ON = A (A B)/4 A = Max. pressure OFF = B + (A B)/4 B = Min. pressure Perform zero clear operation again after restoring the applied pressure to an atmospheric pressure condition. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.

Series VFR2000 5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in How to Order F: Plug-in type Electrical entry Option Port size (P, A, B port) Thread type Nil F G Rc Nil Z None Nil 01 Without sub-plate 1 8 1 4 With light/surge voltage suppressor 02 N NPT Piping (P, A, B, EA, EB port) T NPTF EA, EB port: Rc 1/8 Nil B Side ported Bottom ported Option SJ 1 00 01 F Plug-in

Metric size Inch size 23 3.22 01 1/8" 03 5/32" 07 1/4" Stud position detail A: Right side B: Left side 04 4 06 6 1 For selecting applicable tubing O.D., refer to the Model on page 2. 2 Use 1/8" tubing. Stud 3

Port size (P, A and B port) Rated voltage M5 01 M5 x 0.8 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 8 R1, R2: M5 Option 24 VDC 12 VDC Nil None With bracket (Not assembled) 240 VAC, 50/60 Hz For other rated voltages, please consult with SMC. F Option Part No. Description Part no.

$% % 33 1 ,) % % 1 ) ,, ) /) H B 7 !"# ! , & Ordering example VX021-001GB-01 !"# $ % & VX021-002DBT-04 ' ( !

$% % 33 1 ,) % % 1 ) ,, ) /) H B 7 !"# ! , & Ordering example VX021-001GB-01 !"# $ % & VX021-002DBT-04 ' ( !

XDD file Model number XDD file 1 EX260-SPL1 F0007_EX260-SPL1.xdd 2 EX260-SPL3 F0007_EX260-SPL3.xdd The network configuration procedure using the B&Rs Automation Studio is described below. 1) Select "Import Fieldbus Device" from "Tools" in the Main menu, and install XDD file.

) Exhaust (OUTEXH) Model IN, OUT EXH C(dm3/s-bar) b Cv C(dm3/s-bar) b Cv VHS20 1/8 1/8 4.0 0.41 1.1 3.7 0.42 1.1 1/4 5.8 0.31 1.4 3.8 0.42 1.1 6 VHS30 1/4 1/4 8.8 0.44 2.4 8.0 0.46 2.3 3/8 14.1 0.28 3.5 7.8 0.46 2.2 1/4 9.5 0.49 2.8 13.3 0.47 3.6 VHS40 3/8 17.2 0.47 4.8 13.6 0.47 3.7 3/8 1/2 26.7 0.29 6.3 13.4 0.43 3.7 -6- 4.

How to Order VR2110 01 Port size 01 Rc1/8 N01 NPT1/8 F01 G1/8 10 5. Operation Patterns ON timing: ON upon the set delay Output method: Normal close Settable time delay: 0.5 to 60 seconds Operation time chart is shown in Fig. 1. Time delay (Input signal) Time (Output) Fig. 1: Operation timing chart When an Input Signal Pressure is provided, Output turns ON after the preset time.

How to Order 10 SY 5 L 5 1 20 01 Clean series Bracket Series Nil: Without bracket F1: With foot bracket A, B port size 3 10-SY3000 5 10-SY5000 Thread piping 2 position single only Coil type Symbol Port size M5 x 0.8 10-SY3000 Applicable series 7 9 10-SY7000 10-SY9000 M5 Standard Nil 1 8 01 10-SY5000 T With power saving circuit (24, 12 VDC only) Actuation type 1 4 10-SY7000 02 02 03 2 position

Example wiring is shown in the figure b. : Bit status 0 and 1 in the data corresponds to solenoid valve status OFF and ON (0: OFF, 1: ON), and the output number starts at zero from LSB (least significant bit). -13No.EX-OME0011-H Maintenance Mounting and wiring Item to inspect Criteria Countermeasure Are SI unit terminals (for communication and power supply) securely connected?

AS120-M5 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 646 B

Element Description EtherNet/IPTM connection PORT 2. 1 (M12 4-pin socket, D-coded) 1 Fieldbus interface connector (BUS OUT) EtherNet/IPTM connection PORT 1. 1 (M12 4-pin socket, D-coded) 2 Fieldbus interface connector (BUS IN) 3 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit. 1 (M12 4-pin plug, A-coded) 4 FE terminal Functional earth.

B [mm] 11 S coupler KK4P-03MS 35.7 H06 Metric size One-touch fitting 6 KQ2H06-03AS 13 H08 8 KQ2H08-03AS 13 H10 10 KQ2H10-03AS 18.4 H07 Inch size One-touch fitting B B 1/4" KQ2H07-36AS 13.4 H09 5/16" KQ2H09-36AS 13.4 H11 3/8" KQ2H11-36AS 18 With S coupler plug mounted (KK4P-03MS) With One-touch fitting mounted (KQ2H AS) -3- 4.External dimensions Long nozzle(Option) L + 7 Reference dimension

Setting using System Manager 1. Copy the XML file *1 for this unit to the following folder: C:TwinCATloEtherCAT (this path is valid only when the default setting is kept.) Start up the TwinCAT System Manager after copying. 1: The XML file for this product can be found on the SMC website (URL http://www.smcworld.com). 2. Network setting 2-1. Off-line manual configuration method 2-1-1.

Element Description PROFINET connection PORT 2. 1 1 Fieldbus interface connector (BUS OUT/Port2) (M12 4-pin socket, D-coded) PROFINET connection PORT 1. 1 2 Fieldbus interface connector (BUS IN/Port1) (M12 4-pin socket, D-coded) 3 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit. 1 (M12 5-pin plug, A-coded) 4 FE terminal Functional earth.

Example wiring is shown in the figure b. : Bit status 0 and 1 in the data corresponds to solenoid valve status OFF and ON (0: OFF, 1: ON), and the output number starts at zero from LSB (least significant bit). (3) Fuse disconnection details The power supply fuse disconnection for the SI unit solenoid valves can be monitored by the link special register of the master station. 0: Normal 1:

robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4

-100 kPa 100 kPa For positive pressure -0 to 1 MPa 0 1 MPa -0.1 MPa -13No.PS-OMG0004-D Dimensions PSE54(A)M3 M5 PSE54(A)-M3 PSE54(A)-M5 A 10.8 11.5 B 3 3.5 PSE54(A)01 N01 PSE54(A)R04 R06 PSE54(A)-R04 PSE54(A)-R06 A 4 6 B 18 20 PSE54(A)-IM5 PSE54(A)-IM5H -14No.PS-OMG0004-D Revision history A: For B: Complete revision C: Limited warranty and Disclaimer and measurement laws are added.

Compact Direct Operated 2 Port Solenoid Valve for Water and Air SeriesVDW10/20/30 VX2 How to Order Valves (Single Unit) VXD For Water, Air, Vacuum VD W 2 1 1 G 2 01 VXZ VXE Made to Order (Refer to page 244.) Series VXP 1 2 3 10 N.C.