SMC Corporation of America
Elite Part Number Search
Search Results "MGPM40-200AZ-XC8"

Bearing Type: Slide Bearing, Bore Size: 40mm, Port Thread Type: Bore 12,16: M5 x 0.8; Bore 20-100: Rc, Stroke: 75mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Bearing Type: Slide Bearing, Bore Size: 40mm, Port Thread Type: Bore 12,16: M5 x 0.8; Bore 20-100: Rc, Stroke: 100mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Bearing Type: Slide Bearing, Bore Size: 40mm, Port Thread Type: Bore 12,16: M5 x 0.8; Bore 20-100: Rc, Stroke: 40mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Bearing Type: Slide Bearing, Bore Size: 40mm, Port Thread Type: Bore 12,16: M5 x 0.8; Bore 20-100: Rc, Stroke: 50mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Bearing Type: Slide Bearing, Bore Size: 40mm, Port Thread Type: Bore 12,16: M5 x 0.8; Bore 20-100: Rc, Stroke: 25mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Bearing Type: Slide Bearing, Bore Size: 40mm, Port Thread Type: Bore 12,16: M5 x 0.8; Bore 20-100: Rc, Stroke: 400mm, Air Cushion: Air Cushion, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 0.5, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 5, The number of the switches:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9BAV, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 5, The number of the switches:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9NV, Lead Wire Length(m): 0.5, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9NWV, Lead Wire Length(m): 5, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: P5DW, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 5, The number of the switches: