Body Size: 50, Backflow: w/o Backflow Function, Thread: N (NPT), Port Size: 06 (3/4), Options: BE (B+E), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: N (Non-relieving Type), Flow Direction: Left to Right, Knob: Downward, Pressure Units: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Option 1: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Size: 5 (50), Valve Type: 1 (Normally Closed), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 06 (Thread; 3/4), Thread Type: N (NPT), Rated Voltage: 6 (12 VDC), Electrical Entry: GS (Grommet with PCB, w/ Surge Voltage Suppressor)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal,
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: D (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: D (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp
Size: 5 (50), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 06 (3/4), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: WN (M12 Connector w/o Connector Cable, w/Surge Voltage Suppressor), Oil Free Option: None, Bracket: B (with Bracket)
Size: 5 (50), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 06 (3/4), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: WN (M12 Connector w/o Connector Cable, w/Surge Voltage Suppressor)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: KT (OUT1: Analogue 4 to 20 mA - OUT2: Analogue 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Option 1: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (SI Unit Only)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: DG (D + G), Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: NZ (N + Z)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: D [Float Type Auto Drain (N.O.)], Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: NZ (N + Z)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: D [Float Type Auto Drain (N.O.)], Attachment: S (Pressure Switch), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: NZ (N + Z)
Size: 5 (Body Ported), Pilot: 0 (Internal Pilot), Power Source, Command Signal: 1 (24V, 0~10V), Port Size: 06 (3/4), Thread: N (NPT), Option: N (Silencer)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: N (No Lead Wire), Unit Specifications: Unit Selection Function, Option 2: R (With Bracket)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: N (No Lead Wire), Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: A (NPN; NPN), Option 1: N (No Lead Wire)
Flow Rate Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: N (No Lead Wire)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: Standard, Semi-Standard 1: 18N (1 + 8 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: Standard, Semi-Standard 1: 1N (1 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)