A B L L2 MM R1 R2 U L2 MM L1 NDd9 3 NDH10 3 NX Part no.
A B L L2 MM R1 R2 U L2 MM L1 NDd9 3 NDH10 3 NX Part no.
Weight (g)
Rc NPT G 10, 16, 20, 25 32, 40 32, 40 32, 40 TN TG Nil Model/Stroke Bore size (mm) Maximum operating frequency (c.p.m) Open/Close stroke (mm) (L2-L1) Width at closing (mm) (L1) Width at opening (mm) (L2) Weight (g) Model 11221122112211221122112211221122112211221122112211221122112211221122112260 72 94 112 84 126 92 134 172 114 186 340 405 485 660 870 20 40 60 30 60 MHL2-10D MHL2-10D1 MHL2-
Rc NPT G 10, 16, 20, 25 32, 40 32, 40 32, 40 TN TG Nil Model/Stroke Bore size (mm) Maximum operating frequency (c.p.m) Open/Close stroke (mm) (L2-L1) Width at closing (mm) (L1) Width at opening (mm) (L2) Weight (g) Model 112211221122112211221122112211221122112211221122112211221122112211221122MHL2-10D MHL2-10D1 MHL2-10D2 MHL2-16D MHL2-16D1 60 72 94 112 84 126 92 134 172 114 186 340 405 485
HIGH PRECISION DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE50-80, 845, 354.00000 lb
HIGH PRECISION DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE50-80, 845, 338 lb
(m) 1200 1000 400 200 100 -13No.EX-OMN0009-G Power supply connector layout PWR: M12 5-pin plug, A-coded (SPEEDCON) No.
Please refer to an individual catalog for the size when other manifolds are connected. n_m L 0 1 2 3 4 5 6 7 8 L1 45 55.5 66 76.5 87 97.5 108 118.5 129 L2 89.8 110.8 131.8 152.8 173.8 194.8 215.8 236.8 257.8 n_m L 9 10 11 12 13 14 15 16 L1 139.5 150 160.5 171 181.5 192 202.5 213 L2 278.8 299.8 Wiring (for power supply, communication and input) and piping are done on only one side.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
Exterior dimensions C D XMA Series Angle Valve Fd Fn Fc C Fc L1 KF Flange K Flange CF Flange ( K ) ( K F ) ( C F ) L2 H B G A A Unit:mm Model n Fd Fc H P.C.D L1 L2 XMA-16 40 103 38 1 30 34 17 40 P.C.D 27 6x4.4 XMA-25 50 113 48 1 40 26 39 XMA-40 65 158 66 2 55 70 41 63 P.C.D. 58.7 6x6.6 XMA-50 70 170 79 2 75 52 68 XMA-63 88 196 100 3 87 95 114 70 69 P.C.D. 92.1 8x8.4 XMA-80 90 235 117 3 114
M12 32 /NPN() 3 M12 16 /PNP() 4 M12 16 /NPN() MJ CC-Link -8No.EX-OMP0004CN-I
52 66 P 9 11.5 Q 11.5 16.5 R 4.8 4.8 A 4.5 4.5 B 25 34.5 ARM1000 ARM2000 IC ITVH Dimensions by the Number of Stations Manifold stations (n) ITVX Model Symbol 1 36 27 48 39 2 55 46 76 67 3 74 65 104 95 4 93 84 132 123 5 112 103 160 151 6 131 122 188 179 7 150 141 216 207 8 169 160 244 235 9 188 179 272 263 10 207 198 300 291 L1 L2 L1 L2 ARM1000 PVQ ARM2000 VY1 VBA VBAT AP100 753
2 87 100 3 125 138 4 163 176 5 201 214 6 239 252 7 277 290 8 315 328 9 353 366 10 391 404 L1 = 38n + 11, L2 = 38n + 24 n: Station Formula for manifold weight M = 0.16n + 0.1 (kg) 4-16-4
Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70G (0 to 1 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70G (0 to 1 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)