Stations: 10 Stations (Note: 2 Stations are Required for Serial Unit Mounting), Port Size: 03 (Rc3/8), Mounting Base: S (U Side), Kit Type: Q (DeviceNetâ„¢, 16 Output Points), Option 1: SD (Built-in Silencer, Direct Exhaust from D Side)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Q (w/M12-M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Q (w/M12-M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Q (w/M12-M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 2 (Energized Closed/N.O.), Option: Q (Stainless Steel Body & Shading Coil, PTFE (FPM) Seal, Class H Coil), Port Size: 03 [3/8 (10,15A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Q (Stainless Steel Body & Shading Coil, PTFE (FPM) Seal, Class H Coil), Port Size: 03 [3/8 (10,15A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: C (Conduit)
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: Units Selection Function, Calibration Certificate: A (Made to Order)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: Units Selection Function, Calibration Certificate: A (Made to Order)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)
Description Material Note IR Aluminum die-casted Body Bonnet Chamber Valve guide Platinum silver painted Platinum silver painted Platinum silver painted Platinum silver painted In the case of AR825/835/925/935, the material is aluminum alloy. q w e r 1. Release the lock to adjust the pressure. After the adjustment, engage the lock.
None Float type auto-drain 00 11 q Replacement Parts AU100 has no auto-drain type. Element Bowl guard Material Model Port size Description No.
Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 6 8 10 12 Inch sizes 03 05 07 11 13 1/8 3/16 1/4 3/8 1/2 Different diameter tubing order example Basic size With reducer Note) Applicable fitting: LQ2 Different diameter tubing (with plug-in reducer) can be selected within the same body class. (Example) Body class 3 A side: 10 x 8 B side: 8 x 6 Order as shown below.
.:..aiu.lu:.it:rit spqtrcatrons iet pressure max. 0.1MPa 1 a o iet Dressure max. 0.5MPa o a o iet oressure max. 0.9MPa a o )onnection Rc(Pfl 1/4 02 o o o E EE .ti'6 u, at CL ]onnection Rc(PT) 3/8 03 o o )onnection Rc(PT) 12 04 o Bracket B o o Bracket o o @ L-bracket Connection NPTl/4 N02 a o Connection NPT3/8 N03 a o o tr 6 . 9 o u t = ^ O v o EL o Connection NPTl/2 N04 o Connection G(PD
), Bracket: w/o Bracket, CE Compliant: Q (CE Compliant)
Valve Stations: 5 Stations, Port Size: 03 (3/8), Thread: F (G), SI Unit: Q (DeviceNetâ„¢), End Plate Type: 2 (M12 Connector Power Supply, Max Supply Current 2A)
Valve Stations: 4 Stations, Port Size: 03 (3/8), Thread: T (NPT/NPTF), SI Unit: Q (DeviceNetâ„¢), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)
Stations: 8 Stations (Note: 2 Stations are Required for Serial Unit Mounting), Port Size: 03 (Rc3/8), Mounting Base: S (U Side), Kit Type: Q (DeviceNetâ„¢, 16 Output Points), Option 1: CD (Exhaust Cleaner for D Side Mounting), Option 2: W (Dust Poof IP65 Rated)