Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread)
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.
Nil With power supply cable (3 m) IZN10E-CP Z With power supply cable (10 m) IZN10E-CPZ N Without power supply cable * Mounting is interchangeable with the current model (IZN10).
10 0 10 20 30 0 20 40 60 Work load (W) kg Work load (W) kg Work load (W) kg 600 600 600 L2 M2 400 400 400 L2 mm L2 mm L2 mm Rolling Yawing W 200 200 200 L2 M2 0 10 20 30 0 20 40 60 0 2 4 6 8 10 Work load (W) kg Work load (W) kg Work load (W) kg W 3000 2000 2000 a=1000 a=1000 a=1000 2000 L3 mm L3 mm L3 mm L3 1000 1000 1000 a=2000 a=2000 W a=2000 a=3000 a=3000 a=3000 M3 a 0 20 40 60 0 2 4
DC 0.35 W DC 0.1 W DC (at holding) with power saving circuit Note 1) VZ VS VFN Note 1) With the 0.1 W DC specification, keep the vibration/impact within10/50 m/s2. 0.35 W DC at inrush (20 ms) and 0.1 W DC at holding.
Remarks Lead wire and M12 connector (3 m) Straight ZS-37-A 1 pc. Lead wire and M12 connector (3 m) Right angle ZS-37-B 1 pc. Connector for pressure sensor controller ZS-28-CA-4 1 pc. Adapter with throttle Rc1/4 ZS-31-X175 1 pc.
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.
Do not use a cable longer than 10 m. Consult with SMC for the use with a cable longer than 10 m.
Recommended tightening torque [N-m] Thread 1/8 Torque 7 to 9 Do not apply any additional twisting, or bending moments except for the weight of the filter regulator itself. Provide separate support for external piping, as damage may otherwise occur.
Nil (Example) C73C 3 m L (Example) H73CL 5 m Z (Example) C73CZ None N (Example) C73CN Since there are other applicable auto switches than listed, refer to page 9-4-10 for details.
How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
Plug-in sub-plate (With terminal block) V Remove junction cover q of sub-plate where terminal block box w is mounted. Non-locking push style Bore 5 Push down on the manual override button with a small screwdriver until it stops.