Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Please contact us for the latest version.sales@ocaire.com, P R ASSY CHKDB40-DCG2227G-75, OTHERS, 40MM CH PART, .00000 lb
Zoom Choose from 200, 150, 100, 75, 50, 25, or 10% zoom factor 5.4 Insert Icons into Vacant Terminals Input S and Output S icons will be inserted into any vacant Input or Output Terminals, respectively. Insert New Object Insert a Display, OLE, or le into the System Sketch Window. Links... Edit links between the SMC VLS le and other documents.
Display the error code on LCD. 3 1/2 digits (5 mm-size numerals) Overcurrent, Overpressure, Data error Pressure during 0 clear 0 to 60C (No dewing) 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Between external terminals and housing 1000 VAC, 50/60 Hz for 1 min.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2003 SMC CORPORATION All Rights Reserved 1st printing August, 2003 D-YGA P-120 (YG) All specifications in this catalog are subject to change without notice. Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.
Ol5 (M5) o.z 0r5 -oz -Body ported {wjth bracket} NVKF332Y {Low watlaqe: 2WDC) NVKF332V {Vacuum) l Ton-100 PSI (-100 KPa-o.7 MPa) NVKF332W tLow wattaoe + Vacuuml 0.181 lbs (80 s0 NVKF333 0-100 PSI {0-0.7 MPa) NVKF333Y ilow waltaqe: 2WDC) NVKF333V (Vacuum) 1 Torr"100 PSI (-100 KPa-0.7 MPa) NVKF333W ilow wattaoe + Vacuuml 2 position srngre solenoid (for maniiold) 0r5 NVKF334 0 ' 1 0 0 P S I
This is a legacy product, and replaced byIDG30A-03B-P, AIR DRYER, MEMBRANE(300/75)-20, OTHERS, IDG MEMBRANE AIR DRYER, IDG 3/8 MEMBRANE AIR DRYER, 2.90176 lb, ModelRange of operating conditionsStandard perfor- manceStandard performance conditionsDew point indicator purge air flow ratePort size (Nominal size B)Weight (kg) (With bracket)FluidInlet air pressure (MPa)Inlet air temperature
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 350mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 150mm, Option: K [Heat Resistant Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 600mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 800mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)