To distinguish from the D type DIN connector, N is listed at the end of voltage symbol. Dimensions are completely the same as D type DIN connector. 18 Safety Standard ISO13849-1 Certified * 3 Port Solenoid Valve/Residual Pressure Release * Refer to page 2 for compliant products.

When mounting the product, please do not block the exhaust port at the center of the body as this may cause performance issues.

A B L L2 MM R1 R2 U L2 MM L1 NDd9 3 NDH10 3 NX Part no.

5 to 60C (with no freezing)1.5 MPa1.0 MPa0.05 to 0.85 MPaSet pressure + 0.05 MPa Note 3) [at relief flow rate of 0.1 l/min (ANR)]5 ?mPolycarbonateStandardRelieving type0.55

Add the x symbol at the beginning of parl numbers lor electro-pneumalic regulators, etc. to be mounted on the base. Note 1) Electro-pneumalic regu ators are counted slarling from slation 1 on the left side with the OUT porls in lrontNote 2) The port size tor mounted electro-pneumalic rcgulators is Rc1/8 (1w1000), Rc1/4 (1TV2000) only.

T M5 type H (width across flats) Applicable tubing O.D. d A A4 D1 L3 D2 M1 L1 T L2 Model Weight (g) Note 2) Tubing O.D. d T H D1 D2 L1 L2 L3 M1 L4 Max.

L6 A Note) Model Applicable tubing O.D. d H Weight (g) D L1 L2 L3 L4 L5 M T Min. Max. Min.

Installation at indoor site (for air cooled type) 1. For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2.

Installation at indoor site 1. For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2.

The product operation at the time of alarm AL21 can be selected. This function is set to [ ] (stop) at the time of alarm by default.

The circulating fluid may boil or back-flow which causes overflow from the tank when the product is at a halt, if disregarded.

Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude For the product operation at an altitude of 1800 meters, the cooling capacity at an altitude of 1800 meters = the cooling capacity at an altitude of 1000 meter x 0.8. 2. Cooling Altitude [m] 1. Max. ambient capacity temp.

Blinks during anti-freezing function (At standby: Interval 2 seconds, At operation: Interval 0.3 seconds). Blinks during warming up function (At standby: lit on for 0.5 seconds and off for 3 seconds, At operation: interval 0.3 seconds.)

10mA load current) Internal voltage drop Leakage current 100A or less at 24VDC 0.8mA or less at 24VDC Operating position .

Cantilever When the actuator is operated at high speed while it is fixed at one end and free at the other end (flange type, foot type, double clevis type, direct mount type), a bending moment may act on the actuator due to vibration generated at the stroke end, which can damage the actuator.

Vacuum Release Flow Rate Characteristics The graph shows the flow rate characteristics at different supply pressures when the vacuum break flow adjusting needle is open from the fully closed state. ZK2 (Ejector) The actual suction flow at the point of suction varies depending on the piping conditions to the vacuum port. (The above graph shows the value of the ZK2B07) -72No.