MA B D-A9V D-F9V D-F9WV Auto switch mounting heights (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL SMC D-A90V SMC D-A90V MA MA MA 20 25 25.5 27.5 25.5 27.5 28 30 A Approx.
Metal stopper Reed switches (2 wire, 3 wire) Solid state switches (2 wire, 3 wire) 2 color indication solid state switches (2 wire, 3 wire) Auto switches +1 0 mm Stroke length tolerance Theoretical Output MXP16 (N) Operating pressure (MPa) Cylinder bore size (mm) 6 10 12 16 Piston area (mm) 0.2 6 16 23 40 0.5 14 40 57 101 0.7 20 55 79 141 0.4 11 32 45 80 0.3 8 24 34 60 0.6 17 47 68 121 28
/My max. 0.3 Stroke (mm) Stroke (mm) 10 15 20 25 30 5 25 30 10 15 20 5 0.2 MXPJ6 3.5 2.6 2.3 1.4 MXP10 4.2 8.5 1.7 6.3 50 100 200 300 500 700 MXP12 9.8 17 13 4.5 Average speed Va mm/s Collision speed V mm/s MXP16 26 41 28 12 1 Nm = 0.7375 ftlbf Note) Average speed is used at static moment calculation. Collision speed is used at kinetic moment calulation.
M2 M3 m1 m2 m3 16 25 40 16 25 40 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 100 120 100 38 35 35 MY2HT 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
52 35 14 9 M10 x 1.5 69 5 24 18 40 5.5 M6 x 1.0 9 Rc1/8 26 14 10 5.5 7 4.5 57 14 40 118.5 96.5 16 35 64 37 14 12 M10 x 1.5 86 7 30 22 50 6.6 M8 x 1.25 11 Rc1/4 30 17 14 3 8 5.5 71 19 50 45 M16 x 2.0 84 130 102 21 77 39.5 16.5 15 103 7 36 28 60 9 M10 x 1.5 14 Rc1/4 36.5 21.5 18 4.5 10.5 6.5 19 63 9 3 Position Cylinder Series RZQ Foot type/RZQL Foot type (mm) B + Full stroke L Bore size (
Analog torque limit 10V/max. torque TLA 27 LG 28 SD Plate 2m max. Personal computer (Note 9) MR Configurator (Note 10) USB cable CN5 (option) (Note 1) Refer to LECSB Operation Manual, section 3.2 for wiring details.
Operating environment .28 5-7. Lubrication .28 6. Maintenance or inspection .28 6-1. Maintenance or inspection .28 6-2. Replacement part .29 6-3. Maintenance .29 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -X () -S/-R () NPN 2 Max.28 V80 mA 1 V -21No.PS-OMU0005CN-C -V/-T () PNP 2 Max.80 mA 1 V T15 V 1 k V420 mA 12 V 300 24 V 600 50 -V/-T () PNP 2 Max.80 mA 1 V -Y () -V/-T () PNP 2 Max.28 V80 mA 1 V -22No.PS-OMU0005CN-C [] 3 0.2 [] / OUT2 OUT2 OUT1 OUT1 [F10]30 () 13 35 1 (62 ) ()
V80 mA 1 V FUNC DC(-) DC(+) OUT -P PNP 1 Max.80 mA 1 V FUNC DC(-) DC(+) OUT1 OUT2 -A NPN 2 Max.28 V80 mA 1 V FUNC DC(-) DC(+) OUT1 OUT2 -B PNP 2 Max.80 mA 1 V FUNC DC(-) -19No.PS-OML0002CN-G DC(+) OUT1 -C OUT2 NPN 1 Max.28 V80 mA 1 V 1 k FUNC DC(-) DC(+) -D OUT1 NPN 1 Max.28 V80 mA 1 V 12 V 300 24 V 600 50 OUT2 FUNC DC(-) DC(+) OUT1 -E OUT2 PNP 1
17 ON CC-Link Ver.1.00 130 -12No.EX-OMP0004CN-I PWR INM12 5 B codeSPEEDCON 1 SV24 V +24V 2 SV0 V 0 V 3 SI24 V +24 V 4 SI0 V 0 V 5 M12 SPEEDCON SPEEDCON SPEEDCON 1/2 SPEEDCON M12 -13No.EX-OMP0004CN-I SV SI DC24 V /28 SV DC24V SI DC24V A.
Lead wire length ZS-37-A ZS-28-CA-4 1 ZS-28-CA-4 1 1 3 m OUT2 OUT1 U P SET DOWN e-con connector Lead wire with M12 connector PF2A7 (H) PF2W7 (T) PF2A20 PF2W20 Lead wire with M12 connector PF2A5 PF2W5 (T) In addition to the connectors shown above, those listed below (e-con) can be connected.
32 L 250 290 LD 11 14 LH 57 65 LL 87 100 LW 168 200 M 15 16 N 47 50 NC 44 60 NE 122 147 NH 60 70 Bore size (mm) 50 63 SS 10 13 NW 118 142 PA 120 140 PB 186 220 PG 10 12 PP 26 42 Q 380 436 QQ 28 30 QW 90 110 RR 35 49 TT 35 43 UU 24 28 VV 28 30 W 200 236 WW 22 25 YW 128 152 Z 424 490 Bore size (mm) 50 63 Hole Size for Centralized Piping on the Bottom (Mounting side should be machined to these
VDW1: VDW10S-12A-1 VDW2: VDW20S-12A-1 M U Y W X 11 Size 39 VDW1 VDW2 11 28 17 34 15 33 20 14 Enter symbols in the order to the right when ordering a combination of electrical option, other options, and bracket interchangeable with old type. Example) VDW Z Z 1A XB 2 0 A Electrical option Bracket interchangeable with old type Other option Construction Normally closed (N.C.)
T) LVQ LQ (mm) Dimensions PB LVN T U Model LVD2-S LVD3-S LVD4-S LVD5-S PA 28 9.6 TI/ TIL 34 17.5 A B 35 20 U PA 57 25 PAX With flow rate adjustment & by-pass PB (Max. S) (Max.
1.5 125 125 B12 M12 x 1.75 B16 M16 x 1.5 Pad type Material HB Large bellows pad N NBR S Silicon rubber U Urethane rubber F Fluoro rubber E EPR 13-11-86 5 Series ZPT Vacuum Pad: Large Size Bellows Type Vertical Vacuum Entry without Buffer 63 80 63 80 ZPT HB-A14 (Male thread) ZPT HB-B (Female thread) M14 x 1 Rc 1/8 Hexagon width across flats 19 5 5 25 Hexagon width across flats 19 G 28
OJ 1A22x1.5 2. 1I 1 8 --g07D 28-03 ~ , Y-G08 80 71 23 038 SO r.122x15 21 27 lS'g.070 28 ~ 3 ~, 56 84 IV -GOS ~iTt .1 , m_ , m , L , CQ2 Double Rod Clevis Pin (mm) C02 Jam Nut J r ,..,. No. AppI_ bon~.. Dd9 L d I m 1 Soap ring ly-(l05 50,63 14
D-M9B D-M9N, D-M9P D-A93 Load voltage Load current range Indicator light Application 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905 Rotary Actuator 11-CRA1-Z Rotation
M4 x 0.7 Piping port F QL 6 13.5 Prepared hole diameter 3.3 2 x M3 x 0.5 (Plug: M-3P) 170.05 6 (fitting seat surface dimension) M3 x 0.5 Vacuum suction port Stroke: S M 1 Mounting base side B D Piping port A 2 x M3 x 0.5 A 5 5.5 3.2 J 2.4 Z Section AA 3.5 depth 2 2.5 +0.030 0 7 +0.030 0 depth 2 2.5 Q QL 11-/22-MXPJ6-10 4 x M3 x 0.5 depth 3 F (mm) E F H J M Q QL S Z Model 23 25 38 27 37 28
Load voltage 24 VDC,100 VAC 24 VDC (10 to 28V) 28 VDC or less Load current range Indicator light 5 to 40mA, 5 to 20mA 5 to 40mA 40mA or less D-Z73 D-Y59B D-Y59A Air cylinder Rotary actuator Air gripper Directional control valve Fittings & Tubing Pressure switch Clean gas filter Flow control equipment Filter, Pressure control equipment Air preparation equipment 2-wire type 3-wire type Solid
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Allowable temperature range (C) 10 to 80 Effective atmosphere Non-water soluble cutting oil 4.22 4.22 8.73 11.57 22.16 8.73 Extended Spring force (N) 6.18 6.86 14.61 17.65 38.05 14.12 Retracted 26 26 70 150 365 70 Basic type With cap Weight (g) 28 28