Insertion force [N] (reference value) Working pressure [MPa] Insertion depth [mm] AKP-*-*01 AKP-*-*02 0.1 5.1 6.6 0.3 7.5 11.3 0.5 10.0 16.0 0.7 12.4 20.8 2.4 (12) After operating the residual pressure exhaust button, confirm that the button has returned to the normal position.
If necessary, re-application of power supply should be done when 5s or more passes after PWR indicator lamp goes off. 28 3.Stroke learning General 3 positions 5 positions General 3-1 By push of over 3s at least, the product comes into learning mode and starts stroke learning. 3-2 Confirm 2 indicator lamps MOTOR and END are blinking.
data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 L L L L SOLV L L L L L L L L L L L L: Low fixed (0) Input status area Input status area specifications Item Status State 0 Normal SOLV State of power supply for solenoid valve 1 Abnormal (19 V or less) Output area mapping For EX260-SEN1/-SEN2 Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28
Abnormal driver parameter 28 A driver parameter abnormality in the controller system has occurred. Unsuccessful home position return 30 Trying to execute a program/step without completing the setup (home position return). No designated speed 31 No speed designation with MOVA or MOVI, and no prior speed designation found.
Stroke F(N) F(N) 9 15 105 110 115 14 120 125 130 8 13 140 150 175 7 12 5 200 11 Number of auto switches mounted Rotation Linear motion 2 0 0 1 0S 02 S0 S2 SS 1 20 n0 2 2S nS n2 n Combinations of made to order products No.1 to 4 are available. Consult SMC for further information. 1.5-19
Refer to the above drawing for other dimensions. n L 1 38 28 2 57 47 3 76 66 4 95 85 5 114 104 6 133 123 7 152 142 8 171 161 9 190 180 10 209 199 11 228 218 12 247 237 13 266 256 14 285 275 15 304 294 16 323 313 17 342 332 18 361 351 19 380 370 20 399 389 L1 L2 4-5-9 10 Series VK300 Precautions Be sure to read before handling.
VK300-37-2-01 VK300-37-2-02 VK300-37-2-07 VK300-37-4-51 VK300-37-4-06 VK300-37-3-05 VK300-37-3-53 A1 A2 A3 LW06 LW2 LD4 LD8 100 VAC 200 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC 4-13-3 4 For details about the applicable products conforming to international standards, visit us at www.smcworld.com. 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 5-Rc 1 1/4, 1 1/2 12 14 VPA42706-Rc 1/4 pilot port 5-3-28 5 Series VPA450 Manifold Specifications Specifications Manifold type Exhaust type Supply type Stations B mount Common exhaust, Individual exhaust (1) Common supply port Max. 10 stations (VVPA460
Note) A/B port piping: Rc 3/8 or Rc 1/2 Option VFS 9 Other Base specifications Individual EXH VS4 1 2 Individual EXH Common EXH Valve stations 02 2 stations VQ7 10 10 stations EVS How to Order Manifold Assembly VFN Specify the valves and blanking plate to be mounted on the manifold along with the manifold base model no.
(mm) H2 Q P L W H1 Model TMA-06 TMA-08 TMA-10 TMA-12 28 21.7 172.5 31.8 25.4 151.2 35 28.1 167.3 37 19 151 17.9 20.3 24.3 26.7 18.6 18.6 22 22 11.4 12.6 15 16.2 6 12 10 8 15-6-32 1 Related Products: Tube Cutter Series TK Tube Cutter: TK-2 Possible to cut a tube up to 18 mm.
Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type]
Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type], Lead Wire: N (None)
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type], Lead Wire: N (None)
Sensor Range: 5 [For Positive Pressure (0~2MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type]
Sensor Range: 5 [For Positive Pressure (0~2MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type], Lead Wire: L [w/Lead Wire and M12 Connector, (3 m), Right Angle]
Sensor Range: 6 [For Positive Pressure (0~5MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type]
Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type], Lead Wire: L [w/Lead Wire and M12 Connector, (3 m), Right Angle]
Sensor Range: 7 [For Positive Pressure (0~10MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type]
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: 28 [Current Output (4~20mA) Type]