SMC Corporation of America
Elite Part Number Search
Search Results "AWD40-N04-12Z-D"

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Pressure relief, 3 port valve, Accessory for AC series, Body sizes: 1/8

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Pressure relief, 3 port valve, Accessory for AC series, Body sizes: 1/8,

Combining a mist separator and regulator into one unit simplifies piping and installation. This combination controls the filtration to 0.3µm, for applications that require cleaner air than regular filtration, such as air blow off. As part of the family of modular air preparation units, the AWM can be combined with other similar sized products. This series is available with port sizes from

Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: P (Stop Valve), Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: E (Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None), Lead Wire: N (without Lead Wire), Flow Switch Unit: J (Integrated Display; Instantaneous Flow: L/min; Accumulated Flow:

Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5~40L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: E (Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None), Lead Wire: N (without Lead Wire), Flow Switch Unit: J (Integrated Display; Instantaneous Flow:

Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: E (Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: J (Integrated Display; Instantaneous

Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: E (Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None), Lead Wire: N (without Lead Wire), Flow Switch Unit: J (Integrated Display; Instantaneous Flow:

Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5~40L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: E (Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: J (Integrated Display; Instantaneous

Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: FT (Integrated Display; Out 1: PNP; Out 2: (Analog 4 to 20 mA) ⇔ Analog 4 to 20 mA ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: F (Integrated Display;

Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: None, Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: FT (Integrated Display; Out 1: PNP; Out 2: (Analog 4 to 20 mA) ⇔ Analog 4 to 20 mA ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: M (Integrated Display, IO-Link Campatible; Instantaneous

Series AN silencers offer various styles and low backpressure in a compact, easy mounting design. The noise reduction has been improved to 30 dB(A) and the case is UL94-V0 grade, flame resistant material. Series AN is available with M, R or NPT threads. Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960

Size: 41 (1/2), Model Combination: AF+AR+AL, Port Size: 04 (1/2, Size 41), Accessory: None, All Sizes, Pressure Relief Valve: V (Downstream Valve), Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41), Handle Orientation: A (Upward Handle)

Membrane air dryer series IDG is available in a single unit or combination unit style. IDG/M models combine a mist separator and micro mist separator with a single unit. IDG/V models combine a regulator with the IDG/M model. Options available include one-touch fitting exhaust of purge air. If purged air is not exhausted around membrane air dryer, air is exhausted with tubing away

Body Size: 40 (1/2), Port Thread: N (NPT), Port Size: 04 (1/2, AVL4000), Option: No Gauge, Voltage: 5 (24VDC), Electrical Entry: DZM (D Type DIN Conn. w/M12 Conn., Ind. Light & Suppressor), Air Direction: R (Right to Left), Button Color: X238-Q (Black, CE Marked, Electrical Model)

Body Size: 40 (1/2), Port Thread: N (NPT), Port Size: 04 (1/2, AVL4000), Option: No Gauge, Voltage: 5 (24VDC), Electrical Entry: DZ (D Type DIN Connector w/Indicator Light & Suppressor), Air Direction: R (Right to Left), Button Color: X238-Q (Black, CE Marked, Electrical Model)

Flow Switch Type: Integrated Display, Rated Flow Range: 2~16L/min, Return Unit: Stop Valve, Thread: NPT, Port Size: 1/2, Flow Switch Output: Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None, Lead Wire: without Lead Wire, Flow Switch Unit: Integrated Display; Instantaneous Flow: L/min; Accumulated Flow: L; Temp: °F

Flow Switch Type: Integrated Display, Rated Flow Range: 5~40L/min, Return Unit: Flow Adjustment Valve + Stop Valve, Thread: NPT, Port Size: 1/2, Flow Switch Output: Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None, Lead Wire: without Lead Wire, Flow Switch Unit: Integrated Display; Instantaneous Flow: L/min; Accumulated Flow: L; Temp:

Flow Switch Type: Integrated Display, Rated Flow Range: 2~16L/min, Return Unit: Flow Adjustment Valve + Stop Valve, Thread: NPT, Port Size: 1/2, Flow Switch Output: Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None, Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: Integrated Display; Instantaneous Flow: L/min; Accumulated

Flow Switch Type: Integrated Display, Rated Flow Range: 2~16L/min, Return Unit: Flow Adjustment Valve + Stop Valve, Thread: NPT, Port Size: 1/2, Flow Switch Output: Integrated Display; Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V, Temp. None; Temperature Sensor: None, Lead Wire: without Lead Wire, Flow Switch Unit: Integrated Display; Instantaneous Flow: L/min; Accumulated Flow: L; Temp: