting; use them solely for providing support. m 90 MY1C63 MY1C63 MY1C63 MY1C63 80 (1600) (1600) (1600) (1600) (1600) (1600) 70 MY1C50 MY1C50 MY1C50 MY1C50 MY1C50 MY1C50 l l 60 (1400) (1400) (1400) (1400) (1400) (1400) MY1C40 MY1C40 MY1C40 MY1C40 50 MY1C32 MY1C32 MY1C32 MY1C32 MY1C32 MY1C32 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1C25 MY1C25 MY1C25 MY1C25
Work load [kg] Work load [kg] 40 30 Lead 8: LEY32DB Lead 10: LEY32B 30 20 24 19 Lead 16: LEY32DA 20 Lead 20: LEY32A 10 12 9 10 0 200 400 600 800 1000 1400 1200 0 0 200 400 600 800 1000 1200 0 Speed [mm/s] Speed [mm/s] LEY63 (Motor mounting position: Top/Parallel, In-line) 120 Lead 2.86: LEY63L (Top/Parallel type only) 100 Lead 5: LEY63C Work load [kg] 80 Area where the regeneration option
-F 100 200 300 400 500 600 700 800 900 1000 1200 245.7 345.7 445.7 545.7 645.7 745.7 845.7 945.7 1045.7 1145.7 1345.7 400 500 600 700 800 900 1000 1100 1200 1300 1500 50 150 250 350 450 550 650 750 850 1050 70 170 270 370 470 570 670 770 870 1070 Note) Dimensions inside ( ) are for a 100mm stroke. 4 Series LG1H High Rigidity Direct Acting Guide Type LG1H20: Without Coupling / Construction
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
Double acting single rod Fluid Air Proof pressure 1.5MPa Maximum operating pressure 1.0MPa Minimum operating pressure 0.05MPa Without auto switch: 10 to 70C, With auto switch: 10 to 60C Ambient and fluid temperature Cushion Rubber bumper, Air cushion 50 to 1000mm/s 20 to 63 Piston speed 80, 100 50 to 700mm/s Thread tolerance JIS class 2 +1.4 0 +1.5 0 +1.4 0 +1.5 0 20 to 63 to 1000 mm, to 1200