Description Note 1 +15 V 1 2 1 2 5 2 Output signal 1 D-F8N 3 4 3 4 Display part 3 GND Socket connector A-coded (Normal key) Plug connector A-coded (Normal key) 4 Output signal 2 D-F8N DD1677
Test data available upon request. 40-140'F (5 -60"C) Non relieving type (Standard), 'Relieving type (NSR1101, NSR1, NSR3101, NSR3111, NSR4101, NSR4111) only applicabl icr N2 gas or air HolIY TO ORDER F luid / Diaphrag m M aterinl a I allvt size M5-10-32Nom(t!
RUGGED CONSTRUCTION-LOW COST OF OWNERSHIP f#jl"ffi;'"T$1iilJ,?"1H;i:T,ilil:;:,"".jHirir*H the use of off-the-shelf stainless steel cylinders. These cylinders include magnetic sensing rings for enhanced flexibility in sensing. Unparalleled rigidity is achieved by combining a 32mm ground rod and ZAYTRAN's proprietary ceramic bearing technology.
For the IR400-02/03/04□□: IR3000-02/03/04□□-A
For the IR401-02/03/04□□: IR3010-02/03/04□□-A
For the IR402-02/03/04□□: IR3020-02/03/04□□-A
For the IR412-02/03/04□□: IR3120-02/03/04□□ (IR-A series air operated regulators will be available at a later date.)
Note) Select option “H” when panel mounting the product.
Model: 41 (AC/Dual AC for IZTB40 and 42 Bars, and IZT43 Nozzles), Input, Output Specification: L (IO-Link), Power Supply Cable Length: None, Power Supply Cable Length (IO-Link): T (Entry Direction: Angled, Length: 5 m), Communication Cable Entry Direction/Length: T (Entry Direction: Angled, Length: 5 m), DIN Rail Mounting Bracket: W (DIN Rail Mounting Bracket Included)
Flow ranges (lpm): 0.5-4, 2-16, 5-40; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4 (flow range dependent); Temperature rating: 0-90°C; Output options: 1-5V, 4-20mA; Accuracy: ±5% F.S.; Repeatability: ±2% F.S.
Stations: 5 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: N9 (Dia.5/16 One-touch Fitting), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: None, Option 2: W (IP65 Protection Compatible)
Function: 5 (3 Position Pressure Center), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4), Thread: T (NPTF)
Function: 5 (3 Position Pressure Center), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 0 (Energized Open/N.C.), Option: A (BC6, Copper Body & Shading Coil, FPM Seal, Class B Coil), Port Size: 06 [3/4 (20A)], Thread: T (NPTF), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Flow ranges (lpm): 0.5-4, 2-16, 5-40; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4 (flow range dependent); Temperature rating: 0-90°C; Output options: 1-5V, 4-20mA; Accuracy: ±5% F.S.; Repeatability: ±2% F.S.
Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Function: 5 (3 Position Pressure Center), Piping: 20 (Body Ported/Individual Pilot EXH), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Thread: T (NPTF)
Function: 5 (3 Position Pressure Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 5 (3 Position Pressure Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200 VAC 4 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: CH1 20C/CH2 25C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200 VAC, u Piping length: Shortest 5 With the pressure control mode by inverter.
Stations: 5 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: N9 (Dia.5/16 One-touch Fitting), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: NSD (Name Plate, Built-in Silencer, Direct Exhaust from D Side)
Stations: 5 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: N9 (Dia.5/16 One-touch Fitting), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: SD (Built-in Silencer, Direct Exhaust from D Side), Option 2: W (IP65 Protection Compatible)
Stations: 5 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: N9 (Dia.5/16 One-touch Fitting), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: SD (Built-in Silencer, Direct Exhaust from D Side)