) ZS-33-JS () ZS-33-M () (3.02 ) ZS-33-MS () (3.03 ) ZS-33-R DIN 1 2 3 4 5 DIN F02(G/14)DIN -12No.PF-OMO0004CN-E (OUT) (IN) 1 2 2 INOUT DIN 1 2: LCD LED (UP) (SET) SET (DOWN) UP DOWN 3 ON/OFF (UP) 3 ON/OFF (DOWN) LED (OUT1)/ (SET) OUT1OUT2 OUT1ON OUT2ON 3 -13No.PF-OMO0004CN-E F.S. () 15 V F.S.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] 15 V 15 V 420 mA ON OFF ()
[Tips] The setting range of items is displayed on the Ten-key screen with the touch of the [V Lo] or [V Hi] key. A scaling must be specified to cause V Hi to be larger than V Lo (V Lo<V Hi). 5.3 Operation Screen HRZD Series 5-40 HRX-OM-M005 Chapter 5 Product Operation Procedure for setting analog output signal TYPE 1. Touch the [TYPE] key. The box appears flashing.
[How to JOG] a) Change the mode to Remote mode in the main window. b) From the main window select View (V), select the Teaching window and select the JOG tab. Refer to section "4.1 (1-1-2) View (V)" for how to display the Teaching window.
DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -21No.PS-OMU0008CN-D ZSE20C(F)/ISE20C(H)-S/-R () NPN 2 DC(+) Max.28 V80 mA 1 V R15 V OUT1 1 k S420 mA OUT2 12 V 300 24 V 600 DC(-) 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -22No.PS-OMU0008CN-D -V/-T () PNP 2 DC(+) Max.80 mA 1 V T15 V OUT1 1 k V420 mA OUT2
U 110 VAC V 200 VAC W 230 VAC Z Other voltages Note) For the class H type DIN terminal, use it in combination with the connector provided.
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V]x1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
Description Part number Note 3 4 7, 13 4 7, 13 6, 12 8 9 14 V band for replacement O-ring O-ring O-ring O-ring Quick plug Upper element holder Lower element holder Intermediate holder FQ-BA001 JIS B2401-1A-P85 JIS B2401-1A-P11 JIS B2401-4D-P85 JIS B2401-4D-P11 KT-FQ1-N KT-FQ1-N FKM KT-FQ1-V KT-FQ1-V AG-9S Stainless steel 303 Stainless steel 304 Stainless steel 304 Stainless steel 304 AG-9S
Description Part number Note 3 4 7, 13 4 7, 13 6, 12 8 9 14 V band for replacement O-ring O-ring O-ring O-ring Quick plug Upper element holder Lower element holder Intermediate holder FQ-BA001 JIS B2401-1A-P85 JIS B2401-1A-P11 JIS B2401-4D-P85 JIS B2401-4D-P11 KT-FQ1-N KT-FQ1-N FKM KT-FQ1-V KT-FQ1-V AG-9S Stainless steel 303 Stainless steel 304 Stainless steel 304 Stainless steel 304 AG-9S
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
The load doesnt work. < Auto switch operating range [mm] / Actuation operating speed [mm/s] -22No.D-S-OMJ0004-G Specifications D-M9B(E)(V)/D-M9N(E)(V)/D-M9P(E)(V) PLC: Programmable Logic Controller Switch part no.
Tie-rods Head cover assembly 30 Series MNB Selection of Models Step 1 Find the maximum load speed: V Precautions on Model Selection Caution Find the maximum load speed: V(mm/s) from the load movement time: t(s) and the movement distance: st(mm). 1.
[How to JOG] a) Change the mode to Remote mode in the main window. b) From the main window select View (V), select the Teaching window and select the JOG tab. Refer to section "4.1 (1-1-2) View (V)" for how to display the Teaching window.
collector output type-2 output Max. 80 mA Residual voltage 1 V or less T: Analog output 1 to 5 V Output impedance 1 k V: Analog output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Min. load impedance 50 -V/-T (Auto-shift input mode) With auto-shift switch output PNP open collector output type-2 output Max. 80 mA Residual voltage 1 V or less
IC circuit 5 V Yes (NPN equivalent) A93 A90 A54 A64 A59W A33 A34 A44 IC circuit 100 V 12 V 5 V, 12 V Grommet No Relay, PLC 100 V or less Yes 100 V, 200 V No 200 V or less 2-wire 24 V PLC Terminal conduit 12 V Relay, PLC Yes 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indication) Solid state auto switches marked with are produced upon receipt of order.
(3) Para protec a) Profaile View (V) 4.1 (1-1-2) View (V) Profaile b) Para protec Edit c) OK d) Download , e) 32 No.SFOD-OMT0011CN-A 4.3 PLC (: (1) 2 1-11-2 (1-1) a) View (V) 4.1 (1-1-2) View (V) b) Step No.Movement mode , Movement mode c) (0,0) (No.
Designation Content 1 SV24 V (PWR(V)) +24 V for valves 2 SV0 V (PWR(V)) 0 V for valves 3 SI24 V (PWR) +24 V for logic/sensors 4 SI0 V (PWR) 0 V for logic/sensors Fig. 2-4 Pin allocation of M12 4 pin plug A-coded connector Power-supply line for valves and power-supply line for logic/sensors operation are isolated. Be sure to supply power respectively.
Pin number Output (-) Output (+) Mark C on the unit Mark B at cable end Mark A at cable end 3 1 5 4 2 Output 2: Input (+) Output 2: Input (+) (1) Short circuit Short circuit 24 V 1: 24 V (Control and input) 24 V 1: 24 V (Control and input) 24 V 1: 24 V (Control and input) 0 V 0 V FE 4: Input (-) FE 4: Input (-) FE 4: Input (-) 24 V (control and input) 0 V (control and input) Analog input
(A/D ) ( ) 6 2030 20 80 mA (Er1,2) () ( (Er4,6,7,8) ) DC1224 V DC1224 V Er1,2) Er4,6,7,8) 7 (HHH) "HHH" "LLL" Er3) (LLL) (Er3) 7F.S. -27No.PS-OMG0001CN-H No. DC1224 V DC1224 V 8 DC(+) DC(-) DC1224 V DC1224 V DC(+) 9 DC(-) / / 10 ( ) 11 / 5m / 12 2030 20 -28No.PS-OMG0001CN-H No.
NPN(1 )(15 V) PFM7--CNPN(1 )(420 mA) PFM7--DDC(+) OUT1 DC(-) Max.28 V80 mA 1 V C15 V 1 k D420 mA 600 50 NPN(1 ) PFM7--GDC(+) OUT1 DC(-) Max.28 V80 mA 1 V ()30 ms -18No.PF-OMJ0005CN-I PNP(2 ) PFM7--BDC(+) OUT1 OUT2 DC(-) Max.80 mA 1.5 V PNP(1 )(15 V) PFM7--EPNP(1 )(420 mA) PFM7--FDC(+) OUT1 DC(-) Max.80 mA 1.5 V E15 V 1 k F420 mA 600 50 PNP(1 ) PFM7--HDC(+) OUT1 DC(-) Max.80 mA
) IC circuit A96 5 V Yes A33 A34 A44 A93 A90 A54 A59W 12 V 100 V Relay, PLC No IC circuit 5 V, 12 V 100 V or less 100 V, 200 V PLC Terminal conduit 2-wire 24 V 12 V Yes Relay, PLC 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indication) Solid state auto switches marked with are produced upon receipt of order.