235.5 225 201 17 260.5 250 233 13.5 148 137.5 121 13.5 198 187.5 169 14.5 248 237.5 217 15.5 Stations SS5X5-45PDBC4 C6 C8 Stations L1 L2 L3 L4 2 148 137.5 123 12.5 3 4 5 6 7 8 9 10 185.5 175 155 15 210.5 200 187 11.5 235.5 225 203 16 260.5 250 235 12.5 285.5 275 251 17 198 187.5 171 13.5 248 237.5 219 14.5 173 162.5 139 17 Stations L1 L2 L3 L4 11 298 287.5 267 15.5 13 14 15 16 12 310.5 300
For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500
Dimensions Formulae L1 = 16n + 53 L2 = 16n + 87 n: Stations (max. 16 stations) L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 L2 (L3) (L4) 85 119 150 160.5 101 135 162.5 173 117 151 175 185.5 133 167 187.5 198 149 183 212.5 223 165 199 225 235.5 181 215 237.5 248 197 231 262.5 273 213 247 275 285.5 229 263 287.5 298 245 279 300 310.5 261 295 325 335.5 277 311 337.5 348 293 327 350 360.5 309
SMC PRESSURE SWITCH PD PV 57 1 67 1 32.4 109 Approx. 300 Ejector RESET SET Supply valve Release valve V 21.2 Manual override Suction filter 1 2-4.6 (mounting hole) 1 5.6 1 8 1 10.2 123 1 4.6 1 8 SOL. c SOL. a Silencer SOL. b Interface A Light Suction filter Manual override Interface B Digital vacuum pressure switch M5 port PE (pilot valve exhaust port) M5 port PD (vacuum breaking pressure
needle 6 One-touch fitting Port V 67 35.3 Supply port 6 One-touch fitting Port P1 ZYY35LZ-10S1 (specifications without vacuum switch) End plate (P44027A) Manual override 3 31 51.4 In case of locking type, turn after pushing in. 13.5 5.25 16.5 55.5 Manual override In case of locking type, turn after pushing in. 117.1 Approx. 300 (Lead wire length) 10 Series ZYY/ZYX Ejector Valve Dimensions
This is a legacy product, and replaced byPSE201A-A4C PSE200/300/530-560. CONTROLLER, PRESSURE SENSOR. INSTRUMENTATION. PSE200/300/530-560 OTHER SIZE. 1.08881 lb. 1X.
Set the total current capacity to 300 mA. 300 mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be configured by one. 11.
Item Setting value, setting Default AXIS AXIS AXIS AXIS range value 1 2 3 4 0:mm 3 0 150 300 450 1:inch 2:degree 3:PLS Pr.1 Unit setting Movement Pr.2 Pulse number amount per 1 to 20 (Note 1) 20 2 3 152 153 302 303 452 453 pulse per rotation(AP) (Unit: PLS) Pr.3 Moving amount The setting value range differs according to the "Pr.1 Unit setting". 20 4 5 154 155 304 305 454 455 per rotation
When set to the factory setting (Pn600 = 0), the DRIVERs built-in option has been used. 27 - When the external Regenerative resistors for power are used at the rated load ratio, the resistor temperature increases to between 200 C and 300 C. The resistors must be used at or below the rated values. Check with the manufacturer for the resistors load characteristics.
When set to the factory setting (Pn600 = 0), the DRIVERs built-in option has been used. 26 - When the external Regenerative resistors for power are used at the rated load ratio, the resistor temperature increases to between 200 C and 300 C. The resistors must be used at or below the rated values. Check with the manufacturer for the resistors load characteristics.
Assy 2V Assy Assy 18 - No.ZB-OM00301 O Assy V Assy Assy V Assy Assy 19 - No.ZB-OM00301 1TK1-123 2 3 1VKJ 2 3 1 0.1 2 0.1 3 0.15 -0.2 2 20 - No.ZB-OM00301 () ( ) ONOFF () 0.1Nm 1 ON 0 ) () () 1 (PA) 0 (AR) () 21 - No.ZB-OM00301 AXT661-12 0.2~0.33mm 2 (1.7mm) ) DXT170-71-1 3.2~3.7mm (DXT170-75-1) 2 0.2~0.33mm (1.7mm) (ACB (1mm) 22 - No.ZB-OM00301 N.C. 300
IDF11E Rc3/4 IDF Series 6-3 6 3 IDX-OM-W011 6 IDF15E1 mm 603 41 54 300 16 C R 1 C R 1 87 578 [AC200V] [AC200V] 396 0.8m (10, (:10, :0.8m) 43 15 270 13 4x 380 101 258 314 [AC100V] (:1.9m [AC100V] [AC200V] [AC200V] ( 17) (17) 1.9m 6-4 IDF1E3E ILS 3 PTC (50/60Hz) AC100/100,110V 2 1 (BK) (WH) 1 SYMBOL DESCRIPTION M 2 1 S 5 CM 2 (GR) CM COMPRESSOR MOTOR PC OLR C (SY) (50/60Hz)
Documents 7.1 Specifications Models Specification IDFA60-23 IDFA70-23 IDFA80-23 IDFA90-23 Fluid Compressed air Operati Inlet air temperature oC 5 to 65 ng range Inlet air pressure MPa 0.15 to 1.0 (Note 3) (Note 1) Ambient temperature (Humidity) oC 2 to 45 (Relative humidity 85 % or less) Outlet air 3 oC 204 312 552 810 pressure dew Standard condition (ANR) (Note 2) point Outlet air 7 oC 300
Series 6 1 IDX-OM-W017 6 6-2 GWP (GWP) Regulation (EU) No 517/2014 IPCC AR4) R134a 1,430 1,430 R404A 3,922 3,920 R407C 1,774 1,770 R410A 2,088 2,090 (1) (2) IDFA Series 6-2 GWP 6 2 IDX-OM-W017 6 6-3 mm IDFA4E15E1 A B C D E F G H J K L M N P Q IDFA3E Rc3/8 226 410 473 67 125 304 33 73 31 36 154 21 330 231 15 IDFA4E Rc1/2 453 13 498 283 275 IDFA6E 455 275 Rc3/4 15 485 568 355 300
] IDFB11E [485] [568] [355] IDFB15E 1 11.8 23.7 22.8 1.6 2.1 16.6 3.4 10.2 1.7 0.6 10.6 4.0 15 12.4 0.6 [300] [603] [578] [41] [54] [396] [87] [258] [43] [15] [270] [101] [380] [314] [16] 6-3 6 4 IDFB Series IDX-OM-W020 6 6-4 IDFB3E 1 2 CM P FM1,2 1 2 PE OLR TB PTC PTC PE 1 2 ILS PRS S TB P CM FM P IDFB4E / 6E / 8E S R GFCI CM FM1,2 OLR V PTC PTC ILS PRS TB
(P2) () 3) 4) 5) 23 5 No.VEX-OMY0001 VEX3 3 / DC () 5 20N 1) 2) 1 ()ISO VG32 2 ISO VG32 ,(SDS) 6 No.VEX-OMY0001 VEX3 3 / () 30 ( ) , 1 VG32 2 ()ISO VG32 7 No.VEX-OMY0001 VEX3 VEX3 12,22,32,42 ,300mm DXT170-80-A1) 2) Lmm 2 300 6 600 1 (2 ) AC100V 10 1000 2 (2 ) AC200V 15 1500 3 (2 ) AC 20 2000 DC L 4 :+ :DC 25 2500 DXT170-71-1 30 3000 0.20.33mm ( 1.7mm) DC : M 3.23.7mm
In Administrator mode, a timeout occurs after 300 seconds of inactivity and the application returns to Monitor mode. A timeout countdown is displayed to the right of the "Administrator mode" label. The NFC communication is not accessed all the time. Therefore, always update the content displayed on the screen by clicking the "Refresh" button when reading the parameters.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125, 140, 160 , Standard stroke (mm): 10 through 300 , Through hole mount, Auto switch capable, Compact Cylinder, NCQ2-Z, COMPACT CYLINDER, 300 lb
Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size (mm): 125, 140, 160, 180, 200, Standard stroke (mm): 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, Compact Cylinder, NCQ2-Z, COMPACT CYLINDER, 300 lb