Handle Position: B (Front), Piping: 1 (IN/OUT: Bottom), Fitting: 06 (IN: Straight Ø4, OUT: Straight Ø4)
Handle Position: A (Upper), Piping: 3 (IN:Bottom/OUT:Top), Fitting: 06 (IN: Straight Ø4, OUT: Straight Ø4)
Handle Position: B (Front), Piping: 2 (IN/OUT: Top), Fitting: 06 (IN: Straight Ø4, OUT: Straight Ø4)
Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: Ø6 Plug-In Reducer, Option: -
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: Ø6 Plug-In Reducer, Option: -
Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±1%F.S., Port Size: Ø6 Plug-In Reducer, Option: -
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±1%F.S., Port Size: Ø6 Plug-In Reducer, Option: -
Series PSE digital pressure switches allow pressure to be controlled from a remote location. Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Compact pressure sensor
Series PSE digital pressure switches allow pressure to be controlled from a remote location.? Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Compact pressure sensor
Series PSE digital pressure switches allow pressure to be controlled from a remote location.? Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Compact pressure sensor
Series PSE digital pressure switches allow pressure to be controlled from a remote location.? Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Compact pressure sensor
Series PSE digital pressure switches allow pressure to be controlled from a remote location. Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Compact pressure sensor
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R04 (Ø4 Plug-In Reducer), Output Specification: N (NPN open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 005 (0.5 MPa, −50 kPa, 50 kPa), OUT1 Hysteresis: 5 (0.05 MPa, 5 kPa, 5 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R04 (Ø4 Plug-In Reducer), Output Specification: N (NPN open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 4 (0.04 MPa, 4 kPa, 4 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: P (PNP open collector 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm), Set Value: P (Normal Output), OUT1 Set Value: 007 (0.7 MPa, −70 kPa, 70 kPa), OUT1 Hysteresis: 2 (0.02 MPa, 2 kPa, 2 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R04 (Ø4 Plug-In Reducer), Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 0 (0.00 MPa, 0 kPa, 0 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R04 (Ø4 Plug-In Reducer), Output Specification: N (NPN open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 0 (0.00 MPa, 0 kPa, 0 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: 01 [R 1/8(w/M5 Female)], Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 6 (0.06 MPa, 6 kPa, 6 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: IM5 (M5 Female Thread Through Type), Output Specification: P (PNP open collector 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm), Set Value: P (Normal Output), OUT1 Set Value: 000 (0.0 MPa, 0 kPa, 0 kPa), OUT1 Hysteresis: 1 (0.01 MPa, 1 kPa, 1 kPa)
Model: Branch Tee (Male Thread,Plug-in), Applicable Coaxial Tube: TW06B, Port Tube 1: Rod Ø6, Sealant 1: w/o Sealant, Port Tube 2: Single Tube Ø4, Sealant 2: -