SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2F80-75DZ-M9PWSDPC"

Bore Size: 10mm, Stroke: 60mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in Magnet), Cushion Type: A (Air Cushion), Bore Size: 25mm, Stroke: 25mm, Thread: Male Rod End, Rod End Bracket: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Bore Size: 16mm, Stroke: 30mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 106 (1 1/16"), Stroke: 0100 (1"), Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in Magnet), Mounting: B (Basic), Bore: 50mm, Port Thread: TF (G), Stroke: 250mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: No Bracket, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, LONG STK *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, RE, 80MM CQ2 DBL-ACT AUTO-SW, 14.73089 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, RE, 80MM CQ2 DBL-ACT AUTO-SW, 8.87360 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, LONG STK, ACTUATOR, CQ2 COMPACT CYLINDER, RE, 80MM CQ2 DBL-ACT AUTO-SW, 9.86568 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, LONG STK *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, RE, 80MM CQ2 DBL-ACT AUTO-SW, 10.80265 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, LONG STK, ACTUATOR, CQ2 COMPACT CYLINDER, RE, 80MM CQ2 DBL-ACT AUTO-SW, 11.76717 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, LONG STK, ACTUATOR, CQ2 COMPACT CYLINDER, RE, 80MM CQ2 DBL-ACT AUTO-SW, 11.13334 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, LONG STK *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, RE, 80MM CQ2 DBL-ACT AUTO-SW, 13.69315 lb

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,