The MXY is a long stroke precision slide table, light weight in design that provides constant rigidity throughout the entire stroke, up to 400 mm. It is integrated with hardened stainless steel guides and rails to isolate the load bearing from the movement of the piston rod and seals.
Double acting, single rod; Bore size (mm): 40, 50, 63; Standard stroke (mm): 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500; Rc, NPT or G port threads; Clean series
Bore sizes: 25, 32 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke length: 1300 mm (25, 32, 40, 50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Body sizes: 40 (100W), 63 (200W), 100 (750W); Maximum workload: 55 kg (size 40), 85 kg (size 63), or 400 kg (size 100); Maximum speed: 2300 mm/s (size, lead, and stroke dependent); Maximum stroke: 1500 mm; Positioning repeatability: ±0.01mm (size and lead dependent); Motor encoders: incremental 17-bit; absolute 18- or 22-bit
Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Series 25A-CY3B is compatible with secondary battery applications
Double acting, guided actuator ; High temperature(XB6)Bore sizes(mm): 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 ; Slide bearing type ; Standard stroke range (mm): 10 to 400 ; Port threads: M (12 to 25 bore), Rc, NPT or G (32 to 100 bore) ; High temperature option (XB6) ambient range -10 to 150°
Manufacturers include Mitsubishi, Yaskawa, Sanyo Denki, Omron and Panasonic Body sizes: 40 (100W), 63 (200W), 100 (750W); Maximum workload: 55 kg (size 40), 85 kg (size 63), or 400 kg (size 100); Maximum speed: 2300 mm/s (size, lead, and stroke dependent); Maximum acceleration:: 20,000 mm/s² (40, 63) 9,800 mm/s² (100); Positioning repeatability: ±0.01mm (size and lead dependent); Stroke range
Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz); 200~230; STO (Safe Torque Off) safety function available; Display and settings buttons for direct input and status monitoring; Compliant with SEMI F47 Standard; SigmaWin+ Configuration software required (download available separately)
Two models available: ZVB40 (single ionizer) = 210 W x 297 D x 351 H (mm), ZVB40 (double ionizer) = 400 W x 384 D x 390 H (mm); Static electricity removal performed by an IZN10 nozzle iionizer; Static neutralization in 1 second or less; Ion balance is ±10V; Accessories include exhaust hose, dust bag, and AC adapter
Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications
Power supplies are available in 200 and 400 VAC 3-phase, and function in both 50 and 60 Hz environments for global compatibility. Alarms report on a variety of circuit and equipment conditions to preserve optimal operation.
Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz): 100~120V no longer available; 200~230 (LECSS-S); 200~240 (LECSS-T); Display and settings buttons for direct input and status monitoring; LEC-MRC2 Configuration software required (sold separately); C-UL-US listed (LECSS2-T only)
Positioning table points: 255; Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz): 200~230; Display and setting buttons for direct input and status monitoring; LEC-MRC2 Configuration software required (sold separately); C-UL-US listed (LECSC2-T only)
Body size: 25; Maximum work load: 9 kg (horizontal), 4 kg (vertical); Maximum pushing force: 180 N; Maximum speed: 400 mm/s; Strokes: 50, 100, 150; Positioning repeatability: ±0.05mm
Body size: 25; Maximum work load: 5 kg (horizontal or vertical); Maximum pushing force: 180 N; Maximum speed: 400 mm/s; Strokes: 30, 50, 75, 100, 125, 150mm; Positioning repeatability: ±0.05mm
Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications
EtherNet/IP™: AOI available for Studio 5000 Logix Designer; EtherCAT®: IEC61158 Type 12 CAN application protocol over EtherCAT® (CoE) and IEC61800-7CiA402 drive profile; PROFINET: includes PROFINET IO Real Time (RT); Compatible motors (W): 100/200/400/750; Power supply voltage (VAC, 50/60Hz): 200~240; Display and settings buttons for direct input and status monitoring; LEC-MRC2 Configuration
Body size: 8, 16, 25; Strokes: 50, 75, 100 or 150mm; Maximum work load: 12 kg (horizontal, 20 kg (vertical)); Maximum pushing force: 420 N; Maximum speed: 400 mm/s; Positioning repeatability: ±0.01mm
Bore sizes: 16, 25, 40, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15 ~ 0.20 MPa (22 ~ 29 psi); Speed: 80~1000 mm/sec (w/o stroke adjustment bolt), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3M is compatible with secondary battery applications
Body size: 16, 25; Strokes: 50, 100, 150mm; Maximum work load: 12 kg (horizontal), 20 kg (vertical); Maximum pushing force: 385 N; Maximum speed: 400 mm/s; Positioning repeatability: ±0.01mm; Encoder resolution: 17-bit (S motors), 22-bit (T motors), 20-bit (V motors)