Stations: 3 Stations, Port Size: 03 (Rc3/8), Thread Type: N (NPT), Kit Type: 2 (3.0m Cable)
Stations: 10 Stations, Port Size: 03 (Rc3/8), Thread Type: T (NPTF), Kit Type: 2 (3.0m Cable)
Stations: 5 Stations, Port Size: 03 (Rc3/8), Thread Type: Rc, Kit Type: 2 (3.0m Cable)
Stations: 3 Stations, Port Size: 03 (Rc3/8), Thread Type: T (NPTF), Kit Type: 2 (3.0m Cable)
Valve Stations: 5 Stations, Port Size: 03 (3/8), Thread: T (NPT/NPTF), SI Unit: Q (DeviceNetâ„¢), End Plate Type: 2 (M12 Connector Power Supply, Max Supply Current 2A), SI Unit COM: N (-COM)
Stations: 2 Stations, Port Size: 03 (3/8), Thread: Rc, S Kit: SEA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12)
Stations: 2 Stations, Port Size: 03 (Rc3/8), Thread Type: F (G), Kit Name: FD3 (D-sub Connector 25 Pin 5.0m)
Stations: 2 Stations, Port Size: 03 (Rc3/8), Thread Type: F (G), SI Unit: SD0A (w/o SI Unit)
Size: 60, Base Dew Point: H (-15°C), Type: Standard, Equipment Connection: 2 (Nipple Connection), Thread: Rc (PT), Port Size: 03 (3/8), Draining: D (N.O. Auto Drain), Option: P (Fitting for Purge Air Exhaust)
Stations: 2 Stations, Port Size: 03 (Rc3/8), Thread Type: T (NPTF), Kit Name: FD1 (D-sub Connector 25 Pin 1.5m)
Stations: 2 Stations, Port Size: 03 (Rc3/8), Thread Type: Rc, SI Unit: SD0A (w/o SI Unit)
Stations: 03 Stations, Port Size: N7 (w/ø1/4" One-Touch Fitting), SI Unit: 0 (w/o SI Unit), End Plate Type: None, SI Unit Common: + COM (or None in the Case of w/o S/I Unit), I/O Unit Stations: None, Option 1: None, DIN Rail Length: None, Option 2: S (Built-in Silencer, Direct Exhaust)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 300mm), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: N (NPT)
Function: 4 (3 Position Exhaust Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: YO (DIN EN175301-803 Terminal w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03
Body Size: 25, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: DG (D + G), Attachment: SV (S + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 25, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: SV (S + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min;
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes]