SMC Corporation of America
Elite Part Number Search
Search Results "53-SY5A20-L6-01N"

Bore size (mm) A B A + B + 90 B DA DB DL DU DC DX DE DO DR DT DS DH Z DDH10(Hole) 32 40 50 63 80 100 6.6 54 42 32 22 44 14 62 9 15 7 33 224 10 +0.058 0 10 32, 40 160 25 45 MB-B03 6.6 63 42 32 22 44 14 62 9 15 7 33 235 10 +0.058 0 10 9 75 53 43 30 60 20 81 10.5 18 8 45 271 11.5 +0.070 0 14 50, 63 190 40 60 MB-B05 9 90 53 43 30 60 20 81 10.5 18 8 45 285 +0.070 0 11.5 14 +0.084 0 11 102 73 64

Weight reduced by 53% at the maximum Overall length (Z + Stroke) Overall Length (Z) Weight (mm) (kg) Series MY3A MY3B MY1B Series MY3A MY3B MY1B 63 63 40 40 25 25 16 16 320 8.26 240 2.95 150 0.99 110 0.34 356 8.99 276 3.08 178 1.09 122 0.35 460 14.5 340 4.41 220 1.57 160 0.73 At a 100 mm stroke Series Variations Positioning cushion mechanism The uniquely designed piston shape enables reduction

230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3.5 16.5 14 13 20 6 F 6 6 5 Piping port 2-M4 x 0.7 13.5 Bottom hole diameter 3.3 2-M3 x 0.5 17 0.05 (Plug: M-3P) Mounting base side B D M Stroke: S 1 5 J Z 2.4 Piping port 2-M3 x 0.5 (mm) Z S M J H F Model MXPJ6-5 44 5 37 27 38 25 MXPJ6-10 59 10 47 42 53

70 70 90 90 8.4 13 12.5 12.5 13 13 5.4 6.5 8.5 8.5 11 11 22 23 26 25 35 35 27 35 52 52 66 66 30 41 50 50 70 70 20 26.7 35.5 35.5 45 47.5 25 35 40 40 30 30 30 38.4 38.4 20 26.7 35.5 35.5 45 47.5 9.8 14 18 20 24 24 91.4 121.9 153.9 155.9 226.9 240.9 40 53 70 75 90 95 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 1070 A

117 29 29.5 M38 x 1.5 29.5 1/4, 3/8 ARP40(K) 1 1/4 70 148 41 34 M42 x 1.5 34 1/4, 3/8, 1/2 Optional specifications Digital pressure switch Round type pressure gauge Note 3) Bracket mount dimension Panel mount Model Z ARP20(K) H J H J M N Q R S T U V W Y 27.8 1021 1021 1021 44 40 69 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 ARP30(K) 27.8 44 41 70 41 40 44 6.5 8 53 2.3 31 38.5 19 7 ARP40(K) 27.8

2 2 2 8 0.5 0.5 P=11 10 M5: M5 thread 2n-M5 4(A), 2(B) port 4 L2 35 L1 38 42 M plug connector (M) Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Stations 1 2 3 4 5 n D side U side Direct manual override (Non-locking) 24 15 43 L plug connector (L) n: Stations Dimensions n L 11 12 13 14 15 16 17 18 19 20 28 20 39 31 50 42 61 53

55 57 59 53 55 57 59 94 95 14.5 AS-FE 14.3 1 8 14.2 36.1 31.1 30.5 25.5 15.5 18.5 21 14.5 15.5 18.5 21 17 18.5 21 22 17 18.5 21 22 21 22 12 KE 15.0 AS-FG 17.2 17 1 4 18.5 39.4 34.4 32.0 26.6 AS-FP 19 AS-FM 1 4 45.9 40.9 38.1 33.1 23.0 19 20.3 AS-D AS-T 19.4 45.0 40.0 37.6 32.6 19 3 8 23.0 ASP 1 2 28.6 24 22.4 54.6 47.1 44.5 37.0 ASN Note 1) Reference dimensions Note 2) Reference dimensions

104.1 14 26.7 30 35 26.7 41 35 23 6.5 13 53 2.3 30 AFJ40 1/4, 3/8, 1/2 70 136.1 18 35.4 38.4 40 35.4 50 52 26 8.5 12.5 70 2.3 35 785 AFJ Series Specific Product Precautions 1 Be sure to read this before handling the products.

D OUT OUT IN E 2 x A (Port size) F SMC J C H 4 x K Bracket mounting thread A C D E F G H J K Model AF30-02 to 03-X2230 AF40-02 to 04-X2230 AF40-06-X2230 AF50-06 to 10-X2230 AF60-10-X2230 57 118 Rc 1/4, 3/8 Rc 1/4, 3/8, 1/2 Rc 3/4 Rc 3/4, 1 Rc 1 M4 x 0.7 x 0.5 M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 44 35 53 14 53 258 245 169 165 78 73 60 60 63 59 47 47 73 73 95 90 70 70 24 24 20 18 95 90 75 70 1056

A C D E F G H B Composition of assembly Set nut (1349172) AP100 ARM2500 136314 30 34 70 5.4 15.4 55 2.3 M33 x 1.5 Bracket (B220) Inlet pressure (MPa) Set nut (131532) ARM3000 136414 75.5 8 41 40 6.5 53 2.3 M42 x 1.5 Bracket (B320) Note) Tighten the set nut securely and fix it.

Wiring top entry) Digital pressure switch (Electrical entry: Wiring bottom entry) Square embedded type pressure gauge Option Round type pressure gauge J J J J H Dimensions Center of piping H H Center of piping Center of piping H Center of piping Standard specifications Model P1 P2 A B Note 1) C D F J K ARP20(K) ARP30(K) ARP40(K) 28.5 Note 2) 1/8 40 98 27 28.5 M28 x 1 2 1/8, 1/4 29.5 1/8 53

Wiring top entry) Digital pressure switch (Electrical entry: Wiring bottom entry) Square embedded type pressure gauge Option Round type pressure gauge J J J J H Dimensions Center of piping H H Center of piping Center of piping H Center of piping Standard specifications Model P1 P2 A B Note 1) C D F J K ARP20(K) ARP30(K) ARP40(K) 2 Note 2) 40 1/8 98 27 28.5 M28 x 1 28.5 1/8, 1/4 2.5 1/8 53

M38 x 1.5 29.5 2.5 1/4, 3/8, 1/2 1/4 70 148 41 34 M42 x 1.5 34 1 Optional specifications Square embedded type pressure gauge Digital pressure switch Round type pressure gauge Note 3) Bracket mount dimension Panel mount Model Z ARP20(K) ARP30(K) ARP40(K) H J H J H J M N Q R S T U V W Y l28 l27.8 37.5 29.5 40 66 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 l28 l27.8 37.5 30.5 41 67 41 40 44 6.5 8 53

Optional specifications Round type pressure Round type pressure gauge gauge (with color zone) Bracket mount Panel mount P1 P2 A B C D F J H J H J M N Q R S T U V W Y Z AR10-A M5 x 0.8 1/16 25 47.4 11 12.5 M18 x 1 12.5 26 26 25 28 30 4.5 6.5 40 2 18 18.5 AR20-A 1/8, 1/4 1/8 40 67.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 43.9 5.4 15.4 55 2.3 27.3 36.5 17.5 6 AR25-A 1/4, 3/8 1/8 53

Terminal Setting() 47 50 52 53 53 -1No.EX-OML0010CN-C (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361:

No.PF-OMO0004CN-E // PFMB7201 2 10 13 14 16 16 19 21 [] 25 OU1OUT2 {3 ] 26 28 [] 28 28 F0 29 F1 OUT1 31 F2 OUT2 39 F3 44 F10 45 F13 46 F20 47 F22 48 F30 49 F31 50 F80 OFF 51 F81 52 F90 53 F98 55 F99 56 57 61 62 64 65 65 68 71 -1No.PF-OMO0004CN-E (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic

No.PF-OMP0001CN-F // PFMB7501 PFMB7102 PFMB7202 2 10 11 12 14 14 16 17 [] 21 OU1OUT2 {3 ] 22 22 [] 24 25 F0 26 F1 OUT1 28 F2 OUT2 36 F3 41 F10 42 F13 43 F20 44 F22 45 F30 46 F31 47 F80 OFF 48 F81 49 F90 50 F98 52 F99 53 54 58 59 61 62 62 65 67 -1No.PF-OMP0001CN-F (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems

No.PF-OMN0011CN-C / / PF3W3## SMC 2 9 12 13 15 15 16 21 23 23 F0 25 F1 OUT1 26 F2 OUT2 34 F3 40 F10 41 F20 45 F22 46 F30 48 F80 49 F81 50 F82 51 F90 52 F96 53 F97 54 F98 57 F99 58 59 62 63 66 66 69 71 -1No.PF-OMN0011CN-C (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules

4.6 9.5 14 56 38 2.5 depth 8.5 2.6 Approx. 70g LFE38(Z) 62 53 4.6 3.5 20 68 43 2.5 depth 8.5 2.6 Approx. 70g NOTE) If you are installing directly, choose the self tapping screw in depth is to 8mm.

Table 5.18-4 List of set value Set value Explanation Initial value (Default setting) Not reset Compressor accumulated operating time is reset HRS Series 5.18 Accumulated time reset function 5-53 HRX-OM-M090 Chapter 5 Display and setting of various functions 5.19 Communication function 5.19.1 Communication function The product can have contact input/output and serial communication.