Control Method: E (Meter-out, Gray), Stud Position: A (Right Side), Tube Diameter: 03 (ø5/32"), Thread Type: N (NPT), Port Size: 01 (1/8)
Control Method: E (Meter-out, Gray), Stud Position: B (Left Side), Tube Diameter: 03 (ø5/32"), Thread Type: N (NPT), Port Size: 01 (1/8)
Control Method: S (Meter-in, Light Blue), Stud Position: A (Right Side), Tube Diameter: 03 (ø5/32"), Thread Type: N (NPT), Port Size: 01 (1/8)
Control Method: S (Meter-in, Light Blue), Stud Position: A (Right Side), Tube Diameter: 03 (ø5/32"), Thread Type: N (NPT), Port Size: 01 (1/8), Sealing Method: S (w/Sealant)
Control Method: S (Meter-in, Light Blue), Stud Position: B (Left Side), Tube Diameter: 03 (ø5/32"), Thread Type: N (NPT), Port Size: 01 (1/8)
Control Method: S (Meter-in, Light Blue), Stud Position: B (Left Side), Tube Diameter: 03 (ø5/32"), Thread Type: N (NPT), Port Size: 01 (1/8), Sealing Method: S (w/Sealant)
.: 03 (ø5/32"), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: N (NPT), Size: 01 (1/8)
.: 03 (ø5/32"), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: N (NPT), Size: 01 (1/8)
.: 03 (ø5/32"), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: N (NPT), Size: 01 (1/8), Seal Method: S (w/Sealant)
.: 03 (ø5/32"), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: N (NPT), Size: 01 (1/8), Seal Method: S (w/Sealant)
Indicator: S, Control Method: S (Meter-in), Stud Position: A (Right Side), Tube Diameter: 03 (ø5/32"), Thread: N (NPT), Port Size: 01 (1/8), Seal Method: S (w/Sealant)
Indicator: S, Control Method: S (Meter-in), Stud Position: B (Left Side), Tube Diameter: 03 (ø5/32"), Thread: N (NPT), Port Size: 01 (1/8), Seal Method: S (w/Sealant)
Indicator: S, Control Range: M (1 to 50mm/s), Control Method: S (Meter-in), Stud Position: A (Right Side), Tube Diameter: 03 (ø5/32"), Thread: N (NPT), Port Size: 01 (1/8), Seal Method: S (w/Sealant)
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL W/FITTING *LQA, AIRLINE EQUIPMENT, AS***F 1/2INCHSTANDARD (NPT), .21958 lb
Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 3-STA, VACUUM EJECTOR, 205 lb
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
MGP Auto switch model 20 25 32 40 1000 Holding force (N) D-B5, B6 D-G5, K5 D-C7, C8 D-H7 MGQ BA-01 BA-02 BA-32 BA-04 40 BMA2-020 BMA2-025 BMA2-032 BMA2-040 MGG 500 32 25 Stainless steel mounting bolt set The set of stainless steel mounting screws described below is available and can be used depending on the operating environment.
02 03 04 06 10 Type 1 8 ASS100/110 ASS300/310 ASS300/310 ASS500 ASS500/600 ASS600 ASR PAT.PEND 1 4 00 10 Meter-out control type Meter-in control type Meter-in type is available only for ASS110 and ASS310. 8 3 ASF 1 2 3 4 1 JIS Symbol Thread type Nil N F Rc NPT G Meter-out control Meter-in control Caution Be sure to read before handling.