5% F.S. or less (0 to 50C, based on 25C)150 mA or less250 g1/8, 1/4Heater type3-digit, 7-segment LED?50 kPa to 0.5 MPa1.0 MPa0 to 999999 lSwitch outputSwitch outputAccumulated pulse outputIlluminates up when output is ON OUT1: Green; OUT2: Red1 sec. or lessHysteresis mode: Variable (can be set from 0), Window comparator mode Note 6) : 3-digit fixed12 to 24 VDC (ripple ?
5% F.S. or less (0 to 50C, based on 25C)150 mA or less250 g1/8, 1/4Heater type3-digit, 7-segment LED?50 kPa to 0.5 MPa1.0 MPa0 to 999999 lSwitch outputSwitch outputAccumulated pulse outputIlluminates up when output is ON OUT1: Green; OUT2: Red1 sec. or lessHysteresis mode: Variable (can be set from 0), Window comparator mode Note 6) : 3-digit fixed12 to 24 VDC (ripple ?
5% F.S. or less (0 to 50C, based on 25C)150 mA or less250 g1/8, 1/4Heater type3-digit, 7-segment LED?50 kPa to 0.5 MPa1.0 MPa0 to 999999 lSwitch outputSwitch outputAccumulated pulse outputIlluminates up when output is ON OUT1: Green; OUT2: Red1 sec. or lessHysteresis mode: Variable (can be set from 0), Window comparator mode Note 6) : 3-digit fixed12 to 24 VDC (ripple ?
5% F.S. or less (0 to 50C, based on 25C)150 mA or less250 g1/8, 1/4Heater type3-digit, 7-segment LED?
COUPLED, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, I5, 25MM CY3R CLEAN ROOM, 1.97376 lb, ModelBore size (mm)Port sizeLubricationStandard stroke (mm)Maximum manufacturable stroke (mm)Cushion RubberAir12-CY3R2525Rc1/8 NPT1/8 G1/8Non-lube100, 150, 200, 250, 300, 350,400, 450, 500, 600, 700, 8001300(Both sides)?
COUPLED, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, I5, 25MM CY3R CLEAN ROOM, 1.97376 lb, ModelBore size (mm)Port sizeLubricationStandard stroke (mm)Maximum manufacturable stroke (mm)Cushion RubberAir12-CY3R2525Rc1/8 NPT1/8 G1/8Non-lube100, 150, 200, 250, 300, 350,400, 450, 500, 600, 700, 8001300(Both sides)?
10% or less)150 mA or lessIP650 to 50C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?
10 to 50C35 to 85%RH (with no condensation)1500 VAC for 1 min. between external terminals and FG10 M or more (500 VDC) between external terminals and FG10 to 150 Hz with a 0.35 mm amplitude or 49 m/s2 in each X, Y, Z direction for 2 hrs (De-energized)98 m/s2 in each X, Y, Z direction, 3 times (De-energized)CE marking, UL (CSA)120 g
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
/s2] Note 6)Actuation typeGuide typeOperating temp. rangeOperating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 7)Standby power consumption when operating [W] Note 8)Momentary max. power consumption [W] Note 9)Controller weightType Note 10)Holding force lbf [N]Power consumption [W] Note 11)HorizontalVerticalLEY25A30, 50, 100, 150
/s2] Note 6)Actuation typeGuide typeOperating temp. rangeOperating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 7)Standby power consumption when operating [W] Note 8)Momentary max. power consumption [W] Note 9)Controller weightType Note 10)Holding force lbf [N]Power consumption [W] Note 11)HorizontalVerticalLEY25A30, 50, 100, 150
The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?