Size: 60, Voltage: Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ, Options: w/Heavy-duty Auto Drain, Max. Operating Pressure 1.6 MPa
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø6, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.05 to 5 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.3 to 25 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.05 to 5 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: None (Straight), Port Size: G1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø4, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/4, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.05 to 5 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø6, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/4, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Table Accuracy: Basic Type, Max. Rotating Torque: Basic, 6.6 N.m, Rotation Angle: 320°, Motor Cable Entry: Entry Left Side, Actuator Cable Type, Length: 5m, Controller: Ether Net/IP™, Mounting: DIN Rail, I/O Cable: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left