Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 5 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting), Mounting: Direct Mounting, DIN Rail Option: DIN Rail Mounting, w
Type: 11S (Bottom Ported), SI Unit Specification: DA (EtherCAT - 32 Outputs - Connector M12), SI Unit Output Polarity: N (Negative Common), Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit Specification: DA (EtherCAT, IO-Link unit), SI Unit Output Polarity, End Plate: 4 (SI Unit Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 16 Stations, P,E Port, SUP/EXH Block: J (B Side, 2 to 24 Stations, External Pilot), A,B Port Size: C8 (ø8 One-touch Fitting, Straight, Metric)
Model: 10S6 (Side Ported), SI Unit Specification: DA (EtherCAT, IO-Link unit), SI Unit Output Polarity, End Plate: 4 (SI Unit Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 13 Stations, P,E Port, SUP/EXH Block: J (B Side, 2 to 24 Stations, External Pilot), A,B Port Size: C8 (ø8 One-touch Fitting, Straight, Metric)
Model: 10S6 (Side Ported), SI Unit Specification: DA (EtherCAT, IO-Link unit), SI Unit Output Polarity, End Plate: 4 (SI Unit Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 12 Stations, P,E Port, SUP/EXH Block: J (B Side, 2 to 24 Stations, External Pilot), A,B Port Size: C8 (ø8 One-touch Fitting, Straight, Metric)
Stations: 6 Stations (Note: 2 Stations are Required for Serial Unit Mounting), Port Size: C8 (ø8 One-touch Fitting), Mounting Base: S (U Side), Kit Type: Q (DeviceNetâ„¢, 16 Output Points), Option 1: None, Option 2: W (Dust Poof IP65 Rated)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate
Model: 10S6 (Side Ported), SI Unit: DA (EtherCAT, IO-Link unit), SI Unit Common, End Plate: 2 (Positive Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 15 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: C8 (ø8 One-touch Fitting), Mounting: AA (Direct Mounting, Name Plate w/Station Number)
Model: 10S6 (Side Ported), SI Unit: DA (EtherCAT, IO-Link unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: 6 Stations, Valve Stations: 15 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: C8 (ø8 One-touch Fitting), Mounting: AA (Direct Mounting, Name Plate w/Station Number)
Model: 10S6 (Side Ported), SI Unit: EB (EtherNet/IPâ„¢, IO-Link Unit), SI Unit Common, End Plate: 2 (Positive Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 6 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A, B Port Size: C8 (ø8 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: KA (IO-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 4 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: EB [EtherNet/IPâ„¢ IO-Link Unit], SI Unit Common, End Plate: 7 (Power Supply w/M12 Connector, PNP, IN/OUT Pin Arrangement 1), I/O Unit Stations: None, Valve Stations: 16 Stations, P,E Port, SUP/EXH Assembly: F (Internal Pilot, Built-in Silencer; Both Sides, 2 to 24 Stations), A,B Port Size: C8 (ø8 One-touch Fitting
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None)
Type: 10S (Side Ported), SI Unit Specification: DA (EtherCAT - 32 Outputs - Connector M12), SI Unit Output Polarity: N (Negative Common), Valve Stations: 3 Stations, P, E Port Location: U (U Side), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: C8 (ø8 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 0 (w/o DIN Rail, w/Bracket)
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 4 (220VAC 50/60HZ), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), Port Size: C8 (Body Ported ø8 One-touch Fitting)
Series: 5 (SY5000), Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot Type: Internal Pilot, Coil Specification: Standard, Rated Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: D (Push-turn Locking Slotted Style), A,B Port Thread: C8 (Body Ported ø8
Stations: 8 Stations, Port Size: C8 (ø8 One-touch Fitting), S Kit: SKA (IO-Link - 32 Outputs - Connector M12), SI Unit Polarity: N (Negative Common), Option 1: None, DIN Rail Length: Standard (or None if w/o DIN Rail), Option 2: S (Built-in Silencer, Direct Exhaust)