SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-V-M5-W"

Body/Exhaust Type: For Manifold - Common Silencer Exhaust, Nominal Nozzle Size: ø1.0, Supply Valve and Release Valve: w/o Valve, w/o Energy Saving Function, Rated Voltage: None, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire, Vacuum, V Port: 06 [ø6 One-touch

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: w/o Option

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: w/o Option

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: w/o Option

. / None, Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: w/o

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: w/o Option

Applicable model M-5N AS1000 Nipple Note) AS1000 with nipple: AS1000-M5-N How to Order M5 AS 1 000 Option Body size H (1) High temperature (5 to 80C) 1 2 3 4 5 M3, M5 standard L (2) Low temperature (30 to 60C) 1 8 1 4 , standard standard standard standard Note 1) AS5000 is available as special. AS1000 is not applicable.

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH w/ IO-LINK, PRESSURE SWITCH, ISE1-6, N59, 75 lb

The basic parameter is not correct for the following condition: (Assignable value range) (1) Stroke (-) < Stroke (+) (2) W-Area 1 < W-Area2 (If both W-Area1 and W-Area2 is 0, the alarm will not be activated.) (3) Maximum pushing force < Maximum pushing force of The Parameter value is incorrect (01-049) System B RESET the electric actuator parameter input error

Motor output [W]/Size [mm] 750/80 Motor type AC servo motor200 VAC Encoder Absolute 22-bit encoderResolution4194304 p/rev Horizontal 135 Power consumption [W] *7 Vertical 150 Horizontal 15 Stnadby power consumption when operating [W] *8 Vertical 45 power [W] *9 Max.1100 Type *10 Non-magnetizing lock specifications 24 VDC Rated voltage [V] Power consumption at at20 [W] *11 Holding force [N

The basic parameter is not correct for the following condition: (Assignable value range) (1) Stroke (-) < Stroke (+) (2) W-Area 1 < W-Area2 (If both W-Area1 and W-Area2 is 0, the alarm will not be activated.) (3) Maximum pushing force < Maximum pushing force of The Parameter value is incorrect (01-049) System B RESET the electric actuator parameter input error

Inlet air temperature 35C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.5MPa Air flow 1200 l/min (ANR) Inlet air temperature 55C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.7MPa Air flow 350 l/min (ANR) Condition Condition A = 0.75 based on conditions q, w and e 1 B = 0.95 based on conditions q, w and e 1 C = 1.00 based on

7. * The seal kit includes 2 cushion seals, 1 rod seal, 1 piston seal, and 2 tube gaskets. 1.7-27 Series MBlQ Basic/(B) G G Cushion valve W V Port 2-Rc(PT)P MM D E MB Effective thread 2 X 4-J lC lB MA A K F N N S + Stroke H ZZ + Stroke (mm) Stroke range Width across flats Bore (mm) Effective thread length A D Ee11 F N G P MA S MB V J W K H ZZ MM lC lB 32 40 50 63 80 100 22 30 35 35 40 40

Body Size: 20, Model Type: A (Filter Regulator + Lubricator), Thread: N (NPT), Port Size: 02 (1/4), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: 3 (Lubricator w/Drain Cock), Bowl

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min;

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included)

Compact size (Width: 18 mm) Low power consumption: 1.8 W DC Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50C (No freezing.

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)