Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80, 100 R 1/2 AS121F-U10/

Refer to back page 50 for Safety Instructions and pages 3 to 9 for 3/4/5 Port Solenoid Valve Precautions. 1474 4/5 Port Air Operated Valve SYJA3000 Series Specifications Fluid Air 0.15 to 0.7 100 kPa to 0.7 100 kPa to 0.7 2 position single Operating pressure range MPa 2 position double SYA 3 position 2 position single Operating pressure to 0.7 0.1 to 0.7 0.2 to 0.7 Note 1) Pilot pressure

-46No.PF-OMS0001CN-A [F20] [---] =00 = ON EEPROM 100 +100 OFF <> [F20] [iNP][] [iNP][-] [inP] [] [F20] GND 30 msec.

500 100 500 1 1 200 1000 200 1000 2 2 A-miniB type 50 200 50 200 3 3 CN2 CN2TB/PC 27 - 6.CN4 6.1 No.

Microspeed Cylinders CJ2X/CUX/CQSX/CQ2X/CM2X (10, 16) (10 to 32) (12 to 25) (32 to 100) (20 to 40) Clean room compatible Series 10-/11Achieves stable low speed operation even at 0.5mm/s (1mm/s for 16 bore size or smaller) Minimum operating pressure reduced (Low friction characteristics improved) Series CQ2X now includes four brand-new large bore sizes: 50, 63, 80, and 100.

Max. operating pressure Note 1) 2R (MPa) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Note 1) Note 2) Min. bending radius 100 15 25 30 50 65 13 20 24 30 40 50 60 Min. bending radius (mm) Note 3) Fixed end Bending value (Reference) 75 12 20 23 40 48 10 15 18 23 30 40 45 40 to +100C, Water: 0 to +70C (No freezing) Nylon 12 Operating temperature

28 40 33 50 33 50 0.7 0.5 1 2 VC 3 4 1.0 0.8 VDW 1.4 1.2 1 VQ 1 4 1 2.4 2.2 VX2 5.2 5.0 32 VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 2 1 3.8 3.6 VX3 7.0 6.8 40 JIS Symbol Valve type Operation N.C.

VQZ3000 0.9 1.2 Bore size (mm) Cv Cylinder speed (mm/s) Series CJ2 Series CM2 Series CA1 Base mounted (With sub-plate) 6 10 16 20 25 32 40 40 50 63 80 100 150 300 V V VQZ1000 Body width 10 450 0.35 V V V 600 750 150 300 VQZ2000 Body width 15 0.7 450 V V V V V 600 750 150 300 VQZ3000 Body width 18 1.2 450 V V V V V 600 750 Cylinder speed marked with V can be controlled by speed controller.

rate 40 40 40 10 10 20 20 20 20 5 5 10 0 0 0 0 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 2 4 6 8 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 2 4 6 8 10 12 14 16 Suction flow rate [L/min(ANR)] Suction flow rate [L/min(ANR)] Supply pressure [MPa] Supply pressure [MPa] ZU07SA Exhaust Characteristics Exhaust Characteristics Flow Rate Characteristics Flow Rate Characteristics ZU07LA 100 80 100 50 60 50 Vacuum

Table 7-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or

Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !

Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !

42.3 91 116 1 2 SMC 4 x 6.5 (Mounting hole) 80 OUT IN 100 6 HEX.35 (178) With nut 80 Pilot port Rc, NPT 1/8 12 R 132 100 116 1 2 SMC 4 x 6.5 (Mounting hole) 80 100 SRF50 19 Model A1 A2 B1 B2 OUT IN SRF50S-1S19 SRF50S-1S1925 SRF50S-1S25 SRF50S-1S2519 SRF50S-2S19 42.3 91 58 91 58 91 55 98 55 98 55 98 A1 A2 58 91 6 B1 B2 56 95 56 95 Tube extensions 80 Pilot port Rc, NPT 1/8 12 R 132 100

L/min) 100 120 0.3 MPa 90 Set pressure 0.4 MPa 100 Flow rate {L/min (ANR)} Flow rate {L/min (ANR)} 80 70 80 60 0.2 MPa 50 60 40 40 30 20 20 10 0.1 MPa 0 2 4 6 8 10 0 0.1 0.2 0.3 0.4 0.5 Number of needle rotations Fluid pressure (MPa) LLB4-1-P1R1VSF: High Flow Type (500 L/min) 500 600 Set pressure 0.4 MPa 0.3 MPa 500 Flow rate {L/min (ANR)} Flow rate {L/min (ANR)} 400 400 300 0.2 MPa 300

Bore size System Average speed [mm/s] MB, CA2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 500 mm 40 50 63 80 100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal A 1000 900 800 700 600 500 400 300 200 100 0 B 1000 900 800 700 600 500 400 300 200 100 0 C Bore size System Average speed [mm/s] CS1/CS2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 300 mm 125 140 160

Piston Speed Cushion Mounting types Air 250 psi (1.75 kgf/cm) 8 psi (0.06 kgf/cm) 40 ~ 140F (5 ~ 60C) 2 ~ 20 inch/sec (50 ~ 500mm/sec) Air Cushion Standard Basic, Foot, Flange, Center Trunnion, Side Tapped 3 positions can be obtained from a single cylinder.

RSH80 RSH80 RSH80 200 200 RSH63 RSH63 RSH63 RSH50 RSH50 RSH50 0.9 Operating pressure : P (MPa) 100 100 0.8 0.7 0 0 10 20 30 40 10 20 30 40 Load speed : u (m/min) m=0.1 0.6 Load speed : u (m/min) m=0 0.5 0.4 Graphe Graphr Bore size 20, 32/ m =0 Bore size 20, 32/ m =0.1 0.3 0.2 0.1 80 80 1000 2000 3000 4000 5000 0 32 Lateral load: W (N) 70 70 60 60 50 50 Weight : W (kg) Weight : W (kg) 32 40

350 0.7 DC DC VXF 2160 5 to 60 580 VC 1.0 AC AC 10 to 60 VXF2160 VXFA2160 1.0 0.03 330 2.0 1 27 VXFA 2160 5 to 40 400 0.7 DC DC VDW Solenoid type VXF 2280 5 to 60 1.0 1500 AC AC VXF2280 VXFA2280 VQ 10 to 60 1.0 0.03 810 2.0 40 1 2 1 VXFA 2280 5 to 40 0.7 1300 DC DC VX2 Note 1) Dew point shall be 10C or less.

600 700 800 900 Flow rate (L/min (ANR)) Inlet pressure (MPa) 705 Series ARP20/30/40 Construction ARP20(K)/30(K)/40(K) ARP20K/30K/40K (With backflow function) r q 1 I N e A 2 OUT A IN OUT t BLEED A-A w y Note Component Parts Material No.

700 800 900 Flow rate (L/min (ANR)) Inlet pressure (MPa) 763 ARP20/30/40 Series Construction ARP20(K)/30(K)/40(K) ARP20K/30K/40K (With backflow function) r q 1 I N e A 2 OUT A IN OUT t BLEED A-A w y Note Component Parts Material No.