200 When 20 units are used 77% reduction Current model IR3000 Series 91% reduction 38000 yen reduction 150 150 117000 yen reduction Current model IR1000 Series IR2000 Series 100 100 IR1000-A Series IR2000-A Series IR3000-A Series 50 50 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Units used Units used Released into atmosphere IR Special bleeding structure No fixed throttle in the new design.
H 4 S y m b o l consumption (W) 100 VAC 200/40 Initial power / Power 200 VAC 800/40 Heater assembly number XLA25-60S-1 XLA25-60S-2 No. of heater assemblies 1 pc. 1 pc. H 5 100 VAC 200/40 400/70 Initial power / Power consumption (W) 200 VAC 800/40 1600/80 Note 1) Initial power and power consumption are nominal values. The heaters are PTC thermistor type design.
Note 1) 1 1/4B 90 1 1/2B 120 Note 2) 2B 200 2 1/2B 315 3B 450 Description Part no.
HOW Replacement Element Part No. 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) Element size Port size (Nominal size) 04 (1/2B) 06 (3/4B), 08 (1B) 10 (1 1/4B), 12 (1 1/2B) 16 (2B) 20 (2 1/2B), 24 (3B) 28 (3 1/2B), 32 (4B) 65 x 90 85 x 110 100 x 160 120 x 180 140 x 200 180 x 260 EM001H-074N EM101H-074N EM201H-074N EM301H-074N EM401H-074N EM501H-074N EM001H-105N EM101H-105N EM201H-105N EM301H
Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VZS VFS VS4 VQ7 EVS Large capacity EVS7-6 (Size 1) 1200 l/min (ANR) EVS7-8 (Size 2) 3000 l/min (ANR) EVS7-10 (Size 3) 5500 l/min (ANR) VFN Cylinder driving size Flow rate 100 160 200 Rubber seal, single type Lightweight Size 1 (3 position): 0.55 kg Size
How to Order Pilot Valve Assembly 1 G 00 VT3112 Rated voltage Electrical entry Note) 1 100 VAC, 50/60 Hz Grommet G 2 200 VAC, 50/60 Hz Note) Even if the electrical entry of the solenoid valve is T, D, TL, or DL, the electrical entry for pilot valve assembly is chosen for G. 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option 3-6-1 2 Series VP450
25, 50, 75, 100, 125, 150, 175, 200 12 20, 25, 32, 40 16 Strokes other than the above are produced upon receipt of order. 20 Stud Bolt Part Numbers 25 32 Bore size (mm) Part no.
80 300 300 1.0 RS1H80 RS1H50 200 200 RS1H63 0.9 Operating pressure P [MPa] 0.8 100 100 0.7 10 20 30 40 10 20 30 40 0 0 0.6 Transfer speed [m/min] = 0 Transfer speed [m/min] = 0.1 0.5 0.4 Graphe Graphr Bore size 20, 32/ = 0 Bore size 20, 32/ = 0.1 0.3 0.2 0.1 80 80 0 5000 1000 2000 3000 4000 Lateral load F [N] 32 70 70 60 60 50 50 32 40 40 30 30 20 20 20 20 10 10 0 0 10 20 30 40 10 20
EDS Enable (SC_MonSs) 1 Disable Enable (Inrush) 100 msec 2 Disable 0.1 ms 1.0 ms 1.0 ms 10 ms 20 ms 3 (Filter_T) 1.0 ms 15 ms 15 ms 100 ms 200 ms 4 (SigExt_T) Enable (SC_MonOp) 5 1 Disable Auto (SC_RstOp) 6 Manual Enable 7 (OC_Mon) 6 Disable Clear OFF 2 6 Hold 8 (Fault_MD) ForceON ON Clear OFF 2 3 6 Hold 9 (Idle_MD) ForceON ON ON Enable Val165000
150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read the graph The sonic range pressure to generate a flow rate of 500 l/min (ANR) is P1 0.14 MPa for a 6 orifice (VX2 4), and P1 0.3 MPa for a 4.5 orifice (VX23). 3 2 For Saturated Steam [663] (179
Insulation type Electrical entry Electrical option Class B G C D, T S Note) S L, Z 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) AC DC Note) Surge voltage suppressor is attached in the middle of a lead wire. 17-3-72 3 The VX series will be revised shortly.
Condition: Pressure 0.5MPa, Load 50%, Piping length 5m Effective area mm 2(Cv ) Cylinder speed (mm/s) 50 63 80 100 125 140 Bore size (mm) 160 180 200 250 300 Port size Rc(PT) 40 250 25(1.4) VEX312 -01, 02 500 750 02 ( 1 4) 60(3.3) 250 500 750 250 500 750 500 750 1000 500 750 1000 250 500 750 250 500 750 VEX332 -02, 03, 04 Body ported Base mounted 03 (3 8) 160(8.9) VEX350 -04, 06, 10 06 (3
Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40
RSH80 RSH80 RSH80 200 200 RSH63 RSH63 RSH63 RSH50 RSH50 RSH50 0.9 Operating pressure : P (MPa) 100 100 0.8 0.7 0 0 10 20 30 40 10 20 30 40 Load speed : u (m/min) m=0.1 0.6 Load speed : u (m/min) m=0 0.5 0.4 Graphe Graphr Bore size 20, 32/ m =0 Bore size 20, 32/ m =0.1 0.3 0.2 0.1 80 80 1000 2000 3000 4000 5000 0 32 Lateral load: W (N) 70 70 60 60 50 50 Weight : W (kg) Weight : W (kg) 32 40
VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase 110 VAC (50 Hz) Single phase 200 VAC (50 Hz) 200 to 220 VAC (60 Hz) Single phase 220 VAC (50 Hz) 0 F G N NPT 1 5 6 134 Heatless Air Dryer ID Series Working Principle Flow Rate Inlet pressure: 0.7 MPa Pressure drop (MPa) HAA HAW The compressed air that flowed in from the IN side passes through the 4 port solenoid valve, and after it is dehumidified
Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40
150 200 250 300 IRV Flow rate (L/min (ANR)) Inlet pressure (MPa) VEX ARP30(K) ARP30(K) Rc 3/8 SRH 0.50 0.25 SRP 0.45 0.40 SRF Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point VCHR 0.30 ITV 0.20 0.25 0.20 IC 0.15 ITVX 0.10 PVQ 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 VEF VEP Flow rate (L/min (ANR)) Inlet pressure (MPa) VER ARP40(K) ARP40(K) Rc 1
150 200 250 300 IR Flow rate (L/min (ANR)) Inlet pressure (MPa) IRV ARP30(K) ARP30(K) Rc 3/8 VEX 0.50 0.25 SRH 0.45 0.40 SRP Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point SRF 0.30 ITV 0.20 0.25 0.20 IC 0.15 ITVH 0.10 ITVX 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 PVQ Flow rate (L/min (ANR)) Inlet pressure (MPa) VY1 ARP40(K) ARP40(K) VBA VBAT
NPN) C76 IC 5 V Grommet C73 B54 C73C A33A A34A A44A B59W H7A1 H7A2 H7B H7C G39A K39A H7NW H7PW H7BW H7BA H7NF 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Yes Connector 12 V 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC Grommet DIN terminal Diagnostic indication (2-color) 3-wire (NPN) 3-wire (PNP) IC 5 V, 12 V Grommet 12 V 2-wire Connector 3-wire (NPN) 2-wire