Body Size: 40A, Thread: N (NPT), Port Size: 06 (3/4), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: NRZ (N + R + Z)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: NZ (N + Z)
Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: D [Float Type Auto Drain (N.O.)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: NRZ (N + R + Z)
Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: DG (D + G), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: NRZ (N + R + Z)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: CG (C + G), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: NZ (N + Z)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: N (Stainless Steel Body & Shading Coil, FPM Seal, Class H Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: C (Conduit)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: N (Stainless Steel Body & Shading Coil, FPM Seal, Class H Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Stations: 06 (6 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 06 (6 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp
Stations: 06 (6 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: S (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: LT [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: Yes], Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/
Stations: 06 (6 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: Rc, Port Size: 06 (3/4), Output Specifications: L2 [Out: IO-Link, Switch Output (N/P); Func: Switch Output (N/P); Monitor Unit Model: None], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: Rc, Port Size: 06 (3/4), Output Specifications: L2 [Out: IO-Link, Switch Output (N/P); Func: Switch Output (N/P); Monitor Unit Model: None], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Option 1: N (w/o Lead Wire and M8 Connector)
Body Class: 5 (Class 5, Orifice ø20), Valve Type: 0 (Normally Closed), Port Size: 06 (3/4), Thread: N (NPT), Material: N (Body: PFA, Endplate: PPS, Diaphragm: PTFE, Ammonium Hydroxide Compatible)
Body Class: 5 (Class 5, Orifice ø20), Valve Type: 0 (Normally Closed), Port Size: 06 (3/4, Class 5), Thread: N (NPT), Material: N (Body: PFA, Endplate: PPS, Diaphragm: EPR), Option: 4 (Indicator)
Body Class: 3 (Orifice Diameter ø8), Valve Type: 0 (Normally Closed), Applicable Tube OD: 06 (ø6), Port B OUT: Ports A & B Same Size, Pilot Port: N (Body Class 3, 4, 5, 6 - NPT 1/8"), Material: N (Body: PFA, Actuator Endplate: PPS, Diaphragm: PTFE)
Body Class: 3 (Orifice Diameter ø8), Valve Type: 0 (Normally Closed), Applicable Tube OD: 06 (ø6), Port B OUT: Ports A & B Same Size, Pilot Port: N (Body Class 3, 4, 5, 6 - NPT 1/8"), Material: N (Body: PFA, Actuator Endplate: PPS, Diaphragm: PTFE), Option: 2 (By-pass)